syngo.CT VB20 - Radiation Oncology - Software Update Job Aid
SIEMENS Healthineers CT SOMATOM VB20 Radiation Oncology Template Effective Date: 01/08/2018 | HOOD05162002751995 Job Aid Effective Date: 10/01/2019 | HOOD05162003039972 Effective Date: XX/XX/XXXX | HILS/HOOD# Unrestricted Unrestricted © Siemens Healthcare GmbH, 2019 Unrestricted © Siemens Healthcare GmbH, 2019 Radiation Oncology syngo CT VB 20 – SIEMENS Healthineers Table of Contents DirectBreathhold* 3 HD FoV 4 SIEMENS Healthineers DirectDensityTM* 6 New Scan Protocols for RO & auto transfer 7 OMATOM Confidence * Optional 2 Effective Date: XX/XX/XXXX | HILS/HOOD# Unrestricted © Siemens Healthcare GmbH, 2019 DirectBreathhold* SIEMENS Healthineers DirectBreathhold simplifies DIBH (Deep Inspiration Breath Hold) CT RT Head RT Head IR lenc acquisition by automatically triggering the prospective scan. It may help to RT DE Head RT_HeadNeckShoulder reduce unwarranted variations in respiratory scans. RT HeadNeckShoulder IR RT_DE_HeadNeckShoulder RT Thorax RT_Thorax_IR 1. Configure the gating device and select the „Trigger (ANZAI)“ or „DeepBreathHold Mode (Varian)“. RT Abdomen RT Abdomen IR an RT_Pelvis 2. Train correct breathing/ breathhold with the patient. RT Pelvis IR RT_RespSeq 3. Select the NEW „RT_RespBreathHold“ protocol and scan the topogramm and plan the scan. RT RespSea IR RT_RespBreathHold 4. Start the scan and give the breathing commandos to the patient (or define them in the protocol). RT_RespBreathHold_IR RT_Resp RT Resp_IR 5. Scan starts as soon the system receives the trigger signal coming from the respiratory gating system (e.g. RY JUU mA 20 GTOO RGSC or ANZAI). Note: The system will start after a short delay to assure compliance of the patient with the 512 0/0 Tr20.10n WOPO.11. M -10242 738 RT_RespBreathHold (Adult) VB20 VB20 Total mAS: 36 breathhold threshold. Topogram E# MAS CARE DO504D Thorax RT KV 120 CTDivol (32cm):: 0:54 moy DUR 7.52 mey'cm Scan ome 335 5 6. After the scan inform the patient that normal breathing can followed. Deley Sice e 30 mm Aco 16x 1.2mm Caution: No of images Automatic stop of the scan after 3 min, in case no trigger signal is received. Comments In case the patient leaves the breathhold threshold, coughs or other breathing issues occur, Range: Begin End Table Position Hoight Suspend Recon -1895 0 -2015 0 -18700.J 1000 Craniocaudal Canpol the system will continue with the scan – a manual interruption is possible at any time. Routine Scan Recon Auto Tasking Prerequisite for the DirectBreathholdis Respiratory Motion Management as well as an external gating device that can trigger the scan (e.g. RGSC/ANAZI). * Optional Direct Fast 4D – 3 Breathhold Overview Effective Date: XX/XX/XXXX | HILS/HOOD# Unrestricted © Siemens Healthcare GmbH, 2019 Enable visualization up to the bore size with HD FoV SIEMENS Healthineers Standard Scan Field of View (FoV): 50 cm Bore size Full reconstruction 50 cm HD Field of View Pro: Up to the bore size Designed to enable visualization of the human body parts and skin line located outside of the 50 cm standard scan field of view up to the bore size, based on an algorithmic complement of missing detector data outside of the 50 cm standard scan FoV1. Validation of HD FoV Scans with a Gammex tissue characterization phantom show HU accuracy of up to +/-20 HU and a skin line accuracy of up to +/- 2 mm up to the bore size1,2,3 1. The image quality for the area outside the 50 cm standard scan field of view does not meet the image quality of the area inside the 50 cm standard scan field of view. Image artefacts may appear, depending on the patient setup and anatomy scanned. 2. As demonstrated in phantom measurements employing the Gammex 467 phantom; clinical results may vary. For further information, see Whitepaper: 50 cm ...... HD FoV - Technical principles and phantom measurements evaluating HU accuracy and skin-line accuracy in the extended field of view (FoV) region in Computed Tomography (syngo CT VB10 and VA20); Mistry et al.; 2018 Bore size 3. Results from validation can only be reproduced with a Gammex 467 phantom position, that equals the positioning used in the white paper. A modified test set up can lead to different results. HD FOV 4 Effective Date: XX/XX/XXXX | HILS/HOOD# Unrestricted © Siemens Healthcare GmbH, 2019 HD FoV – changes from VB10 -> VB20 SIEMENS Healthineers 