SOMATOM go. platform Endoscopic View Job Aid (VA20)
This Job Aid guides you through the Endoscopic View workflow of CT View&GO for the SOMATOM go. VA20 software version in 8 easy steps.
Endoscopic View Job Aid SOMATOM go. VA20 CT View&GO In 8 easy steps, this document guides you through the Endoscopic View workflow of CT View&GO for the SOMATOM go. VA20 software version. Please note: The following workflow describes one possible way out of various to perform it. Step 1: Load CT Colon patient data into CT View&GO (1 and 2). SIEMENS. Healthineers adminUser v ? @ = = Scan 4 = Recon 1 Patient Browser X Local Data 2 Search by Name, ID, Date, Description and Modality (Ctrl+F) More Filters Open Open with DICOM Import Export Correct Delete Manage Recon O/R Raw Data Results (41 results, 3:05:57 PM) Series Open with View&GO Patient Name Date of Birth P Modality Study Date and Time Study Description Delete Protect. + Series Number Series Description Modality # Instances + CT Colon, S64_Colon_Polyp_in_Prone_Tagging 6/8/1950 1 CT 11/20/2006 9:51:2 Abdomen^Abdom. Colo_supine 0.75 B20f CT 89 Anonymous 3/30/2018 3/30/2018 11:41:5 .. 01_Coronary CTAL. Colo_prone 0.75 B20f CT 94 Brumann, Paul Johann 3/5/1927 104104/20 CT 8/4/2009 4:56:59 PM Cardiac^DS_Herz. CaScore_DHM_00002 1/1/1938 a9471b6ef0 CT 5/16/2008 10:53:4 Cardiac^Herz_ME ... CaScore_DHM_00013 1/1/1945 aae5226567 CT 3/13/2008 2:57:25. Cardiac^Herz_ME. Chavez, Randal 1/15/1970 75472460-97 CT, SR 5/4/2018 4:20:42 PM Whole Body Bone( ... Cohen, Alisa 12/29/1971 d675d4a4-b7 CT, SR 4/27/2018 3:42:16 Thorax(Adult) Cross, Federico 6/11/1942 686d9670-3e CT, SR 5/4/2018 3:19:44 PM Thorax(Adult) FLASH CORONARY, 1 8/30/1951 1111 CT 9/25/2009 2:45:20 Cardiac^01_Flash ... Mcconnell, Tanya 9/17/1922 3c53ce28-57 CT, SEG, 5/1/2018 11:49:09 Thorax(Adult) MEP_China_03_2017_00001 LONNIE 1/1/1956 71bb21a648 CT, SR 2/23/2017 9:18:22 01_HeadRoutine( ... MEP_China_03_2017_00003_Scott 1/1/1953 837c3b4aa0 CT, SR 2/23/2017 10:29:5. 02_GZ_Abdomen( ... MEP_China_03_2017_00003_Scott 1/1/1953 837c3b4aa0 CT, SR 2/23/2017 10:27:5 02_GZ_Thorax(Ad. MEP_China_03_2017_00003_Scott 1/1/1953 837c3b4aa0 CT, SR 2/23/2017 10:24:0 02_GZ_Abdomen( ... MEP_China_03_2017_00003_Scott 1/1/1953 837c3b4aa0 CT, SR 2/23/2017 10:21:4 02_GZ_Thorax(Ad Instances MEP_China_03_2017_00003_Scott 1/1/1985 837c3b4aa0 CT, SR 2/23/2017 9:59:49 01_CN_Abdomen(. MEP_China_03_2017_00003_Scott 1/1/1985 837c3b4aa0 CT, SR 2/23/2017 9:57:59 01_CN_Thorax(Ad. MEP_China_03_2017_00003_Scott 1/1/1956 837c3b4aa0 CT, SR 2/23/2017 9:53:56. 02_GZ_Abdomen( ... MEP_China_03_2017_00003_Scott 1/1/1956 837c3b4aa0 CT, SR 2/23/2017 9:50:41 02_GZ_Thorax(Ad. Osteo Spiral 1 4/12/1951 Osteo Spiral 1 CT 10/14/2015 12:36 CT Osteodensitom ... Osteo Spiral 2 2/18/1956 Osteo Spiral 2 CT 10/12/2015 9:51:5 CT Osteodensitom ... Osteo_Anke_LWS 4/12/1951 Anke_LWS CT 10/14/2015 12:36 Abdomen^Osteod. 