syngo Aortic Valve Guidance: syngo Application Software VD20
syngo Aortic Valve Guidance syngo Application Software VD20 Using pre-procedure CTA data for planning Using DynaCT data for planning Load the CTA data. Start 3D Wizard and select an AVG Imaging program (alternatively use a 5s DCT Card DynaCT program). Start syngo Aortic Valve Guidance. Planning ✔ The aortic root is segmented automatically, and marked with the important anatomical landmarks. Switch between the perpendicular views to verify the positions. Optional: Measure the valve annulus diameter and area. Effective Date: 12.07.2018 | HOOD05162002976352 SIEMENS siemens.com/healthineers Healthineers VD20 Job Aid | syngo Aortic Valve Guidance Effective Date: 12.07.2018 | HOOD05162002976352 Overlay Select syngo 3D Roadmap (overlay live image to 3D image). Perform 2D/3D or 3D/3D registration. Rotate aortic root perpendicularly around centerline to find an optimal view, or select Rotate Aorta from the onscreen menu. +10 - mm Optional: Adjust the valve implantation height. Aortic Valve Guidance × Planning Select object list to define your shown objects. Overlay Rotate aorta to find optimal view. Adjust implantation height, if needed. Adjust C-arm to volume. Show Object Contour Centerline Commissure Lines Coronary Ostia I ... Cusp Nadirs Perpendicularity ... 10 mm X Select overlay objects to display the overlay on the live image. Color Live 4D Close Help Send the VRT angulation to C-arm (via 4D task card/touchscreen/Adjust C-arm in VRT onscreen menu). Move C-arm to match 3D image angulation. Select syngo 3D Roadmap (overlay live image to 3D image). Perform 2D/3D or 3D/3D registration. Siemens Healthineers Services Page 2 of 3 © Siemens Healthcare GmbH, 2017 VD20 Job Aid | syngo Aortic Valve Guidance Effective Date: 12.07.2018 | HOOD05162002976352 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (herein- after collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2019 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019
- syngo Aortic Valve Guidance: syngo Application Software VD20