syngo Dynamics VA40 SysAdmin Delta Online Training - USA
This online training module will introduce you to the new features and feature improvements available in SysAdmin with syngo Dynamics VA40.
Continue Continue SysAdmin syngo Dynamics VA40 SysAdmin Delta Online Training This online training module will introduce you to the new features and feature improvements available in SysAdmin with syngo Dynamics VA40. Master Template HOOD05162003052540 | Effective Date: 26-Nov-2019 Auto Lock out 1 Soft template check-in 3 Privileges 2 Welcome Audio Filename: sd_va40_sysadmin_welcome.mp3 Audio Script: Welcome to the syngo Dynamics VA40 SysAdmin Delta Online Training. This online training module will introduce you to the new features and feature improvements available in SysAdmin with syngo Dynamics VA40. Upon successful completion of this module, you will be familiar with the new options available within System Administration. Please note that this Online Training module should not be seen as a replacement to onsite application training. This training serves as a preparation to your onsite applications training. Let’s get started. System Administration syngo Dynamics System Administration (SysAdmin) allows you to configure key settings. In this module you will be introduced to the new features and feature improvements of SysAdmin in VA40: Auto lock out Privileges Soft template check-in System Administration Auto lock out As a security enhancement, in VA40 you can configure a lock out for SysAdmin users for failed login attempts. As the System Administrator, you configure the threshold for consecutive failed login attempts within a configured timespan in the Local Security Policy. Here you configure the following settings: Account lockout threshold: number of failed login attempts. Reset account lockout counter: the time period in which the failed login attempts occur. Please consult with your facility’s Server Administration team for further information. Auto lock out Auto lock out: example Configuration in Local Security Settings: Account threshold: set to three Reset account lockout counter: 15 minutes In this example, a user will be locked out after three consecutive failed login attempts within 15 minutes. When the login attempt threshold is exceeded, the user receives a message to contact their System Administrator. Auto lock out: example Resolve auto lock out SysAdmin User: Reset the password for the user in Users. A successful log in will reset the failed login counter and time window. Security Admin user: Please contact Siemens Healthineers Service. Resolve auto lock out Auto lock out Applications This enhancement applies to the following applications: Data Mining Application (DMA) SysAdmin Server Configuration Tool Patient Exclusion Tool Fax Log Viewer Database API Workplace HL7 Reconciliation Tool Password entry during verifying a report, marking a study as read, or marking a study as unread Service tools Auto lock out Applications Privileges Newly added privileges determine access to: SysAdmin tabs Data Mining Database API syngo Dynamics WebViewer These privileges should be reviewed and assigned to the appropriate groups as determined by the System Administrator. To view a list of newly added and removed privileges, click here. Privileges Table with 2 columns and 1 rows Newly added privileges: Addend Verified Reports Access Scheduled/Arrived Studies Access SysAdmin ‘Department’ Tab Access SysAdmin ‘License’ Tab Access SysAdmin ‘Site Ids’ Tab Access SysAdmin ‘Other Servers’ Tab Access SysAdmin ‘Users’ Tab Access SysAdmin ‘Privileges’ Tab Access SysAdmin ‘Study Types’ Tab Access SysAdmin ‘Templates’ Tab Access SysAdmin ‘Reports’ Tab Access SysAdmin ‘Fax’ Tab Access SysAdmin ‘Measurement’ Tab Access SysAdmin ‘Export’ Tab Access SysAdmin ‘Custom Export’ Tab Access SysAdmin ‘Integration’ Tab Access SysAdmin ‘Diagram Import’ Tab Access to fax log viewer Use Data Miner Use Remote Access Removed privileges: Cache Studies Locally Full Access Patient Jacket Read-only Patient Jacket Privileges Soft Template Check-in With VA40 you have the ability to check in templates without forcing users to log off. When you check in the templates, users that are currently logged in receive a message notifying them that new templates are available. Users can continue to review images, perform measurements and complete reports. The template can be updated as required, inline with their current workflow. The following slides demonstrate how to update the template depending on your current workflow status. Soft Template Check-in When a new study is opened, the updated report and worksheet templates are applied. Soft Template Check-in: Open at Study List Open at Study List Audio Filename: sd_va40_sysadmin_stc_01_open-study.mp3 Audio in Video: If there is no previous report for a study, the worksheet and report templates update when you open the study. Select the study from the study list. When you open the report and worksheet the templates are updated to the new templates. The word Updated is displayed here in the title for the purpose of this demonstration. Study Open in Image Review Select the numbered steps below to learn about updating the template if you have the study open in Image Review when the check-in occurs. 1 1 1 2 2 2 3 3 3 Study Open in Image Review Audio Filename: sd_va40_sysadmin_stc_02_template-dialog.mp3 Audio in Video: If you have the study open when template check-in occurs, a template dialog is displayed. Accept the message. You can continue to work uninterrupted. If you would like to use the updated templates, you can update them at a later time as your workflow allows. Audio Filename: sd_va40_sysadmin_stc_03_close-reopen.mp3 Audio in Video: If you would like to update the template for a study that was opened during the check-in, you must close and open the study. Closing and re-opening the study, updates the worksheet and the updated definitions in the Calc palette. The report template is not automatically updated. To update the report template to the new template, you must replace the report. Select Replace Report from the menu in the bottom left corner. Select the report that you would like to use as a replacement. A dialog appears. Select Change Template. The report template is updated to the selected template. Close/reopen the study When you close and re-open the study: The worksheet is updated. The definitions in the Calc Palette are updated. To update the report: You must replace the report. 