SENSIS Vibe VD12 Keyboard Job Aid
This Job Aid provides information about the syngo Keyboard for Sensis Vibe with the software version VD12 or higher.
SIEMENS Healthineers syngo Keyboard Job Aid Sensis Vibe VD12 Template Effective Date: 05/27/2019 | HOOD05162003010284 1 Job Aid Effective Date: 08/27/2020 | HOOD05162003118937 Unrestricted © Siemens Healthineers, 2020 Table of Contents SIEMENS Healthineers syngo Keyboard 3 Symbolic/Numeric keypad 4 Function keys 8 SIEMENS Note: The product and/or features here mentioned may not be commercially available in all countries. Due to regulatory reasons their future availability cannot be guaranteed. Please contact your local Siemens Healthineers organization for further details. 2 Effective Date: 08/27/2020 HOOD05162003118937 Unrestricted © Siemens Healthineers, 2020 Quick access to frequently used functions SIEMENS Healthineers syngo keyboards will be delivered with the system. Num Lock With these keyboards there are changes to the Symbolic/Numeric keypad 8 9 + area. Please regard that certain symbolic functions are only active when the 4 5 6 appropriate application (Hemodynamics, Electrophysiology) is active or O during Post Processing. 2 3 Enter - Depending on your system User Interface language, the PC REC -12 characters associated with Num Lock may differ. O 3 Effective Date: 08/27/2020 HOOD05162003118937 Unrestricted © Siemens Healthineers, 2020 Symbolic/Numeric keypad SIEMENS Healthineers Key Function Num Num Lock Lock Toggles between the input of the numeric keypad and symbol keypad. When Num Lock is active the symbolic keys are inactive and vice versa Decrease sweep speed mm/s With each button push, selects the next lower available display sweep speed (If at the lowest speed no further interaction will be applied) Increase sweep speed mm/s With each button push, selects the next higher available display sweep speed (If at the highest speed no further interaction will be applied) Stimulation on/off (Electrophysiology application only) | IL Deactivates all stimulation channels (if more than one stimulation channel is configured) OR Activates/deactivates stimulation channel 1 (if only one stimulation channel is configured) 4 Effective Date: 08/27/2020 HOOD05162003118937 Unrestricted © Siemens Healthineers, 2020 Symbolic/Numeric keypad SIEMENS Healthineers Key Function 7 Oxygen saturation (Hemodynamics application only) Quick access to enter sampling site 8 Print waveforms Prints the waveforms currently displayed on the Review task card to your configured default standard printer. (Split screen: the whole screen is printed | Active window: only the currently active window is printed in full screen size) 9 Split / un-split screen Used for comparing two waveform recordings Toggles the screen viewing area 4 Balance Pressure Opens the Balance Pressure Transducers dialog box 5 Effective Date: 08/27/2020 HOOD05162003118937 Unrestricted © Siemens Healthineers, 2020 Symbolic/Numeric keypad SIEMENS Healthineers Key Function 5 Mark Event Opens the Select Comment dialog for adding or selecting a pre-configured comment and is added to the CaseLog as an event 6 Duplicate Waveform Area The real-time monitor in the examination room displays the waveform area of the dialog monitor Retro record on/off Starts the recording of the current waveform sampling plus the last 30 seconds of the waveform sampling (The default REC buffer is 30 seconds, but can be changed through the Retro Record Properties) 2 12 lead ECG snapshot Creates a snapshot recording with focus on the 12 lead ECG view (Depending on configuration, the recording is immediately displayed on the Review task card and/or printed out from your default printer) 6 Effective Date: 08/27/2020 HOOD05162003118937 Unrestricted © Siemens Healthineers, 2020 Symbolic/Numeric keypad SIEMENS Healthineers Key Function Hemodynamic Worksheet (Hemodynamic application only) 3 Opens the overview of hemodynamic measurement results and other derived data for the current examination, sorted by condition Patient Registration 0 Opens the Patient Registration dialog Patient Browser Opens the Patient Browser Start Pressure calculation (Hemodynamic application only) Starts a pressure calculation from the currently acquired real-time signals and opens the Calculation Event Properties dialog Enter Snapshot Creates a short waveform recording of currently acquired signals and displays on the Review task card; and creates an event in the CaseLog which can be specifically labeled 7 Effective Date: 08/27/2020 HOOD05162003118937 Unrestricted © Siemens Healthineers, 2020 Function keys SIEMENS Healthineers Shortcuts to frequently used Event Comments F1 F2 F3 F4 F5 F6 F7 F8 F9 10 F11 12 The function keys on the keyboard provide shortcuts to specific functions and event comments. Some functions are fixed to a specific function key. Event comments are configurable to which function key they are associated with. The function keys are located along the top portion of the keyboard. 8 Effective Date: 08/27/2020 HOOD05162003118937 Unrestricted © Siemens Healthineers, 2020 Function keys SIEMENS Healthineers Key Function Online Help F1 Opens the Online Help function This is a fixed configuration No function at this time F2 No function at this time F3 No function at this time F4 9 Effective Date: 08/27/2020 HOOD05162003118937 Unrestricted © Siemens Healthineers, 2020 Function keys SIEMENS Healthineers Key Function No function at this time F5 No function at this time F6 Mark Event Comment F7 Comments configured in the Event Configuration dialog Mark tab can be assigned to F7 – F12 function keys as shortcuts for entering commonly used comments (e.g. balloon dilatation start, ablation start) Mark Event Comment F8 Comments configured in the Event Configuration dialog Mark tab can be assigned to F7 – F12 function keys as shortcuts for entering commonly used comments (e.g. balloon dilatation start, ablation start) 10 Effective Date: 08/27/2020 HOOD05162003118937 Unrestricted © Siemens Healthineers, 2020 Function keys SIEMENS Healthineers Key Function No function at this time F9 No function at this time F10 Mark Event Comment F11 Comments configured in the Event Configuration dialog Mark tab can be assigned to F7 – F12 function keys as shortcuts for entering commonly used comments (e.g. balloon dilatation start, ablation start) Mark Event Comment F12 Comments configured in the Event Configuration dialog Mark tab can be assigned to F7 – F12 function keys as shortcuts for entering commonly used comments (e.g. balloon dilatation start, ablation start) 11 Effective Date: 08/27/2020 HOOD05162003118937 Unrestricted © Siemens Healthineers, 2020 SIEMENS Healthineers Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH Global Siemens Healthineers Headquarters Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84 0 siemens.com/healthineers 12 Effective Date: 08/27/2020 HOOD05162003118937 Unrestricted © Siemens Healthineers, 2020
- Sensis Vibe