Symbia QC Limits
This job aid cover the QC Limits for all Symbia Systems
Symbia Quality Control Acceptable Limits All Symbia systems This Job Aid contains the Nuclear Medicine Quality Control acceptable limits for recommended Daily, Weekly, and Monthly Symbia QC Procedures. Extrinsic Verification Flood (Daily) Uniformity CFOV UFOV Integral 5% 6% Differential 3.5% 4% Intrinsic Verification Flood (Weekly or Daily) Uniformity CFOV UFOV Integral 5% 6% Differential 2.5% 3% Restricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 SIEMENS Master Template: EFF Date 22 Aug 17 | HOOD/HILS HOOD05162002647849 Healthineers Job aid: Effective Date: 08/31/2021 | HOOD05162003213665 Job Aid | Symbia QC Schedule Effective Date:08/31/2021 | HOOD05162003213665 Multi-Head Registration - MHR (Monthly) Parallel Hole Collimators Center of Rotation < +10 mm Axial Shift < +5 mm Back Projection Angle < +0.8 degrees SMARTZOOM Collimators Center of Rotation < +20.0 mm Axial Shift < +5.0 mm Back Projection Angle < +2.0 degrees Principal Ray X and Y < +10.0 mm Principal Ray Angle X and Y < +5.0 degrees Long Focal Length X 4480 mm to 6268 mm Long Focal Length Y 4703 mm to 5837 mm Short Focal Length X 482 mm to 590 mm Short Focal Length Y 472 mm to 604 mm Restricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2021 Page 2 of 4 Job Aid | Symbia QC Schedule Effective Date:08/31/2021 | HOOD05162003213665 Intrinsic Calibration (Monthly) • Perform visual inspection to ensure there are no abnormal patterns such as spots or streaks. Uniformity Calibration can compensate for values up to 10%, but if Integral Uniformity exceeds 7%, contact your Siemens Customer Service Representative. Please note that the learning material is for training purposes only! Restricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2021 Page 3 of 4 Job Aid | Symbia QC Schedule Effective Date:08/31/2021 | HOOD05162003213665 For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (herein- after collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2018 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Restricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2021 Page 4 of 4
- QC
- Quality Control