syngo BreVis Biopsy

syngo BreVis Biopsy

syngo® BreVis Biopsy at the Scanner 1. Scan patient with fiduccial placement in C4 grid:  Note: Only fits into C4 grid when using the Sentinelle coil 2. Open Patient Browser:  Select > Patient study  Application > Select > BreVis: o Note: Series cannot be selected when using BreVis  Patient Browser re-opens after loading study: o Close > Patient Browser 3. BreVis image segments:  Coronal – upper left segment  Sagittal – upper right segment  Axial MIP – lower left segment: o Note: If the biopsy software is on the scanning console then key commands will not work 4. Select > Coronal segment:  Select >Tools tab Axial Orientation  Right mouse > Select > Rotation button > Select > Axial Coronel Orientation orientation Sagitta Orientation 5. Select > Workflow tab: Viewi .. Proce .. Tools Inter ..  Note: Walks the user through the biopsy steps 6. Select > Device dropdown > Select > Coil being used:  Note: user can make this a Default Selection at the bottom of the window Viewi .. Proce .. Tools Inter ..  Once coil is chosen: o Select > post/pillar or grid method Device Sentinelle Vanguard Intervention Method O Post / Pillar O Grid X Default Selection Confirm SIEMENS www.usa.siemens.com/healthcare Page 1 of 3 7. Select > Instrument/Needle Block dropdown:  Confirm > Needle device for biopsy: Note: If the same biopsy device is being used Viewi .. Proce .. Tools Inter o checkbox Default Selection Instrument Audio Black Suros ATEC Mi Lefont Edecken Confirm 8. Device calibration: • Scroll through images for fiducial location > Select > fiducial by left mouse clicking: o All image planes can be used for this step Fiducial Marker Detection o System recognizes fiducial location is in C4 Manuel > Select > Set Fixed 5ªt Cpt. • Type 0 for angle > Select > Confirm: Opt Andle o Note: If the grid is angled in the image, an offset can Confim be typed in to compensate 9. Plan depth of needle: • Scroll through Sagittal images until the impression of the grid is seen against the skin • Look at icon and ensure approach is correct (Lateral or Medial): o Select > Set o Select > Confirm Espree Access syngo i Direction Position Left Set Breast Side SPL FoV 21 Page 2 of 3 10. Scroll through images and locate the lesion:  Image can be changed to a subtracted data set by: o Selecting > Tools tab (or) Right mouse and select the value o Place crosshair on the lesion > Select > Lock Target  Select > Camera button to capture images for the targeted lesion Subtraction Settings Vorgate the crossher's to the Firget point: Printer Subtraction Mode Lode Target O Absolute Camera Relative O Original data Reference time point 1 OK Cancel 11. Select > Report tab > Double click on Intervention Report folder:  Select > Save tab: o Note: Report stored in Patient Browser and can be sent to PACS Results Report [601] Bre Vis Intervention SC 1 Intervention Report /11/E// / 5/10/2011 08:51:23 [602] Bre Vis Intervention SC 2 12. Starting Biopsy Planning Over – return to the beginning:  Select > Layout Tab > right mouse > Select “Reappy Layout” + 1 Reapply Layout Set as default Layout SIEMENS www.usa.siemens.com/healthcare Page 3 of 3