ACUSON S2000 ABVS Quick Card
The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages.
All names and data of patients, parameters and configuration dependent designations are fictional and examples only.
All rights, including rights created by patent grant or registration of a utility model or design, are reserved.
Please note that the learning material is for training purposes only!
For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training.
The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions.
Note: Some functions shown in this material are optional and might not be part of your system. The information in this material contains general technical descriptions of specifications and options as well as standard and optional features that do not always have to be present in individual cases.
Certain products, product related claims or functionalities described in the material (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information.
Copyright © Siemens Healthcare GmbH, 2020
All names and data of patients, parameters and configuration dependent designations are fictional and examples only.
All rights, including rights created by patent grant or registration of a utility model or design, are reserved.
Please note that the learning material is for training purposes only!
For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training.
The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions.
Note: Some functions shown in this material are optional and might not be part of your system. The information in this material contains general technical descriptions of specifications and options as well as standard and optional features that do not always have to be present in individual cases.
Certain products, product related claims or functionalities described in the material (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information.
ACUSON S2000 Automated Breast ACUSON ABVSume scanner Volume Scanner (ABVS) Quick Card Step-by-Step HELX BLUTION siemens-healthineers.com/abvs Siemens Healthineers offers a wide range of breast imaging products – the ACUSON S2000 ABVS, the ACUSON S Family, ACUSON X Series and ACUSON NX Series. Step 1 Step 6 • Attach single use • Verify the correct view membrane • Select the cup size preset and ensure the A A A depth is correct • Step 2 Ensure adequate contact to provide consistent • Place patient in the supine coverage position • Place supportive cushion Step 7 behind the back so that • Press arrow to initiate patient’s nipple is pointing image acquisition toward the ceiling • The complete scan will • Position arm to evenly go in the direction of distribute breast tissue the arrow usually from inferior to superior Step 3 • Evenly apply lotion to Step 8 14LSBV Eread the breast using spatula 2D-100% GEN Place the nipple marker Change 11.00 MHZ DAB/DATO • Ctis or tongue depressor MAPASTI over the nipple • Verify view type is Step 4 correct and modify if necessary • Place the pod over • breast and center Press “Accept” according to the desired view Step 9 • Step 5 When all views have Patient Review been completed for both • Lock the transducer breasts, simply select End Apply a small amount of “End Exam” key on the Exam Report • pressure to stabilize the - control panel. breast SIEMENS Healthineers AP Place the pod over the central portion of the breast so that it is parallel with the chest wall. SIEMENS Include: • Central portion of the breast, superior and inferior tissue borders Symmetrical round breast Lateral Place the lateral edge of the pod along the mid axillary line. Scoop and flatten the breast tissue so that it is parallel to the chest wall. Include: • Superior and inferior borders of lateral breast to include the axillary tail • Edge of tapering lateral breast tissue Medial Place the medial edge of the pod along the opposite sternal edge. Gently lower the center SIEMENS of the pod onto the breast and slide laterally. Include: • Superior and inferior borders of the medial breast to include the inframammary fold • Sternum, rib and intercostal muscle medially Superior Place the superior edge of the pod just below the clavicle. Roll pod toward the nipple. Include: • Superior aspect of the breast from the clavicle to the nipple Inferior Place the inferior edge of the pod 2 inches SIEMENS below the breast border. Slide the pod toward the nipple until adequate contact is visualized. Include: • Inferior aspect of the breast from the inframammary to the nipple ACUSON S2000 ABVS, ACUSON S Family, ACUSON X Family,and ACUSON NX series are trademarks of Siemens Medical Solutions USA, Inc. Siemens Healthineers Headquarters Legal Manufacturer Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc. Henkestr. 127 Ultrasound 91052 Erlangen, Germany 22010 S.E. 51st Street Phone: +49 9131 84-0 Issaquah, WA 98029, USA siemens-healthineers.com Phone: 1-888-826-9702 siemens-healthineers.com/ultrasound Published by Siemens Medical Solutions USA, Inc. · 8846 0220 online · ©Siemens Medical Solutions USA, Inc., 2020
- abvs
- s2000
- breast
- 3D
- volume