RAPIDPoint® 500e Blood Gas System Running A Sample Using the Ionized Calcium QuickTM Sampler
This video will show you the steps on how to run a sample using the RAPIDPoint® 500e Blood Gas System Ionized Calcium QuickTM Sampler.
View the following video before you use the ionized calcium quick sampler. Select the venous sample type button, select the ionized calcium parameter only, or by selecting the custom panel created for ionized calcium. Only mix the sample in the lithium heparin tube thoroughly. Open the sample tube within 30 seconds after mixing firmly, push the ionized calcium quick sampler onto the open tube. Insert the ionized calcium quick sampler lure into the sample port. Select the start button, wait for the sample to aspirate. The sample port will return to its original position after the sample has been aspirated. Grasping the ionized calcium quick sampler, not the tube. Firmly remove the sampler and the tube from the sample port. Select the continue button to initiate the sample analysis. Play the video again if you need help running a sample using the ionized calcium quick sampler.
@ 2021 Siemens Healthcare Diagnostics Inc. All rights reserved. RAPIDPoint and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc., or its affiliates. The system is temporarily busy. Please wait. All other trademarks are the property of their respective owners. Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in SIEMENS this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware pcoz available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Healthineers Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially Effective Date March 31, 2021 available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is HOOD05162003155009 not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. SIEMENS Copyright @ Siemens Healthcare GmbH 2021 The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Global Siemens Healthineers Headquarters Offenders will be liable for damages. Henkestr. 127 91052 Erlangen, Germany All names and data of patients, parameters and configuration dependent designations are fictional and examples only. Phone: +49 9131 84 0 siemens.comlhealthineers All rights, including rights created by patent grant or registration of a utility model or design, are reserved.
- Rapid point
- Rapid Comm
- blood gas
- complete
- automatic
- Calcium. Ionized