syngo CTO Guidance - syngo Application Software VD20
syngo CTO Guidance syngo Application Software VD20 Using pre-procedure CTA data for planning Load data from a previous CTA. IS Start syngo CTO Guidance. Guidance ✔ Guidance workflow step is selected automatically. ✔ The coronary vessel tree is automatically segmented. The centerlines are color-coded. Identify Vessels Create refined parts of the segmented vessel tree, if necessary. Add or delete vessel branches, or reposition centerlines, if necessary. [Geben Sie ein Zitat aus dem Dokument oder die Zusammenfassung eines interessanten Coronary Analysis (optional) Punkts ein. Sie können das Textfeld an einer Analyze a single vessel segment or perform distance measurements, if necessary. beliebigen Stelle im Dokument positionieren. Verwenden Sie die Registerkarte 'Zeichen- tools', wenn Sie das Format des Textfelds Registration (optional but highly recommended) 'Textzitat' ändern möchten.] For stronger synchronization between CTA data and the C-arm movements, table position, SID and zoom factor Perform 2D/3D registration. Acquire two different angulations of the coronary tree (recommendation: 45° RAO/45° LAO). Accept 2D/3D. Perform recanalization of the blocked artery via PTCA. ✔ COROwave shows the color-coded centerlines, which indicates foreshortening of current segment and automatically follows the C-arm angulation. Alternatively, adjust the C-arm position according to the COROwave. If you are using a biplane C- arm system, the COROwave is adjusted to the recently used plane (A or B). In addition, it shows a simultaneous visualization of two COROwave segments for biplane acquistion. CTA information is shown side-by-side to the live fluoro images for optimal guidance. Select syngo 3D Roadmap (overlay live image to 3D image) to overlay 3D volume on fluoroscopy for guidance. Effective Date: 12.07.2018 | HOOD05162002976352 SIEMENS Healthineers siemens.com/healthineers VD20 Job Aid | syngo CTO Guidance Effective Date: 12.07.2018 | HOOD05162002976352 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (herein- after collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2019 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019
- syngo CTO Guidance - syngo Application Software VD20