syngo Congenital Heart Disease Guidance - syngo Application Software VD20
syngo Congenital Heart Disease Guidance syngo Application Software VD20 Using pre-procedure CTA or MRI data for planning Using DynaCT data for planning Load the CTA or MRI data. Start 3D Wizard and select the right program (alternatively use a 5s DR Card Care program). Start syngo Congenital Heart Disease Guidance. Planning Perform windowing and punching operations on the volume to display the anatomy of interest. Measurements are possible. You can mark anatomical landmarks in the volume. Dual volume functionality for 2 different anatomical structures (e. g. air path plus vessels) from the same volume. Activate the parallel range, change if you want the slice thickness. Save the volume; now 2 volumes are available. Open Browser again, mark both volumes and open them in the 4D Tab card using drag-and-drop (it is now a Dual volume visualization). Optimize the different volumes (VOI punching, coloring, etc.). 50- Display and Guidance Perform 2D/3D or 3D/3D registration. Align the VRT segment to an optimal working projection Move C-arm to match 3D image angulation. Select syngo 3D Roadmap (overlay live image to 3D image) to overlay 3D volume on fluoroscopy for guidance. This can be used to navigate with fluoroscopy, enabling you to position therapeutic devices to the desired locations. During the procedure: Mark anatomical landmarks or perform measurements, if necessary. Effective Date: 12.07.2018 | HOOD05162002976352 SIEMENS siemens.com/healthineers Healthineers VD20 Job Aid | syngo Congenital Heart Disease Guidance Effective Date: 12.07.2018 | HOOD05162002976352 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (herein- after collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2019 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019
- syngo Congenital Heart Disease Guidance - syngo Application Software VD20