4 450 Osteo_SPI_01_L2L3L4L5 4/12/1951 Osteo_SPI 0. CT 10/14/2015 12:36 Abdomen^Osteod .. Osteo_SPI_01_L3L4L5 4/12/1951 Osteo_SPI_0 CT 10/14/2015 12:36 Abdomen^Osteod ... OsteoSpine_SpiralTilt 1/28/1955 123 CT 1/28/2015 12:28:5. Abdomen^Abdom ... OsteoU_Sequ_PhantDetect_Failed 1/1/1940 OsteoU_Seq. CT 4/10/2014 10:38:4 Spezial^07_Osteo OsteoU_Sequ_PhantDetect_Failed OsteoU_Seq CT 6/27/2013 2:51:13. The selected data opened 3:06 PM SIEMENS siemens.com/healthineers Healthineers . Endoscopic View Job Aid | SOMATOM go. VA20 CT View&GO Effective Date: 06/29/2018 | HOOD05162002906039 Step 2: Select the dataset through which you would like to fly ( 1 ). Health needs adminUser RE Scan 4 = Recon 1 CT Colon, $64_Colon_Polyp_in_Prone_Ta ... X 6/8/1950 M. CT View&GO Series X +:+ Viewing 4 IMA1 SP F 278.0 5 IMA 1 SP F265.5 Add Study THE Stack 4x4 roos Up MPR VRT Current _ CT, 11/20/2006 "Abdomen^ AbdomenRoutine (Adult) MPR MIP MPR Stack 2x2 Vessel Compare Please drog data from Series Navigator. o supine 0.75 Colo prone 0.75 Printing Distribution ST_SOMS SPI SL 0.8 ref.mas 180 LO.8 CT-SOMS.SP 120 ref mAS 40 V Nativ Nativ Favorite Tools Distance ROI Circle Parallel Snapshot Line Ranges Exage Fort Show in Remove Endiese .. Coronary Heart Please drag data from Series Navigator. Please drag data from Series Nijvigator Please drag data from Series Navigator. Solid Lung CAD Osteo Reset Lesion Series Windowing T Windowing Vascular * Ranges ROI HU Edin Result + 3:07 PM Step 3: Select the Endoscopic View tool from the Tool Gallery ( 1 ) or from the Favorite Tools. Healthineers adminUser E Scan 4 = Recon 1 CT Colon, 564_Colon_Polyp_in_Prone_Ta ... X 6/8/1950 M. CT View&GO Tool Gallery × Viewing SP F278.0 5 IMA1 Marker Arrow Text SP F265.5 3d Study Distor Stack 3x2 Stack 4x4 Follow Up MPR VRT Ranges 2TP MPR MIP Adult) P MPR Stack 22 v Ranges * Image Visualization Fillo FilloAca amphies Hide Lines Cylon Loh Printing Windowing Distribution ST_SOM5 SPI ref.mas 180 LO.8 CT SOMS. SP SLO.8 Windowing TermAS 40 V Nativ Nativ 3D Editing Favorite Tools x X Region Anatomy Punch Clip Box Clip Plane Remove Growing Visualizer Table Distance ROI Circle Parallel Snapshot Line Print & Export Ranges 7 x 1/x Export Show in Remove Snapshot Print Export Image 30 Bones Image Image Coronary Meat Postpr Please drag data from Series Naviga Please drag data from Series Najvigator Endosco .. Osteo Define View Solid Lung CAD Osteo Lesion Reset Windowing Activate Endoscopic View Mode Series T 1 Windowing Vascular * Ranges D wieder ROI HU + 3:09 PM Siemens Healthineers Services Page 2 of 6 Endoscopic View Job Aid | SOMATOM go. VA20 CT View&GO Effective Date: 06/29/2018 | HOOD05162002906039 Step 4: The layout changes to MPR VRT ( 1 ). Healthineers> adminUser f ) = Scan 4 = Recon 1 O _CT Colon, S64_Colon_Polyp_in_Prone_Ta ... 