500 mm VB20 HD FoV 500 mm 500 mm 500 mm VB10 HD FoV 500 mm 500 mm HD FOV 5 Effective Date: XX/XX/XXXX | HILS/HOOD# Unrestricted © Siemens Healthcare GmbH, 2019 DirectDensityTM* (2.0): incl. Mass Density SIEMENS Healthineers DirectDensity™ eliminates the dependency between CT values and kV 70 100 140 KV KV KV With syngo CT VB20 (onwards) DirectDensityTM does not only offer relative electron 80 KV 120 ......... KV ............. density, but also mass density directly in the CT image. This helps RT customers ............................. avoiding additional efforts in calculating mass density for treatment planning. -O • Both, electron and mass density are independent of kV and pre-filtration Recon job 2 3 4 5 6 8 Series description Abdomen 3.0 Sm40 eDDensity (Kernel: Sd40): name of the reconstruction variant, where the Slice 3.0 mm Recon job type o Axial 3D • ADMIRE Recon region: Narrow . Wide . physical property is the electron density 𝜌𝜌_𝑒𝑒. Kernel Sm40 None FAST Window Abdomen Begin position -1828.0 mm mDDensity (Kernel: Sm40)*: name of the reconstruction variant, where A End position 2028.0 mm ......... • E ... 62 @- Vascular the physical property is the mass density 𝜌𝜌. · Head Image order Craniocaudal + Quantitative Increment 3.0 mm Overview B- Special Artificial120 No. of images 67 • DirectDensityTM now also supports TPS (treatment planning systems) Mirror Body Comments + eDDensity 14 ..... Extended d that base dose calculation on mass density, e.g. monte carlo algorithm + . Head Routine E mDDensity ..... 40 Auto Tasking based TPS. E- All *Note: Customers having current DirectDensityTM license (VB10) will receive the new license FOC (free of charge) with the upgrade to VB20. *Optional 1) Optional; DirectDensity™ reconstruction is designed for use in Radiation Therapy Planning (RTP) only. DirectDensity™ reconstruction is not intended to be used for diagnostic imaging. As shown by measurements with a Gammex 467 Tissue Characterization Phantom comparing standard reconstruction (kernel Qr40) and DirectDensity™ reconstruction (kernel Sd40/Sm40). Image value to relative electron/mass density conversion for the standard reconstruction was based on a two- linear-equations approach with individual calibration for each tube voltage. For DirectDensity™ images, a single tube-voltage-independent linear conversion was used. Direct 6 DensityTM Effective Date: XX/XX/XXXX | HILS/HOOD# Unrestricted © Siemens Healthcare GmbH, 2019 Radiation Therapy SIEMENS Healthineers NEW protocols and tMIP/tMIN autotransfer syngo CT VB20 brings new protocols: RT Head RT Head IR ence l Benefit from an increased FOV for dual spiral DE protocol – now up to RT DE Head 500 mm, as well as from an easy DIBH acquisition with DirectBreathhold St RI_HeadNeckShoulder RT_HeadNeckShoulder IR RT_DE_HeadNeckShoulder RT Thorax RT_Thorax IR RT DE Head & RT HeadNeckShoulder RT Abdomen RT Abdomen IR angu DE Scan Protocol with a FOV of 500 RT Pelvis • RT Pelvis IR Beneficial for e.g. Head and Neck scans including shoulders and/or masks RT RespSeq • RT RespSea IR RT_RespBreathHold RT_RespBreathHold IR RT_RespBreathHold & RT_RespBreathHold_IR RT_Resp_IR • Triggered prospective spiral (p. 5) • Breathing comments needs to be done manually or can e defined in the protocol not by Recon job ! 2 3 4 5 6 7 8 Sies description [Resp 3.0 Br38 100 % Ex . 80 % In default in the protocol defined Auto recon Auto filming IM wyimage Auto viewing No, of fimed images0 Auto postprocessing None None Auto reference lines [-MinIP t-MaxP Note: tMIP/tMIN autotransfer* Auto transfer None Requested procedure [RT RT_Resp (Adut) None None Body part examined Chest • With the new software version syngo CT VB20 the auto transfer of the auto generated tMIP/tMIN is enabled, now. Routine Scan Recon *For more DE related changes e.g. new FAST DE results, please refere to the CT Somatom VB20 PEPconnect Document. Auto Tasking Trigger New Scan 7 Protocols Effective Date: XX/XX/XXXX | HILS/HOOD# Unrestricted © Siemens Healthcare GmbH, 2019 SIEMENS Healthineers Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2019 Global Siemens Healthineers Headquarters Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84 0 siemens.com/healthineers 8 Effective Date: XX/XX/XXXX | HILS/HOOD# Unrestricted © Siemens Healthcare GmbH, 2019
- syngo.CT VB20 - Radiation Oncology - Software Update Job Aid