Offline eADC Map - Numaris X
This Job Aid provides workflow instructions on how to calculate an Offline eADC (exponential) Map on Numaris X.
Offline eADC Map – Numaris X Job Aid Offline eADC Map – Numaris X This Job Aid will provide workflow instructions on how to calculate an Offline eADC (exponential) Map on Numaris X software. Inline eADC Maps are also available on the Diffusion Parameter Card, check the box “Exponential ADC Maps” to create an automatic Inline eADC Map. eADC Map – Offline Calculation 1. Open Patient Browser a. Select Patient Folder b. Select Trace Series with 2 b-values c. Load images to View&GO icon Meduser - ? H O & " Brain Dot Engine - 7/1/1987 M 2020.07.01-00:45:27-STD-1.3. Patient Browser Local Data Search by Name ID. Date. Description and Modality (Ctrl+F) Q More Filters Open Operntes Dieal red E Results (82 results, 1:57:02 AM) Series Patient Name Patient ID Date of Birth Study Date an ... Study Descript ... Accession Nu Workflow Study Archived Correc + Series Number Series Description Modality # Instances in .... Series Ard + Sola Elbow Siemens MAC 1/1/1979 7/18/2019 1 Pathology_U. XA20A (2_space_sag_cs4.1 iso MR Sola fit Abdomen Belgium MAC 1/1/1947 9/4/2019 8.2 Lesions Pne. XA20A 6 12_space sag_p2_iso MR GO Livar R XADO 11 resolve_4scan trace tra p2 s2 TRAC. MR Sola Head mens MAC 1/1/1960 6/13/2019 2 Turbo Exami .. XA20A Sola Head 13 MR Sola Heart Stem resolve_4scan trace tra_p2 TRACEW Siemens MAC 1/13/1963 10/24/2019 1 Cine Taggin XA20A Tesoive ascan trace Ura_pz AUC Sola Hip Belgium MAC 1/1/1997 9/10/2019 2 CS-SPACE XA20A 15 12_space_dark-fluid_sag_cs5.8 MR Sola Hip Siemens MAC 1/1/1944 6/27/2019 3 Prosthesis C XA20A 16 12 space dark-fluid sag_p2 MR 2. MR View&GO a. Ctrl + Left Mouse > drag each Diffusion Series into an image segment i. (e.g., 0, 1000) b. Ctrl + Left Mouse > select Both Series (Segments) i. b-Value [b1000] > then b-Value [b0] SIEMENS Healthineers Meduser + ? H 0 & I O Sola_Head * 1/1/1960 F Siemens_MAC MR View&GO ALF Series Sola_Head Siemens Healthineers Sola_Head Siem Siemens Healthingers MR View/&GO SLACK 212 SLACK 544 Siemens_MAC Ref.: Marketing Siemens_MAC Ref: Marketing *1/1/1960, F, 59Y MAGNETOM Sola +1/1/1960, F, 59Y MAGNETOM Sola Mas Study Sonder CURRENT MR XA20 MR XA20 6/13/2019 HFS CURRENT +LPH 6/13/2019 HFS +LPH Series Name resolve_4scan_trace_trap2 TRACEW resolve_4scan_trace_tra_p2_TRACEW latestB-Value_01 latest/B-Value_02 Current XA20A # XA20A STUDY ID 1 aaaa 2910 STUDY ID 1 aaaa2910 MR. 6/13/2019 Favorite Tools 2:44:02 PM 2:45:37 PM 13 IMA 1 FRM 12/22 13 IMA 2 FRM 12/22 RFA RFA Please drag data from Series Navigator. 13 resolve 4scan trace tra_p2 SL 5.0 SL 5.0 B-Value 01 [b0] SPC 6.5 SPC 6.5 B-Value_02 [b1000] TR 5320.0 DIR TE 72.2 TP O TR 5320.0 TP O TA 02:41 SP H39.2 TE 72.2 TA 02:41 SP H39.2 BWV 814.0 FoV 230-230 FoV 230*230 384 384 1 BW 814.0 p2 MAGN/DIFFITRACEWINORMIDIS2 384*384 1 Series ag(7)>Cor(1) p2 MAGN/DIFF/TRACEWINORM/DIS2D Tra>Sag(7)>Cor(1) A1/FS Zoom 1.12 A2/FS Zoom 1.12 HE1-4;NE2 909 HE1-4;NE2 W 478 Fre_b0 / 180 445 *re_b1000t/ 180 221 Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 02/24/2021 | HOOD05162003170435 Healthineers Job Aid | Offline eADC Map – Numaris X Effective Date: 02/24/2021 | HOOD05162003170435 3. Select Favorite Tools a. Select + (opens Tool Gallery) b. Select MR Calculation > Division Icon Division c. Close Tool Gallery > Select X Favorite Tools X 3D Position Display Position Position Mosaic compon New New Display Displ ... Compose Combine Show in ADC & b- New New 3D value Compose Combine MR Calculation + X Subtract .. Addition Multiplic .. Division Mean Correction ADC & b- value Distort Imager Smooth Postprocessing 3D Ref. Distance Position Snapshot Print Stack 3D Point Line Displ. RIA Flip Save as Mosaic Subtract ... Horizontal Series + 4. Create Division Window a. Settings > MR Division Settings (Default) b. Dividend > b-1000 Series (check if loaded) Create Division ? X c. Divisor > b-0 Series (check if loaded) Settings MR Division Settings Config . Dividend resolve_4scan_trace_tra_p2_TRACEW. latest.B-Va Remove Divisor resolve_4scan_trace_tra_p2_TRACEW.latest .. Use Constant 1+ Result Series Name Results DIV_P1_resolve_4scan_trace_tra_p2_TRACE OK Cancel Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 02/24/2021 | HOOD05162003170435 Healthineers Page 2 of 5 Job Aid | Offline eADC Map – Numaris X Effective Date: 02/24/2021 | HOOD05162003170435 d. Select Configuration Icon Config. e. Division Settings window Division Settings ? × i. Factor > set to 1000 ii. Select OK MR Division Settin ... Name of Settings MR Division Settings Offset Factor 1000 Maximum 4095 Minimum 0 Use Constant Default Add Duplicate OK Cancel f. Create Division window i. Results Series Name > Enter eADC Map ii. Select OK > eADC Map created Create Division ? X Settings MR Division Settings Config . Dividend resolve_4scan_trace_tra_p2_TRACEW.latest.B-Va Remove Divisor resolve_4scan_trace_tra_p2_TRACEW.latest .. Use Constant Result Series Name eADC Map OK Cancel Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 02/24/2021 | HOOD05162003170435 Healthineers Page 3 of 5 Job Aid | Offline eADC Map – Numaris X Effective Date: 02/24/2021 | HOOD05162003170435 5. eADC Map Image ALF a. Window Image 1aaaa2910 FRM 12/22 JAVAILIDIVINORMIDIS2D lve_4scan_trace_tra_p2_TRACEW[1]/resolve_4scan_trace_tra_p2_TRACE 6. Save eADC Map to Patient Browser a. Select Save and Send – results are stored on system and send to archive b. Select Save – results are stored on the system II Save and Send Save Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 02/24/2021 | HOOD05162003170435 Healthineers Page 4 of 5 Job Aid | Offline eADC Map – Numaris X Effective Date: 02/24/2021 | HOOD05162003170435 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 02/24/2021 | HOOD05162003170435 Healthineers Page 5 of 5
- MR
- eADC
- Map
- Numaris X