6/8/1950 M. CT View&GO Series Viewing SIMAn.a. FRM n.a. SP P157.0 Add Stud Stack 3x2 Stack 4x4 Follow Up 1 Current CT, 11/20/2006 MPR MIP Abdomen^AbdomenRoutine (Adult) COMPR Stack 22 Ves Colo_supine 0.75 Colo prone 0.75 Printing F Distribution MPR THICK KV 120 L0.5 MPR THICK KV 120 SL 0.5 ref.mas 40 350 ref.MAS 40 350 Favorite Tools A Distance ROI Circle 5 IMAn.a. FRM n.a. PL50 SPF501.8 Line Export Table R Solid Lesion Series Windowing * T Diamete MPR THICK F SL 0.5 SSD ROI HU ref.MAS 40 350 KV 120 tef mAS 40 350 TheLHE 40 40 RE L Natio 3:10 PM Step 5: After clicking Set Endoscope ( 1 ) at the bottom of the segment, define the camera posi- tion by clicking into the desired hollow organ ( 2 ), in our example the colon. Healthingers adminUser E Scan 4 = Recon 1 O CT Colon, $64_Colon_Polyp_in_Prone_Ta ... X * 6/8/1950 M CT View&GO Series Viewing 5 IMA -804 SP F667.5 5 IMAn.a. FRM n.a. SPP1914 Add Stud Stack 3x2 Stack 4x4 Fo Follow Up Current - 8 CT, 11/20/2006 MPR MIP Abdomen^AbdomenRoutine (Adult) IP MPR Stack 22 Vessel R 2 Colo supine 0.75 10cm Printing F A Distribution MPR THICK SL 0.5 MPR THICK KV 120 SL 0.5 ref.MAS 40 350 40 ref.mAs 40 350 40 V II 1 Set Endoscope Favorite Tools Distance ROI Circle 5 IMAn.a. FRM n.a. Parallel SP R2.4 SPF422 Line Ranges 17x Export Image Show in 30 View Define Vessels Tree ARH Solid Lung CAD Osteo Lesion Series T Windowing Vascular Diameter O MPR THICK SL 0.5 LOI HU ref.MAS 40 350 termAB 3 Nativ 3:21 PM In order to optimize the visualization, perform windowing in the SSD segment by using the middle mouse button / wheel ( 3 ). Siemens Healthineers Services Page 3 of 6 Endoscopic View Job Aid | SOMATOM go. VA20 CT View&GO Effective Date: 06/29/2018 | HOOD05162002906039 Step 6: Start flying through the SSD segment by pressing and holding the right mouse button while moving the mouse forwards and backwards ( 1 ). Click the left mouse button to perform stepwise navigation in the segment ( 2 ). Healthineers adminUser 1 1 E Scan 4 = Recon 1 O - 6/8/19501254_Colon_Polyp_in_Prone_Ta ... CT View&GO Series Viewing 5 IMA ~678 SP F605.0 SP P174.6 bution Stack 3x2 Stack 4x4 Follow Up Current 61. 11/20/2006 MPR MIP MPR S Stack 22 Vessel * Abdomen^AbdomenRoutine (Adult) R 10cm Colo prone 0.75 Printing F A Distribution MPR THICK SL 0.5 MPR THICK ref.MAS 4 350 kV 120 40 ref.mAs 40 Nathe Favorite Tools O. Distance ROI Circle 5 IMAn.a. FRM n.a SP L2.4 SPP479 9 1 Export Image Show in Remove Table Define View Vessels Tree 2 Solid Lesion Lung CAD Osteo Series Windowing WAAAAAAAMAN XT Windowing Vascular Diameter WHO MPR THICK KV 120 L0.5 ROI HU dit Resul ref.mas 40 350 tef mas 40 350 40 AE Nativ 3:48 PM Healthingers adminUser ? = = Scan 4 = Recon 1 O CT Colon, S64_Colon_Polyp_in_Prone_Ta ... X * 6/8/1950 M . CT View&GO AF Series X Viewing SIMA-69 SP F611.9 SIMAn.a. FRM n.a. DiSI Stack 3x2 Stack 4x4 Follow Up MPR Current - 8 CT, 