Respiratory Gating: Editing Syncs in the Trigger Card
Respiratory Gating: Editing Syncs in the Trigger Card step by step
Respiratory Gating: Editing Syncs in the Trigger Card Computed Tomography If the sync points on the Respiratory Gating breath wave are not ideal, they can be manually edited to help improve the outcome of the image data reconstruction. Respiratory Gating syncs can be moved, inserted, disabled, or deleted. 1. Respiratory Gating syncs can be MOVED if the sync is not in the desired location. This is useful when - as in the example below - a sync is near but not at the full inspiration peak of the breath wave. Left mouse click the sync and drag it to the desired location on the breath wave. The blue reconstruction bars will realign to coincide with the moved sync. () Min: 11 Max: 23 Avg: 12 Min: 11 Max: 23 Avg: 12 Min: 11 Max: 23 Avg: 12 6 6 6 2. Respiratory Gating syncs can be INSERTED when an inspiration or expiration sync is missing from a peak or valley of the breath wave, as in the example below. Right mouse click at the location where a sync is to be added, and select Insert Inspiration Sync or Insert Expiration Sync as applicable. Respiration rate (rpm) Min: 6 Max 23 Ava: 12 10 16 Respiration rate (rpm) Min: 6 Max: 23 Avg: 12 Insert Inspiration Sync Insert Expiration Sync Auto detect Syncs Adapt curve scaling 6 10 Zoom Fit 16 Zoom Out Respiration rate (rpm) Min: 11 Max: 23 Avg: 12 11 12 10 12 16 SIEMENS siemens.com/healthineers Healthineers Job Aid | Respiratory Gating: Editing Syncs in the Trigger Card Effective Date: 3/9/2017 | Quality HOOD05162002577809 3. Respiratory Gating syncs can be DISABLED when the breathing pattern between syncs is not as regular as the surrounding breath wave. This is useful when - as in the example below - the patient coughs during the scan but the rest of the breathing pattern is acceptable. Right mouse click at the location where a sync is to be disabled, and select Disable Sync. Respiration rate (rpm) Min: 11 Max: 23 Avg: 12 11 12 12 16 Respiration rate (rpm) Min: 11 Max: 23 Avg: 12 11 11 Delete Sync Disable Sync Adapt curve scaling Zoom Fit Zoom Out 10 12 16 Respiration rate (rpm) Min: 11 Max: 23 Avg: 12 11 12 2 6 10 12 14 16 4. Respiratory Gating syncs can be DELETED when more than one inspiration or expiration sync is placed at a peak or valley of the breath wave. Right mouse click at the location where a sync is to be deleted, and select Delete Sync. Respiration rate (rpm) Min: 11 Max: 23 Avg: 12 11 6 10 12 14 16 Respiration rate (rpm) Min: 6 Max: 23 Avg: 12 Insert Inspiration Sync Insert Expiration Sync Auto detect Syncs Adapt curve scaling 10 Zoom Fit 16 Zoom Out Respiration rate (rpm) Min: 11 Max: 23 Avg: 12 11 12 10 12 16 Siemens Healthineers Services Page 2 of 3 Job Aid | Respiratory Gating: Editing Syncs in the Trigger Card Effective Date: 3/9/2017 | Quality HOOD05162002577809 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright @ Siemens Healthcare GmbH ...... ........... Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 3 of 3
- Respiratory Gating: Editing Syncs in the Trigger Card