RAX Tube Tilt
This job aid will guide users through the steps for tilting the tube.
RAX: Tube Tilts for Cranial, Caudal and Oblique Views XPRF At the Remote-Control Console (RCC), Oblique Beam Angulation (1) for Cranial/Caudal views and RaxOrbit (2) for oblique C-arm views are performed by using the joystick and LED’s on the buttons above it. Typical starting position is in “Tube Tilt” Mode, used for Cranial/Caudal movement. The LED on the left most button will be Green. (1) (2) 1. With the Oblique Beam LED (1) selected (solid), pushing and holding the joystick to the left will angle the tube toward the feet, into a caudal position. Pushing and holding the joystick to the right will angle the tube toward the head, into a cranial position. 2. To move the tube for oblique C-arm views, push and hold the “C-Arm RaxOrbit” button on the right (2). The tube head will rotate in preparation for oblique imaging. Hold this button until the movement is complete, and the green LED light is solid over the button. NOTE: If the button is released early, the LED lights over both buttons will flash and rotation will not be possible. ,8 Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Job Aid | RAX: Tube Tilts Effective Date: 12/18/2020 | HOOD05162003156129 NOTE: Movements for oblique positions function best when the table is at its highest position. This allows faster movement of the detector around the table because of the decreased likelihood of moving through the collision zones of the floor and table. a. In this position, pushing and holding the joystick to the left will cause the tube to start moving into an RPO position. Angulation in this direction is limited by the tube and detector coming close to each other. b. Pushing and holding the joystick to the right will cause the tube to start moving into an LPO position. The tube will automatically stop when it reaches 90 de- grees. To go beyond this, release the joystick and re-engage. Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 2 of 3 Job Aid | RAX: Tube Tilts Effective Date: 12/18/2020 | HOOD05162003156129 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter co llectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written auth ority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 3 of 3
- Multitom RAX