Syngo Composing Images
Syngo Composing Images
Syngo: Composing Images XPRF 1. If the “Composing” tab is not seen on the right side of the Syngo Workstation, go to “Applications”, select “AX”, and then choose “Composing”. Once the “Composing” tab is visualized on the right side, select the tab to activate “Composing”. Patient Applications Transfer Edit View Image Tools Scroll 2ptions Help AX Viewing Desktop Filming 2. Open the “Patient Browser” to manually load the desired images to be stitched. Select “Patient” from the top left, then select “Browser”. Patient | Applications Transfer Edit View Image Tools Options Help Browser Num . Search Search Selected ... Composing Selector F3 Save Close Patient Filming Layout ... Film Task Status ... Film Preview ... Expose Film Task Ctrl+P Copy to Film Sheet Num Enter Film All ... SIEMENS siemens.com/healthineers Healthineers Job Aid | Composing Images Effective Date: 10/08/2019 |Quality HOOD05162003043919 3. Locate the desired patient study, under the “Local Database”, and drag and drop the images into the “Composing” tab (in the background). Patient Applications Transfer Edit View Image Tools Options Help Viewing Patient Applications Transfer Edit View Filter Sort Private Applications Options Help - + VW G X Contents and Index ... F1 Filming View Manual Adjust [10] SPINE [11] SPINE Composing Local Database 2013 [12] SPINE Anonymous, Anonyn [13] SPINE Anonymous, Anonyn Tools Ortho | Orth R/// /// / Anonymous, CHEST R/ // / // / Anonymous, FOOT R/ / / / // / Patient name 2013 Date of birth - udy description Study date 10/14/2013 Patient ID 1383008366 Modality CR RF Current Filter: Off 4. If the “Composing Selector” does not automatically open, go to “Patient”, and select “Composing Selector”. Patient Applications Transfer Edit View Image Tools Options Help Browser .. Num . .... Search Search Selected Composing Selector F3 Save Close Patient ansfer Edit View Filter Sort t Private Applications Options Help Filming Layout ... Film Task Status .. Film Preview ... ? Expose Film Task Ctrl+P Copy to Film Sheet Num Enter 4 Film All. [10] SPINE 111/11 / [11] SPINE Local Database 2013 [12] SPINE Anonymous, Anonyn [13] SPINE R/// / / / / 111111 : Anonymous, Anonyn R/ // / / / / Anonymous, CHEST R/// /// / Anonymous, FOOT Patient name 2013 y description Date of birth - Patient ID 1383008366 H Study date 10/14/2013 Modality CR Siemens Healthineers Services Page 2 of 5 © Siemens Healthcare GmbH, 2017 Job Aid | Composing Images Effective Date: 10/08/2019 |Quality HOOD05162003043919 5. Within the “Composing Selector”, select all images, adjust the order if necessary, and then select the correct body part to be stitched. Composing Selector -- > 2013 -- Pat-ID: 1383008366 -- ??? -- O -- Exam: 10/14/2013 X Patient Edit View Image Sort Help IMA 1ª Series: 12 Image: Frame: 1 6. Enter TOD (Table Object Distance) when prompted. TOD must be entered for more accurate stitching. If the box does not display, verify “Show TOD dialog” is selected, under “View” within the “Composing Selector” box. Note: Measure the TOD for Spine exams from the Ortho stand to mid-spine. For long legs, always enter -1 as the TOD value. Composing Selector -- > 2013 -- Pat-ID: 1383008366 -- ??? Patient Edit View Image Sort Help ¥ Image Stripe Series Stack ........ .... SER 12 IMA 1 Show TOD dialog FRM 1 Siemens Healthineers Services Page 3 of 5 © Siemens Healthcare GmbH, 2017 Job Aid | Composing Images Effective Date: 10/08/2019 |Quality HOOD05162003043919 7. The images will automatically stitch; select the “Blend/Cut Mode” icon to verify the auto stitching is accurate. View Manual Adjust Position: X 2 8. If needed use the up/down and right/left arrows to adjust the image. Note: The top image is “fixed” and cannot be moved; adjust images 2, 3, and 4. View Manual Adjust Position: 2 9. Once all adjustments are made, select the “Blend/Cut Mode” icon to blend the image. Then select the “Save” icon to store the composed image. Note: It is Siemens recommendation to send the individual images along with the composed image to PACS. ilming View Manual Adjust Position: X 2 . Composing Tools Ortho | | Ortho Il Siemens Healthineers Services Page 4 of 5 © Siemens Healthcare GmbH, 2017 Job Aid | Composing Images Effective Date: 10/08/2019 |Quality HOOD05162003043919 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 5 of 5 © Siemens Healthcare GmbH, 2017
- Syngo Composing Images