SOMATOM go.Sim & SOMATOM go.Open Pro Patient Marking Job Aid
This job aid guides you through the workflow for patient marking with DirectLaser for SOMATOM go.Sim and SOMATOM go.Open Pro.
Patient Marking Job Aid SOMATOM go.Sim SOMATOM go.Open Pro In 7 easy steps, this document guides you through the workflow for patient marking with DirectLaser for SOMATOM go.Sim and SOMATOM go.Open Pro. Please Note: This Job Aid reflects software version VA30. Step 1: Once the images are reconstructed and loaded to CT View&GO, select the data (1) and click Sim&GO at the toolbar area (2) to load them into the workflow. Healthingers syadmin = Scan 25 = Recon 2 Doe, Jane 3/18 /1951 (69) 12322344 CT View&GO CT View&GO Senes CT View&GO Doe, Jane SOMATOM go. Open Pro Doe, Jane 12322344 12322344 SOMATOM go open Pro syngo CT VA30A Stack 3x2 Stack 4x4 Follow Up MPR VRT MPR MIP MPR 3/18/1951, 69Y syngo CT VA30A Add Study Archive 21P Compare CURRENT HFS 3/18/1951, 69Y CURRENT 3/18/2020 3/18/2020 Head for dose calculation 1.50 Qr40 A2 [2] Head for contouring 1.50 Qr40 A2 [4] Current 8:46:52.35 AM 8:47:22.88 AM CT. 3/18/2020 SPI 200 DEMEP 300 2 IMA 166 4 IMA 169 RTP Head DE [factory](Adult) Favorite Tools SP F759.0 SP F754.5 R R Please dreg data from Series Navigator Ocm calculation 1 KV 120 KV 80/Sn140 Eff.mAs 345 1 F Eff.MAs 596 0.5 Series GT 0.0 GT 0.0 SL 1.5/64x0.6/p0.55 400 500 0/-12.23 200 SL 1.5/64x0.6/p0.35 500 0/-12.23 Qr401A2b .. :0268E:1Ah AS1 atA 40 Qr40.12b ME_AOkey, Filter Sn 1 Printing Favorite Tools 3D Distance ROI Circle O Paralel Snapshot Export Une Ranges Image Show in 30 Please arag data from Series Navigator. Please drag data from Serias Navigator. Please drag data from Series Navigator. 2 MO EN 3:55 AM Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 08/22/2017 | HOOD05162002647849 Healthineers Job Aid Effective Date: 07/31/2020 | HOOD05162003102312 Job Aid | Patient Marking Effective Date: 07/31/2020 | HOOD05162003102312 Step 2: After the data are loaded to Sim&GO, create the isocenter by moving the crosshair to the region of interest (1, 2, 3) and click Set POI (4). Healthingers syadmin ? M & # = Scan 25 = Recon 2 - 3/18/1951 (69) 12322344 CT View&GO CT View&GO Series CT View&GO SP F814.5 Head for dose calculation 1.50 Or40A2 Head for dose calculation 1.50 Qr40 A2 Add Study Benditos 3/1 8/2020 8:46:40 AM Structure Set_1 Current CT. 3/18/2020 NewReferencePoints RTP Head DE [factory](Adult) Favorite Tools InlineApp Sim&GO Patient Marking Laser Offset in IEC(cm) Table (mm) 1 Y Position Height X N 0 37 9 1.22 -379 135 Series Louer Man Beam Placement Printing v SP R38.8 Head for dose calculation 1.50 Or40A2 Head for dose calculation 1.50 Or40 A2 SP LO O Head for dose calculation 1.50 Qr40A2 Head for dose calculation 1.50 Or40 A2 RT Navigator 3/1 8/2020 8:46:40 AM 8:46:40AM 2 3 Structures POI Name Type NewReferencePo. ISOCE 4 < < . Absolute Offset IE X 0.00 Y -14 72 Z 87.90 cm OOK DEN 8:55 AM Step 3: Press Mark Patient (1). The laser will reach the Z- and X-position. SIEMENS Heatthineers syadmin + ? M & # = Scan 25 = Recon 2 - 3/18/1951 (69) 12322344 CT View&GO CT View&GO Series X CT View&GO SP F814.5 SP A147.2 Head for dose calculation 1.50 Or40A2 Head for dose calculation 1.50 Qr40 A2 Add Study Send and 3/1 8/2020 3/18/2020 Archive 8:46:40 AM 8:46:40AM Structure Set 1 Current CT. 3/18/2020 NewReferencePoints RTP Head DE [factory](Adult) Favorite Tools InlineApp Sim&GO Patient Marking Laser Offset in IEC(cm) Table (mm) × Y Z Position Height -3 88 -31.45 3145 135 1 Series amouring. 