No Value Area Calculation

No Value Area Calculation

No Value Area Calculation Interventional Radiography: Cardiac Condition ? Post Ventricular Angio Cardiac Ditgot Tharma 3.20 U/min Site DN 02 Sat Ste DN 02 Sat Valve/sat. Difference Gradient Area 123 2 Aartic 3.01 82 1. Valve gradients are calculated using either Pullback or using two Simultaneous pressures Confiar outgut x 3000 Valve area (cm2)= 50Px Comt. x 445 & VEGGIWAT DFT can be used instead of SEP. Const .= 0.85 for mitral valve and for special gradients with the following site combinations: PCW and LV, PV and LV, LA and LV. Const .= 1.0 for other valves 2. Check that the correct CO method (Fick or TD) is selected under Pressure Calculation Settings. Right click on the Pressure Calculation icon after transducers are balanced to go to Pressure - Calculation Settings. Can also go to Tools > - Pressure calculation settings. 3. CO must be entered under same condition as the Gradient. When you change conditions check the inherit CO box on the bottom of the new condition dialog box. 4. If you forget to inherit the CO: Click Input > mout Tools Options Help Condition > Edit Attributes. Then check the Q2 Saturation Cardiac Output Inherit CO box on the new condition dialog box. HB 02 Consumption Vital Signs Condition Documentation Tool Edit Attnbutes 5. Always turn the Recorder On when performing gradient measurements. When performing a pullback, make sure you have at least six beats for each site on the dialog screen. 6. FYI: If the valve Gradient is 0, there is no valve Area because the valve is considered normal. SIEMENS siemens.com/healthineers Healthineers . Job Aid | No Valve Area Calculation Effective Date: 09/08/2016 | Quality HOOD0516200130048 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright @ Siemens Healthcare GmbH ...... ........... Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 2 of 2

  • Angiography/Interventional Imaging
  • Angiostar
  • Artis zee
  • Artis Zeego
  • Axiom Artis