Simultaneous Multi-Slice (SMS)

Simultaneous Multi-Slice (SMS)

SMS is an MRI acceleration technique based on simultaneous multi Slice acquisition. As the name implies, simultaneous multi slice acquires multiple slices at the same time instead of 1 after the other. For this it uses a multiband excitation pulse and spatially encodes the signals of the slices simultaneously. This means, for example, that an SMS Factor 3 excites three slices simultaneously with three excitation frequencies. During the acquisition, Blip type arenia is used to shift the different slices in the field of view. The slice greppi uses coil sensitivity information in slice direction to separate the different slices followed by the in plane grappa reconstruction. SMS accelerates imaging by a factor equal to the number of slices that are required simultaneously. The maximum acceleration factor is limited by the coil configuration and the number of elements in slice direction. SMS can also be combined with graph acceleration compared to the conventional parallel imaging speed up, however, SMS circumvents the signal to noise ratio loss associated with data undersampling. Acceleration is the main benefit of SMS. Depending on the clinical application and body region, SMS offers additional benefits ranging from higher volume coverage to higher spatial resolution, increased temporal resolution and shorter breath hold times.

Gz Gz @ Siemens Healthcare GmbH, 2019 Gz SMS Fully encoded image Please note that the learning material is for training purposes only! SMS image For the proper use of the software or hardware, please always use the Operator Manual or SMS Gz Gz Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily Breast reflect the latest version of the software and hardware available at the time of the training. Knee The Operator Manual shall be used as your main reference, in particular for relevant safety Neuro Hand/Wrist Liver information like warnings and cautions. Breast Note: Some functions shown in this material are optional and might not be part of your system. The SMS information in this material contains general technical descriptions of specifications and options as Neuro well as standard and optional features that do not always have to be present in individual cases. Neuro Certain products, product related claims or functionalities described in the material (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not Neck guaranteed. Please contact your local Siemens Healthineers sales representative for the most current Foot/AnkIe Neck Foot/AnkIe information. Shoulder Pelvis Hip The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. No SMS SMS 2 All rights, including rights created by patent grant or registration of a utility model or design, are TA 02:03 min 01:01 min reserved. TR = 2370 ms [minimized] TR = 4730 ms