RAPIDPoint® 500e Blood Gas System Positioning a Syringe in the Sample Port
This video provides instructions on how to perform the task of positioning a syringe in the sample port on the RAPIDPoint® 500e Blood Gas System.
View the following video before you begin to run a syringe sample. Properly collect, mix and transport the syringe sample from the patient to the blood gas system. Select the syringe button. Mix the syringe sample. Remove the filter cap, expel the first drop into a gauze pad and insert the syringe into the sample port. Select the start button, wait for the sample to aspirate. The sample port will return to its original position after the sample has aspirated. Remove the syringe from the sample port, press continue. And replace the filter cap on the syringe scan patient ID. And select the continue button to initiate the sample analysis. Play the video again if you need help running a syringe sample.
The system is temporarily busy. Please wait. Autom @ 2019 Siemens Healthcare Diagnostics Inc. All rights reserved. RAPIDPoint and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc., or its affiliates. 01 : 14 01 Ready 14 01 Analyzing All other trademarks are the property of their respective owners. 12/147018 Autom 2018 SIEMENS. . Please note that the learning material is for training purposes only! MALARNEY 01626374 01626374 Na• pH Glu Patient ID For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively pH SIEMENS SIEMENS . i.165 Na• pH "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means pco: pcoa Lac 68.7 pcoz mmHg mmol/L p 02 Last Name substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily '53.3 mmHg 0-1492317 Cl- HCO,-act reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as mm/dd/YYYY BE(8) mm/dd/yyyy p02 tHb BE(B) mmol/L Date of Birth your main reference, in particular for relevant safety information like warnings and cautions. mng/dL Glu FHetHb Healthineers ' Glu 80.5 Cl- (Optional) nBili mng/'dL -act Hect Automatic QC Note: Some functions shown in this material are optional and might not be part of your system. 12.07 Lac rnrnOl/L FCO Hb mmol/L FCOHb Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially FHetHb 3.64 Effective Date January 2, 2019 available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not HILS/ HOOD05162002958764 2063 mg /dL Clear nBili guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. Remove syringe RAPIDpoint sooe Copyright @ Siemens Healthcare GmbH 2019 SIEMENS. • Clear All The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Healthineers ' Healthineers Start Global Siemens Healthineers Headquarters Offenders will be liable for damages. Henkestr. 127 91052 Erlangen, Germany 91 052 Erlangen, Germany All names and data of patients, parameters and configuration dependent designations are fictional and examples only. Phone: +49 9131 84 All rights, including rights created by patent grant or registration of a utility model or design, are reserved. siemens.comlhealthineers
- Rapid point
- Rapidpoint
- Rapidpoint 500e
- Rapidpoint500e
- 500e