Respiratory Gating: Adjust Breath Wave Using Gain and Offset
Respiratory Gating: Adjust Breath Wave Using Gain and Offset step by step
Respiratory Gating: How to Ad- just the Breath Wave Using Gain and Offset [Anzai System] Computed Tomography By default, the mechanism is set to automatically adjust the breath wave for optimal results. If manual breath wave setup is chosen, automatic adjustment is switched off until the examination is ended. 1. Left-click on the Trigger sub-task card to select it. 10 20 30 40 60 70 80 90 100 7 P Original RESP . Average CT IIII uto Tasking Trigger 2. Left-click on the Curve Setup icon. The "Gain" and "Offset" sliders will be displayed. Curve setup Original RESP v Average CTI Auto Tasking Trigger 3. Move the "Gain" slider to modify the Respiration Rate (rpm) Min 14 Mar 15 Avg 14 curve amplitude. 4. Move the "Offset" slider to shift the entire curve along the y-axis until the desired value and the respective osition are reached. 5. Click the Close button to switch back Gain - 15 Offset - 39 Close to the normal display mode. Trigger 6. Allow three (3) cycles to pass in "normal display mode" to see the final "Gain" and "Offset" adjustments. SIEMENS siemens.com/healthineers Healthineers Job Aid | Respiratory Gating: How to Adjust the Breath Wave Using Gain and Offset [Anzai System] Effective Date: 12/6/2016 | Quality 1409 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright @ Siemens Healthcare GmbH ...... ........... Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 2 of 2