RAPIDPoint® 500e Blood Gas System Calibrate the Touch Screen Job Aid
This job aid provides instruction on how to calibrate the touch screen.
Calibrate the Touch Screen RAPIDPoint® 500e Blood Gas System Refer to the Operator’s Guide when performing the following procedure. Calibrate the touch screen if it responds inconsistently to touches. For example, if you must touch to the right or the left of an item to select it. Only operators with level 1 security access can calibrate the touch screen. 1. If prompted, enter your password, or your password and operator ID 2. Select the System button 3. Select Setup Status 13:43 ? 07/01/2019 Cartridge Status 2 Replace Analyzed 4 4 Days Remaining 23 5 Replace Port Exp. Date 07/25 07/07 Exp. Time 08:54 08:54 Events Log Shutdown Clean Screen Calibrate 3 System Info ... Setup Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/11/2019 | HOOD05162002998095 Healthineers Job Aid Effective Date: 30/Mar/2020 | HOOD05162003076203 Job Aid | Calibrate the Touch Screen Effective Date: 30/Mar/2020 | HOOD05162003076203 4. Select Secured Options 5. Select Screen Calibration The Calibration screen appears with the Target button in the upper left corner of the screen O Touch button. 6. Touch the button that appears in the upper left corner of the screen 7. The button disappears for two seconds, then reappears in the lower right of the screen 8. Touch the button again when it appears on the screen. The system returns to the Setup menu when the touch screen is calibrated 9. Select the Continue button twice to return to the Analysis screen Caution: Touch only the button that appears on the screen, and touch this button only once each time it appears. Touching any other part of the screen or touching the button more than once causes the screen to become inoperable. If this occurs, call for technical assistance. Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Page 2 of 3 Job Aid | Calibrate the Touch Screen Effective Date: 30/Mar/2020 | HOOD05162003076203 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. RAPIDPoint is a registered trademark of Siemens Healthcare Diagnostics. Copyright © Siemens Healthcare GmbH 2020 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Page 3 of 3
- Rapid point
- Rapid Comm
- blood gas
- calibrate
- window