Overlay Reference (VC21 to VD11)
Job aid highlighting steps to perform Overlay Reference.
Overlay Reference (VC21 – VD11) Job Aid Advanced Therapies – Artis Software VC21 to VD11. **There is an additional job aid availa- ble on PEPconnect to determine SW version of the system. Overlay Reference, a.k.a Fluoro Fade, Overlay Ref or Reference Overlay, allows user to overlay a reference image onto the LIVE fluoro image. The reference image can be created from a Store Fluoro, a DSA acquisition, a DR acquisition and can even contain post processing and graphics. Graphics WILL be displayed as part of the Overlay Reference. 1. Select an image and store as reference onto the Assist or Reference monitor. It does not matter which monitor is used. The active monitor, if it has an image displayed, will per- form Overlay Reference. To change to a specific monitor, use the REF/AS icon on the touch screen or in the control room in the Examination taskcard. REF AS Storing a reference image can be performed from the touch screen joystick middle mouse button at table side or the Store Reference icon on the touch screen. It can also be stored Store Reference icon from the control room in the Examination taskcard. REF Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/02/2020 | HOOD05162003101541 Healthineers Job Aid | Overlay Reference Effective Date: 07/02/2020 | HOOD05162003101541 2. Select the Overlay Ref icon from the touchscreen or the control room Examination taskcard. The icon will turn white with a green joystick symbol in the upper left corner. REFOS REFO This green symbol lets the user know that the joystick will control the fading function. If the green symbol is not displayed, Overlay Ref is still active, but the joystick does not con- trol the fading in and fading out of the overlay. Select the Overlay Ref icon once again to assign fading function to the joystick. Settings Exam Quant Physio 4D ? Exam Set A E A+B 000.0 FL(-) Neuro SM Fluoro Prog. Acq. Prog. kV 81.0 DSA 40.0 REF 15 p/s 3 f/s mA A ms 5.7 REF Cu mm 03 AS RDMP RDMP B p/s 4 p/s 3. Step on fluoro. User will now see the reference image displayed onto the LIVE fluoro im- age as an overlay. ADERN RAO: 0 CAUD: Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/02/2020 | HOOD05162003101541 Healthineers Page 2 of 4 Job Aid | Overlay Reference Effective Date: 07/02/2020 | HOOD05162003101541 4. The overlay percentage on the LIVE fluoro image can be adjusted by using the joystick. By moving the joystick up and down, the overlay percentage can be faded in or faded out. The overlay can be adjusted while on or off fluoro. The overlay percentage number will display on the lower right corner of the Live image. If there are graphics displayed, the graphics are NOT affected by the overlay percentage. The graphics remain visible at all times until Overlay Ref is deactivated. Remember, the touch screen joystick controls the overlay image % only when the icon displays the green joystick symbol. See step 2. Notes: • Automap can be used with Overlay Reference • Bones are still visible, not a subtracted overlay • No extra roadmap functions available with Overlay Reference • Overlay Ref images can also be stored as a Store Fluoro and a Store Monitor ADERN ADERN RAO : RAO: 0 CAUD: Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/02/2020 | HOOD05162003101541 Healthineers Page 3 of 4 Job Aid | Overlay Reference Effective Date: 07/02/2020 | HOOD05162003101541 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter co llectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written auth ority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/02/2020 | HOOD05162003101541 Healthineers Page 4 of 4
- Overlay Reference (VC21 to VD11)