1.5 Beam Placement Printing 200 200 Absolute Offset IEC X -3.88 Y -15.42 Z 81.45 cm Set POI Move POI SP R38.8 SP A154.2 SP LOO Head for dose calculation 1.50 Qr40A2 Head for dose calculation 1.50 Or40 A2 Head for dose calculation 1.50 Qr40 A2 Head for dose calculation 1.50 Or40 A2 RT Navigator 3/1 8/2020 3/1 8/2020 8:48- 20AM 8:46:40 AM 8:46:40 AM 8 46 40 414 8 0 EncePoint Structures POI Name Type R NewReferencePo ISOCE 0cm 200 200 40 8:55 AM Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Page 2 of 5 Job Aid | Patient Marking Effective Date: 07/31/2020 | HOOD05162003102312 For the Y position, a move request for the table will appear at the bottom of the console. On the Patient Marking tab, you will see the coordinates. Step 4: Press the Play button at the hand control or at the control box (1). After the table has reached the defined position, the laser will automatically turn on. Healthingers syadmin - ? M Q = Scan 25 = Recon 2 Doe, Jane FD -3/18/1951 (69) 12322344 CT View&GO RTP Head DE [factor ... Tumm Topogram Patient Marking: Target Position . Head for dose calculation . Head for contouring Name Laser Offset in IEC (cm) Table Position (mm) Marked Reconstruction X Z Position Height Patient Marking NewReferencePoint1 -314.5 135.0 Close EC Coordinate System Message SIEMENS Healthineers The X (lateral) and Z (vertical) lasers have reached the target position. Press the MOVE key to move the table to the target position. 1 Please Complete Patient Marking Recor OK Cancel Press MOVE 8:55 AM Step 5: Once the laser and the table are in defined position, all values are green and you can mark the patient's skin physically. Step 6: After the patient is marked, click the Marked checkmark (1). syadmin - ? M # # = Scan 25 = Recon 2 - 3/18/1951 (69) 12322344 CT View&GO RTP Head DE [factor ... Topogram Patient Marking: Target Position Head for dose calculation . Head for contouring Laser Offset in IEC (cm) Table Position (mm) Name Marked Reconstruction Z Position Height Patient Marking NewReferencePoint1 1:32 1148 Close EC Coordinate System 1 Message The lasers and the table are at the target position. Mark the patient and then select the check box ] Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Page 3 of 5 Job Aid | Patient Marking Effective Date: 07/31/2020 | HOOD05162003102312 Step 7: Click OK to complete Patient Marking (1). syadmin - ? 4 0 = Scan 25 = Recon 2 Doe, Jane . - 3/18/1951 (69) 12322344 CT View&GO RTP Head DE [factor. Topogram Patient Marking: Target Position Head for dose calculation · Head for contouring Laser Offset in IEC (cm) Table Position (mm) Name Marked Position Reconstruction Height Patient Marking NewReferencePoint1 3145 Close EC Coordinate System Message The current isocenter has been marked Click OK to continue. Please C 1 ent Marking OK Cancel 8:56 AM Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Page 4 of 5 Job Aid | Patient Marking Effective Date: 07/31/2020 | HOOD05162003102312 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and exampl es only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Page 5 of 5
- somatom go
- gosim
- sim
- openpro
- opne
- pro
- por
- rt
- patient
- marking