11/20/2006 Abdomen^AbdomenRoutine (Adult) MPR MIP MPR Stack Vessel Compare R 10cm -B2Of 141 0.75 Colo prone 0.75 Printing F LAT Distribution MPR THICK SL 0.5 MPR THICK SL 0.5 ref.mAS 40 350 KV 120 350 40 ref.mAs 40 Natty Favorite Tools Distance ROI Circle Snapshot SIMAn.a. FRM n.a SP L13.0 SPF573.0 Line 1 image Remove Bones Coronary willig PHL Legion Osteo Series * MPR THICK SL 0.5 SSD ROL HU KV 120 ref.mAs 40 350 40 ref mAs 40 + 7 Natio 3:49 PM Siemens Healthineers Services Page 4 of 6 Endoscopic View Job Aid | SOMATOM go. VA20 CT View&GO Effective Date: 06/29/2018 | HOOD05162002906039 Step 7: Once you identify a finding, you can create Snapshots ( 1 ) for documentation purposes. They get documented in the Results section ( 2 ) of the Series Panel. Healthineers adminUser E Scan 4 = Recon 1 O _CT Colon, S64_Colon_Polyp_in_Prone_Ta ... X 6/8/1950 M. CT View&GO Series x Viewing 5 IMA ~720 SPF825. 5 IMAn.a. FRM n. SP P201.9 Stack 3x2 Stack 4x4 Follow Up Current CT, 11/20/2006 MPR MIP MPR .. Stack Abdomen^AbdomenRoutine (Adult) Stack 22 Vessel R Colo supine, 0.7 10cm Colo prone 0.75 Printing F Results MPR THICK 2 Distribution MER THICK SL 0.5 ref.MAS 40 W 350 KV 120 40 ref.mÁs 40 Favorite Tools 1 View&GO [1004) Thece ROI Circle Sni Create Snapshots [S] SPP567.5 X /x Export Image Show in Remove Pisonave Table View Coronary Vessels Tree PLH Lesion LUSO CAD O 10cm * Vindowins Vascular T amete MPR THICK SL 0.5 SSD KV 120 ROI HU Edit Fiesme termas 40 350 40 ref mAS 40 Nativ 3:52 PM Please note: For documentation purposes, you can create Snapshots at any time while perform- ing the relevant workflow steps. Step 8: You can perform additional measurements ( 2 ) in the other MPR segments by using the corresponding Favorite Tools ( 1 ) or tools from the Tool Gallery. Healthineers adminUser v ? ¿ = 1 = Scan 4 = Recon 1 O _CT Colon, S64_Colon_Polyp_in_Prone_Ta ... X 6/8/1950 M. CT View&GO Series Viewing Stack 3x2 Stack 4x4 Follow Up IMA n.a. FRM.n.a. SP L17.0 Current CT, 11/20/2006 MPR MIP Abdomen^AbdomenRoutine (Adult) Compare Stack 22 Vessel Colo_supine 0.75 B201 151 Printing Results Distribution Favorite Tools X View&GO [ 1004 Distance Ol Circle Line Rangkey Snapshot Export Image Show in 5cm Coronary probabile A Solid Lesion Lung CAD Osteo Series * T Diameter SL 0.5 Windowing Vascular Ranges 350 ROI HU + 3:54 PM Siemens Healthineers Services Page 5 of 6 Endoscopic View Job Aid | SOMATOM go. VA20 CT View&GO Effective Date: 06/29/2018 | HOOD05162002906039 Disclaimer Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Func- tionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales repre- sentative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH, 2018 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 6 of 6
- somatom go.
- somatom go
- somatom
- somotom
- somatom go. up
- somatom go.now
- somatom go. top
- somatom go. all