syngo Dynamics VA40 Workplace Delta Online Training - USA
This Online Training module introduces you to the new features and feature improvements available with syngo Dynamics VA40.
Continue Continue Workplace syngo Dynamics VA40 Workplace Delta Online Training This Online Training module introduces you to the new features and feature improvements available with syngo Dynamics VA40. Master Template HOOD05162003052540 | Effective Date: 26-Nov-2019 syngo Dynamics Workplace 1 syngo Dynamics WebViewer 3 syngo Dynamics Remote Workplace 2 Welcome Audio Filename: sd_va40_workplace_welcome.mp3 Audio Script: Welcome to the syngo Dynamics VA40 Workplace Delta Online Training. This Online Training module introduces you to the new features and feature improvements available with syngo Dynamics VA40. Upon successful completion of this module, you will be familiar with the changes made in the syngo Dynamics Workplace, the new syngo Dynamics Remote Workplace as well as the syngo Dynamics WebViewer, and see which third-party applications are supported in VA40. Let’s get started. syngo Dynamics New Features and Improvements In this chapter you will be introduced to the new features and feature improvements of syngo Dynamics Workplace and the Remote Workplace. syngo Dynamics New Features and Improvements User Interface Design The syngo Dynamics user interface has been redesigned to bring alignment across the syngo Dynamics Workplace, the syngo Dynamics Remote Workplace and the syngo Dynamics WebViewer. The same Study List is available on the Workplace, the Remote Workplace and the WebViewer. User Interface Design Common Study List Redesign Common Study List Redesign Audio Filename: sd_va40_workplace_csl-redesign.mp3 Audio in Video: The common study list has been redesigned in VA40 to be consistent between the Workplace, Remote Workplace and the WebViewer. Canned search queries have been moved to the top left of the screen. This can include your saved queries for quick reference. Field Search has been replaced and improved with Advanced Search. Quick Search has been expanded to include searching by Patient Name (separated by a comma), Patient ID, MPI, Accession Number, Study Type, Date of Birth, and Study Dates. The Department/Server dropdown list has moved to the right of the Quick Search. There is now a manual Refresh icon. The “Assign To” physician has moved to the upper right corner. A new Locked column displays a lock icon when another user has the study open. A new PDF column allows you to view a created PDF report without opening the study. The new Column Chooser allows you to show/hide and rearrange columns. You can configure the syngo Dynamics Workplace using the Settings icon in the top right corner. Create custom contextual search queries Save your custom queries Edit and Delete your custom queries Advanced Search Advanced Search Audio Filename: sd_va40_workplace_advanced-search.mp3 Audio in Video: In VA40, the Field Search function has been replaced and improved with Advanced Search. Advanced Search enables you to create your own contextual search query. For example, you can create a search based on a range of dates, based on an exact patient name or site ID, or based on several letters contained in a patient’s name. You can save the custom queries for future use. Enter a name for the search and select Save. Custom queries are saved and remembered per user. You access the saved queries from the drop-down list in the canned search section. If required, you can also modify or delete a saved query. Select the saved Query from the list. Select Delete. The Query is now deleted. Study List Columns can be visible or hidden Modify the order that the Study List columns are displayed Column Chooser Column Chooser Audio Filename: sd_va40_workplace_column-chooser.mp3 Audio in Video: You can customize your study list using the Column Chooser functionality. The changes are applied to your user setting and will be displayed the same in the Workplace, Remote Workplace and WebViewer. Select the icon in the bottom left corner of the Study List. The left side displays currently displayed columns. The right side contains columns that are not currently displayed. Click on the minus symbol to hide the column. Click on the plus symbol to make the column visible on the study list. You may also hide all columns or make all columns visible. To modify the position of a column, simply select the column name and drag it up or down to the desired position. Select OK to exit and save your preferences. The columns are now displayed with your new preferences. Many previous menu options have been moved, removed or are no longer available New options added Study List File Menus Study List File Menus Audio Filename: sd_va40_workplace_sl-file-menus.mp3 Audio in Video: The Study List File Menus have been updated in VA40. Many of the options have been moved to a different location within the application, have been removed from the menu, or are no longer available within syngo Dynamics. For example, the options in the Patient and Study menus have been simplified. The third-party App launcher is still located in the Utilities Menu. Select the question mark icon to access the Help menu. Here you will find access to the User manual, Release notes and your current software version. There are some new options, such as Settings that allows you to manage account settings. New (n:1) Layout With the new n:1 layout, your syngo Dynamics workplace can display as many images possible at a time. The number of images possible depends on your screen resolution. The n:1 layout is available for all non-stress echo images. To select the n:1 layout, click the layout icon in your toolbar. New (n:1) Layout Thumbnails In VA40 the availability of thumbnails has changed. Max and Full display: thumbnails are available. Split display: thumbnails are not