3 When you open the report and/or worksheet, the updated Worksheet is displayed and the outdated Report is displayed. A message is shown to notify you that the templates have been updated. Templates are locked and are not editable. The study must be closed and reopened in order to edit templates. Open the Report/Worksheet 2 The template dialog box is displayed You can continue to review images, perform measurements and complete your report. 1 Study Open in Image Review and Reporting Select the numbered steps below to learn about updating the template if you have the study open in Image Review and Reporting when the check-in occurs. 1 1 1 2 2 2 3 3 3 Study Open in Image Review and Reporting Close/reopen the study When you close and re-open the study: The worksheet is updated. The definitions in the Calc Palette are updated. To update the report: You must replace the report. 3 Continue to work on the original or new template No message is shown below the worksheet and report. If desired, you can continue to work on the original worksheet template and report. If you would like to use the new templates, you must close and re-open the study and replace the report. 2 The template dialog box is displayed If the study was opened in Image Review and Reporting when the template check-in occurred: The template check-in dialog is displayed. Accept the message. 1 Course Review Congratulations. You have completed the syngo Dynamics VA40 SysAdmin Delta Online Training. Select the objectives listed below to review the material before proceeding to the final assessment. Additionally, a full course review is available in the Resources tab. 1 1 1 Auto Lock out 3 Soft template check-in Privileges 2 2 2 Course Review Soft template check-in With Soft Template Check-In enhancement, templates may be checked in even if users are logged in and studies are open. A message appears notifying them that new templates are available. Users can continue to review images, perform measurements and complete reports. The template can be updated as required, inline with their current workflow. Privileges Newly added privileges determine access to: SysAdmin tabs Data Mining Database API syngo Dynamics WebViewer Auto lock out Users will be automatically locked out if they have exceeded the configured “account threshold” for login attempts within the configured span of “reset account lockout counter”. As the System Administrator, you configure the threshold for consecutive failed login attempts within a configured timespan in the Local Security Policy. Here you configure the following settings: Account lockout threshold: number of failed login attempts. Reset account lockout counter: the time period in which the failed login attempts occur. Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters / Siemens Healthcare GmbH / Henkestr. 127 / 91052 Erlangen, Germany Telephone: +49 9131 84-0 / www.siemens-healthineers.com Disclaimer Disclaimer Assessment This assessment will test your retention of the presented content. A passing score of 80% or higher is required to complete the course and earn your certificate. You may repeat the assessment as many times as needed. Start Assessment Users Tab Local Security Policy Privileges Templates Tab In VA40 you can configure an Auto Lockout for consecutive failed login attempts within a configured timespan. Where do you configure the Auto Lock out? Question 1 of 5 Select the best answer. Question 1 Incorrect You manage Templates in the Templates tab. Incorrect You assign Privileges to groups in the Privileges tab. Incorrect Correct You manage individual users in the User tab. Log in to SysAdmin and reset the account password. Create a new User account for the locked user. Ask the user to wait 15 minutes and try to log in again. Contact your Siemens Healthineers Service Representative. How do you resolve an Auto Lock out for a general (non Admin) account? Question 2 of 5 Select the best answer. Question 2 Incorrect It is not necessary to contact Siemens Healthineers. You can resolve the lock out. Incorrect You cannot wait for the lock out to resolve. Incorrect It is not necessary to create a new account. It is possible to resolve the lock out. Correct Log in to SysAdmin and reset the account password. Create a new account. Wait 15 minutes and try to log in again. Contact your Siemens Healthineers Service Representative. How do you resolve an Auto Lock out for an Admin account, if you are the only Administrator? Question 3 of 5 Select the best answer. Question 3 Incorrect Incorrect You cannot wait for the lock out to resolve. Incorrect If you cannot log in, you cannot create a new account. Correct If you cannot log in, you cannot reset the account password. The user is forced off syngo Dynamics. The user receives a message that new templates are available. They must update the templates immediately. The user receives a message that new templates are available. They can continue to work and update the templates as desired. In VA40, what happens when a user is logged in during template check in? Question 4 of 5 Select the best answer. Question 4 Incorrect Incorrect The user can continue to work with the previous templates if required. Correct The user is not forced off syngo Dynamics during Template check in. No action is required, the report is automatically updated. Open and close the study. Open and close the study and replace the report. If you have the study open during template check-in, what do you do to access the new report? Question 5 of 5 Select the best answer. Question 5 Correct Incorrect The report is not automatically updated if you open and close the study. Correct The report is not automatically updated if you have the study opened. Review Review Retry Assessment Results %Results.ScorePercent%% %Results.PassPercent%% Continue YOUR SCORE: PASSING SCORE: Assessment Results You did not pass the course. Take time to review the assessment then select Retry to continue. Congratulations. You passed the course. Exit To access your Certificate of Completion, select the Launch button drop down on the course overview page. You can also access the certificate from your PEPconnect transcript. You have completed the syngo Dynamics VA40 SysAdmin Delta Online Training. Completion HOOD05162003098149 | Effective Date: 10-JUN-2020 Course Review 1.1 Welcome 1.2 System Administration 1.3 Auto lock out 1.4 Auto lock out: example 1.5 Resolve auto lock out 1.6 Auto lock out Applications 1.7 Privileges 1.8 Soft Template Check-in 1.9 Open at Study List 1.10 Study Open in Image Review 1.11 Study Open in Image Review and Reporting 1.12 Course Review 1.13 Disclaimer 1.14 Assessment 1.21 Completion
- SysAdmin