Roadmap Additional Functions (VC21-VD11) Job Aid
This job aid describes the additional functions that can be performed with roadmaps.
Roadmap Additional Functions (VC21 – VD11) Job Aid Advanced Therapies – Artis Software VC21 to VD11. **There is an additional job aid availa- ble on PEPconnect to determine SW version of the system. When using Roadmap, the below listed functions may be applied, as needed, to aid in the visuali- zation of catheters, wires, or devices, the deployment of coils or glue, and allows user to re-use previously acquired roadmaps. Vessel/Catheter Contrast Percentage (VC/CC%) • This function allows user to adjust the catheter (wire, device, etc.) and vessel contrast percentages independently. The percentages are displayed in the lower right corner of LIVE image. • Activate from the touchscreen icon or from the PostProc taskcard main menus in the control room. PostProc > Image main menu > Change Vessel / Catheter Contrast Settings Exam Image Quant 4D V NC % Contrast Previous show Mask Progress RM Neuro Reset Roadmap 15 p/s 7.5 f/s RDMP DSA RDMP ×2 Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 08/14/2020 | HOOD05162003116155 Healthineers Job Aid | Additional Roadmap Functions Effective Date: 08/14/2020 | HOOD05162003116155 • Contrast can be adjusted with the touch screen joystick using last image hold or from the control room main menus, if needed. The percentage cannot be adjusted during live fluoro. • To adjust the vessel contrast, move the joystick up and down. VC% can be adjusted from 0 - 200%. • To adjust the wire/catheter contrast, move the joystick left to right. CC% can be adjusted from 50 - 200%. Vessel / Catheter Contrast ? X Vessel Contrast [%] 50 Catheter Contrast [%] 50 Apply OK Cancel • Additionally, VC/CC% can be changed to Anatomical Background % from the main menus in control room. Anatomical Background % and VC/CC% cannot be accessed simultaneously from the touchscreen. Adaptation from the control room needs to be performed each time the other function is needed Acquisition > Anatomical Background or Acquisition > Vessel/Catheter Con- trast Settings Exam Image Quant 4D % Anatom. Do Backgr. Previous Show Mask Progress RM Neuro Reset Roadmap 15 p/s 7.5 f/s RDMP DSA RDMP x2 Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 08/14/2020 | HOOD05162003116155 Healthineers Page 2 of 6 Job Aid | Additional Roadmap Functions Effective Date: 08/14/2020 | HOOD05162003116155 Zoom x2 / Pan • The Roadmap image can be zoomed x2 and panned to the area of interest. • Select the Zoom x2 icon from the touchscreen or the control room. • Use the TSC joystick to pan the image. On biplane systems, both planes will be zoomed. Settings Exam Image Quant 4D Anatom. %Backgr. Previous Mask Show 5 Progress Review RM Neuro Reset Roadmap Pan Exit 15 p/s 7.5 f/s RDMP DSA RDMP x2 Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 08/14/2020 | HOOD05162003116155 Healthineers Page 3 of 6 Job Aid | Additional Roadmap Functions Effective Date: 08/14/2020 | HOOD05162003116155 Show Progress • When Show Progress is activated, during a pause in radiation release, the current roadmap mask is replaced by the LIH. This allows the user to improve the visualization of the progression of the injection of any radiopaque material, like Onyx, or coil placement. • Show Progress subtracts out previously displayed coils or radiopaque material from the original roadmap. • Select the Show Progress icon from the touchscreen (it will NOT change to white to demonstrate that it is active; user will only receive message on LIVE monitor) or from the control room. • A message will display: Show Progress: a new mask will be acquired. • Step on fluoro for 2 seconds. Initial image will be live fluoro and STAY ON the fluoro pedal until the image subtracts. Settings Exam Image Quant 4D o/ Anatom. 7º Backgr. Soy Previous 5 progress Roadmap Mask RM Neuro Reset Roadmap G 15 p/s 7.5 f/s A Close Help RDMP DSA RDMP x2 .................................................................. Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 08/14/2020 | HOOD05162003116155 Healthineers Page 4 of 6 Job Aid | Additional Roadmap Functions Effective Date: 08/14/2020 | HOOD05162003116155 Previous Roadmap Mask (Not for use with DSA Roadmap) • This function allows the user to return to a previously created Roadmap. On a single place system, the user can toggle between two roadmap positions. On a biplane system, the user can return to the last roadmap position for either A plane, B plane, or both planes. • Select Previous Mask icon from touchscreen or control room. Message will appear asking user to Activate stand movement or Deflect joystick. Settings Exam Image Quant 4D o/ Anatom. Backgr. ‹ Previous Show Progress Roadmap ?x Mask RM Neuro Reset Roadmap G 15 p/s 7.5 f/s A Close Help ........................................................ RDMP DSA RDMP x2 Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 08/14/2020 | HOOD05162003116155 Healthineers Page 5 of 6 Job Aid | Additional Roadmap Functions Effective Date: 08/14/2020 | HOOD05162003116155 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter co llectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cauti ons. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written auth ority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 08/14/2020 | HOOD05162003116155 Healthineers Page 6 of 6
- VC21
- VD11
- roadmap