PEPconnect

ACUSON P500 Smart Cart Overview Video

Instructional video provides an overview for the ACUSON P500 ultrasound system Smart Cart.

This training program is designed to provide you with an overview of the acuson P500 ultrasound system components, controls and basic operation. In this section we will give you an overview of the acuson P 500 system smart card. The smart cart has four locking brakes. Each brake has a locking lever Anna release lever. To lock the front wheels, press the larger locking level located next to the wheel downward with your foot. When the lock is engaged, the release lever moves upward. Each wheel has locks that lock and unlock independently to unlock the front wheels. Press the release lock down. The height of the smart cart can be adjusted by pressing the lever located underneath the cart handle and pulling the handle upward or pushing the handle downward. The maximum height of the smart cart ranges from 89 to 109 centimeters, or 35 to 42 inches. The cart is 59 centimeters or 23 inches wide, 79 centimeters or 31 inches deep, and weigh 64 kilograms or 141 pounds. The Acuson P 500 system smart cart multiple transducer module or M TM supports a versatile family of high performance curvi linear linear and phased array transducers. The MTM has three active image Ng ports. To connect the transducers to the smart cart. In short, the transducer lock is in the unlock position. Gently insert the transducer connector into the port and press the lever to the left to remove the transducer. Press the lever to the right and gently pull the connector from the port. The smart cart has transducer holders on each side. These can also be used as gel bottle holders. Hooks provide support for transducer cables. Keep the cables off the floor and help prevent tangling of the cables. To remove the acuson P 500 system from the smart cart, disconnect devices and cables from the system. This includes the MTM transducers, power cable and any peripheral devices the locks are located at the back and underneath the smart card. Push the lock on the right side toward the left side of the system. Then pull and hold the lock on the left side of the system. Tored the left as you disengage the acuson P 500 system from the cart. Placing the acuson P. 500 system on the cart begins by aligning the ultrasound system with the top of the cart press down firmly until you hear a click. Pull the lock located on the right side of the cart towards the right until you hear a Click to lock the acuson P 500 system. When the acuson P 500 system is correctly logged onto the smart cart, the battery indicator located at the top of the monitor or by the front handle blinks. A solid light indicates the system is running on battery power and improperly connected to the smart cart. Please note right lever located on the underside of the system must be fully pulled outwards to the right for the battery to charge. Instructions for connecting and disconnecting the acuson P 500 system. From the smart cart are located at the back of the cart. Printers that are no more than 20 kilograms or 44 pounds can be placed on the upper an lower shelves of the smart card. These USB printers connect to the accessory power located in the lower back of the smart card and USB ports located on the left side of the system. The lower shelf also has a drawer for storage of supplies. On the back of the smart cart there are input output connections. These include an HDMI port, Ethernet port and DC out port. The HD MI port allows for connection of the smart cart to a secondary monitor while the Ethernet port connects the cart to a network. The DC outport is the location to connect an exhilarate ECG. During transport or storage, the smart cart power cord can be stored on the back of the system or in a drawer located at the base of the smart cart. To clean the smart card, begin by powering off and removing the acuson P 500 system. Unplug the smart card, lightly. Moisten a clean gauze pad or lint free cloth with mild detergent or an approved disinfectant. Refer to the user manual for approved list of cleaners. To clean the transducer Holder, press the tab located on the inside of the Holder and pulled down to remove the Holder. Place the liner under running water. Clean with a mild detergent and dry with a lint free cloth. When dry, insert into the transducer Holder refer to transducer acuson, P 500 system disinfectant guide for approved cleaners. The USB dual pedal footswitch connects on the left side of the system. The Footswitch has two petals. Each pedal corresponds to a function that can be assigned in the custom keys tab in the configuration menu.

ACUSON P500 The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be с асса а 202' •сссссс есс.•сссссс с ссссс•• с с с с liable for damages. .ГО •сссссс го •сссссс •сссссс сассса• •ccccczc •сссссс••• •СССССС весс.•сссссс• Baseline Scale Height: сааааа• All names and data of patients, parameters and configuration dependent designations are fictional and examples only. •сссссс• с ссасс 89 - 109 cm •сссссс• All rights, including rights created by patent grant or registration of a utility model or design, are reserved. •сасссс• аааааа• •cccccc бое •ссссас зов •сссаас (35 - 42 inches) ••бОе •сссссс сааааа• асса а а • сапа а а • с асса а • Please note that the learning material is for training purposes only! сапа аз • ECG For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator ACUSON SIEMENS Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator ••••сспссса •••••сссаааа Width: Depth: Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software 59 cm (231 inches) and hardware available at the time of the training. сн5-2 ACUSON P500 ultrasound system Siemens Healthineers presents The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Healthineers Note: Some functions shown in this material are optional and might not be part of your system. The information in this material contains general technical descriptions of specifications and options as well as standard and optional features that do not always have to be present in individual 79 cm (31 inches) cases. Certain products, product related claims or functionalities described in the material (hereinafter collectively "Functionality') may not (yet) be ОШТРИЈТ ОШТРИТ О(ЈТРИТ ОИТР(ЈТ OUTPUT commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not ОШЈТРИТ ОС 0.5А guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. ос ОС DC 0.5A ОС 12V:— 0.5А Height: ОС 0.5А 4- ACUSON "500 is a trademark of Siemens Medical Solutions USA, Inc. 64 kg (141 pounds) 64 kg (141 pounds) 4- нат: Chapter 1 - Smart Cart Overview [email protected] Siemens Healthcare GmbH, 2020 Effective Date: 26-May-1 6 - HOOD05162002265483

  • Interventional Cardiology
  • Interventional Radiology
  • Critical Care
  • Liver Disease
  • Oncology
  • Surgery
  • Urology
  • Ultrasound
  • Interventional Cardiology
  • Interventional Radiology
  • Critical Care
  • Liver Disease
  • Oncology
  • Surgery
  • Urology
  • Ultrasound
  • POC
  • Point of Care
  • Trauma
  • FAST
  • eFAST
  • BLUE
  • FOCUS