RAX: Using RAX align

This job aid covers the steps to follow to utilize RAXalign

RAX: Using RAX Align XPRF RAX Align is automated tube-to-detector and detector-to-tube alignment. The tube and detector will be centered perpendicular to the one another. Tube/detector tracking will be available if they are both at 0 or 90 degree angles. There are three places to perform this action. 1. On the detector stand: Holding this button will “call” the tube into alignment with the position of the detector. 2. On the tube: Holding this button will “call” the detector into alignment with the position of the tube. 15.05.1958 Shoulder joint a.p. in a lying p .. B & 20 cm H ACSS & # 20 cm = Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/25/2021 | HOOOD05162003162790 Healthineers Job Aid | RAX: Using RAX Align Effective Date: 01/25/2021 | HOOD051652003162790 3. On the table kickplate: Tapping and holding the right foot kick will “call” the tube into align- ment with the position of the detector. EE - NOTE: If the action is not possible for any reason, such as movement into a collision zone, the components will not move. Collision zones can be walls, the floor, or the table. The error mes- sage “Collision risk between tube and tabletop” will display if the problem is the being in the way. Try moving the table higher or lower so that it is not in the path of the components. SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Page 2 of 3 Job Aid | RAX: Using RAX Align Effective Date: 01/25/2021 | HOOD051652003162790 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter co llectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written auth ority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Page 3 of 3

  • RAX