PURE Aortic Valve Guide Workflow
PURE Aortic Valve Guide Workflow
Aortic Value Guidance for PURE Interventional Radiography: Cardiac 1. Cardiac DynaCT is acquired and loaded into the 4D task card. NOTE: This step is no longer required; you may load a previous dataset and follow the steps for 2D/3D or 3D/3D fusion. 2. Select Aortic Valve Guidance from the workflow drop down if it didn't load automatically. 3. Aortic root is segmented out automatically. A AVG case1 HLP TDC Cary A AVG_case1 123456 AXIOM Artis 123456 Angio Nat Fill HU Norma ... VC13D 081121-2 VB13F Argio Nat Fill HU Norma ... *12/6/1927 HFS 212/8/1927 XA 1/28/2011 1/28/2011 10:54:07 AM 10:54:07 AM ALF Plan? SL 33.0 BL 13.0 1458. MIP Thin MIP Thin LAO 105 / CAUD 44 LAO 57 / CRAN 35 A AVG caso LAH TDC Cary A AVG case1 HILA 123456 AXIOM-Artis 123456 G AXIOM-Artis Angio Nat Fil HU Norma VC13D 081121-2 VB13F Angio Nat Fil HU Noma VC13D 081121-2 VB13F 12/6/1927 HFS *12/6/1927 HFS XA XA 1/28/2011 1/28/2011 10:54:07 AM 10:54:07 AM RAH A Plane SL 18.0 MIP Thin 1498 VRT 821 811 LAO 165 / CRAN 26 LAO 17 / CAUD 13 SIEMENS siemens.com/healthineers Healthineers Job Aid | Aortic Valve Guidance for PURE Effective Date: 08/17/2016 | Quality HOOD05162002269998 4. Check results, modify display, and correct positions of markers. a. Correct position of any marker by left clicking, drag and drop, in any MPR or VRT view b. Modifying Display can be achieved using the selections below Review and Processing Aortic Valve Guidance × Valve planning / sizing Analyze and Overlay Verify analysis results. Adjust C-Arm to volume and perform X-ray. Show Object Group 111 Contour Centerline Commissure Lines -- SHIDESURF SHADE SURF 2345 3/2278900- LACIRAD LACRAD CRANICAUD CRAUCAUD VOOMANS 23/2008 09:46.07 AK R A A 100 W/ 2829 B 100 W 2829 C 1528 C 1628 5. Perform 3D overlay functionality. Siemens Healthineers Services Page 2 of 3 Job Aid | Aortic Valve Guidance for PURE Effective Date: 08/17/2016 | Quality HOOD05162002269998 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright @ Siemens Healthcare GmbH ...... Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 3 of 3
- Angiography/Interventional Imaging
- Artis One
- Artis Q
- Artis zee
- Artis Zen