Respiratory Gating: Using Auto Detect and Zoom in the Trigger Card

Respiratory Gating: Using Auto Detect and Zoom in the Trigger Card step by step

Respiratory Gating: Using Auto Detect and Zoom in the Trigger Card Computed Tomography 1. If a Respiratory Gated breath wave has imported without syncs, use Auto Detect to correct.  On the Trigger card, right mouse Respiration rate (rpm) Min: 3 Max 12 Avg: 11 click and select Auto detect Syncs Insert Inspiration Sync Insert Expiration Sync Auto detect Syncs Adapt curve scaling 10 12 Zoom Fit Zoom Out 0 10 20 30 40 50 00 70 80 00 100 Est. Respiration rate > 12 Original RESP Average CT Routine Scar Recon Auto Tasking Trigger  Syncs will be automatically Respiration rate (rpm) Min: 12 Max: 23 Avg: 12 inserted at the peaks and 23 12 12 valleys of the breath wave to allow for reconstruction 10 12 0 10 20 30 40 50 60 70 80 00 10 Est. Respiration rate > 12 Original RESP Average CT Routine Scan Recon | Auto Taskina Trigger 2. To view more or less of the breath wave in the Trigger card, right mouse click and select Zoom Out or Zoom In. Respiration rate (rpm) Min: 12 Max 23 Avg: 12 Respiration rate (rpm) Min: 12 Max. 23 Avg: 12 Adapt curve scaling Zoom Fit 18 22 2 6 10 18 22 Zoom Out Zoom In Zoom 100% Est Respiration rate > 12 ] Original RESP Est Respiration rate > 12 ] Original RESP Average CT Average CT Routine Scan Recon Auto Tasking Trigger Routine Scan Recon | Auto Tasking Trigger SIEMENS siemens.com/healthineers Healthineers . Job Aid | Respiratory Gating: Using Auto Detect and Zoom in the Trigger Card Effective Date: 3/2/2017 | Quality HOOD05162002575436 3. To view the entire breath wave in the Trigger card, right mouse click and select Zoom Fit. Respiration rate (rpm) Mit: 12 Max 23 Avg: 12 Respiration rate (rpm) Mit: 12 Max 23 Avg: 12 Adapt curve scaling Zoom Fit Zoom Out Zoom In Zoom 100% Est Respiration rate > 12 ] Original RESP Est Respiration rate :12 Original RESP Average CT Average CT Routine Scan Recon |Auto Tasking Trigge Routine Scan Recon |Auto Tasking Trigger 4. To view the breath wave at the default size in the Trigger card, right mouse click and select Zoom 100%. Respiration rate (rpm) Min 12 Max 23 Avg: 12 Respiration rate (rpm) Min: 12 Max 23 Avg: 12 Adapt curve scaling Zoom In Zoom 100% 56 10 12 114 Est Respiration rate > 12 Original RESP Est Respiration rate > 12 Original RESP Average CT Average CT Routine Scan Recon Auto Tasking Trigger Routine Scan Recon | Auto Tasking Trigger Siemens Healthineers Services Page 2 of 3 Job Aid | Respiratory Gating: Using Auto Detect and Zoom in the Trigger Card Effective Date: 3/2/2017 | Quality HOOD05162002575436 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright @ Siemens Healthcare GmbH ...... ........... Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 3 of 3

  • Respiratory Gating: Using Auto Detect and Zoom in the Trigger Card