available. Click on the icon in the top right in Image Review to activate the thumbnails pane. Thumbnails Right-Click Context Menu & Study Utilities File menus have been removed from within image review. Image related tasks have been moved to the Right-Click Context Menu. Study related tasks (Split and Merge) have been moved to the Study Utilities Icon. Right-Click Context Menu & Study Utilities Measurement Tools in upper right corner Image Tools in lower right corner Tooltips provide details about each tool Click here to see a list of the icons Corner Menus Corner Menus Audio Filename: sd_va40_workplace_corner-menus.mp3 Audio in Video: The Tools are available in the top right and bottom right of the image. The Tools remain hidden unless you move your mouse cursor to them. Move your mouse to the top right of the image to display the Measurement Tools. When you hover your cursor over the icon, the tool tip appears. The Measurement Tools available depend on the image type. For example, for XA images, only the 2D Distance measurement tool is available. At the top you will find the icon to open the Calc Palette. Image Tools are located in the bottom right of every image. Move your mouse over the lower right of the image to display the Image Tools. Here you will find Tools for image display and post processing. The Image Tools available depend on the image type. For example, Edge Enhancement is only available for XA images and the Calibration Tool only appears if the image was not previously calibrated. syngo Dynamics VA40 Tool Icons Table with 6 columns and 6 rows Calibration Tool Peak Velocity Annotations Open the Calc Palette Ellipse Tool Blackout Tool 2D Distance Show/Hide Taken Measurements Window/Level 2D Method of Disk Edge Enhancement Zoom & Pan 2D Trace & Doppler VTI Select the Frame to Mask Display Mask Frame Angle Contrast/Brightness (Gamma) Zoom and Pan Zoom and Pan Audio Filename: sd_va40_workplace_zoom-pan.mp3 Audio in Video: To activate Zoom and Pan tool, move the mouse to the bottom of an image to display the Image Tool and select the Zoom icon. Move the slider up or down to adjust the image zoom. To pan the zoomed image, click and hold the mouse scroll wheel and move the mouse in any direction. At any point, when you release the button wheel, the image stops panning. You can perform measurements on the zoomed image. You can also add annotations and black box regions to a zoomed image. The pan and zoom changes are not saved with the study. Calculations and Measurements available from Calc Palette icon Color-coded values for easier differentiation Clicking a measurement takes user to the specific frame containing that measurement Calc Palette Calc Palette Audio Filename: sd_va40_workplace_calc-palette.mp3 Audio in Video: If you have the Cardiac Echo and/or Vascular Quantification Package, you can view and add Calculations and measurements using the Calc Palette. The Calc Palette displays the measurements and calculations defined on the Measurements Tab in SysAdmin for the study type. A list of all measurements configured in the Measurements and Calculation library in Report Designer is available under the All measurement set. This list is not available for edit in SysAdmin. The Calc Palette is supported for Ultrasound studies for the following calculation types: Cardiac, Vascular, and General. To open the Calc Palette click the icon on either the Toolbar or from the Corner Menu. Alternatively, you can open the Calc Palette by pressing the Function and F4 keys on your keyboard. The Calc Palette remembers the last state (open or closed). This preference is maintained for your subsequent sessions. Navigate to the measurement you want or use the Search Field to search for the measurement. When searching if the drop-down list is on a measurement set, only those values which were defined in SysAdmin for the measurement set will be available in the search. To display All measurement sets click on the drop-down list. Measurement sets can be customized to view measurements and calculation results (such as ejection fractions) without having to open the worksheet. The value seen next to the label in the Calc Palette is the derived value and appears in a yellow color. The derivation method is displayed in a tool tip when hovering over this value. If multiple instances of a measurement were taken you can view those individual instances by selecting the label of a measurement in the Calc Palette to reveal the instance dialog at the top of the Calc Palette. Values are color coded to help differentiate between derived values which populate the report, transferred DICOM Structured Reporting measurements, and measurements entered directly into syngo Dynamics. You can draw Measurements on images in Image Review. The Measurement appears in the Calc Palette. If a measurement was created from the Calc Palette or if the Measurement was assigned from the Data Display Box (DDB), upon using a generic measurement you can modify, exclude and delete the measurement. For measurements taken in syngo Dynamics you can locate the image and frame where the measurement was performed. To do this click on the measurement label in the Calc Palette to display the instance dialog at the top of the calc palette and click on a single instance (green value). If required, you can modify the drawn measurement on the image to change the output. When you hover over a measurement label in the Calc Palette, a Tooltip is displayed that shows the Database name. If the measurement has more than one instance of a measurement it shows the derived value of that measurement. You close the Calc Palette by clicking on the (X) button in the corner, or by pressing the F4 key on your keyboard. Image Navigation (Mouse Functions) Image Navigation (Mouse Functions) Audio Filename: sd_va40_workplace_image-navigation.mp3 Audio in Video: In VA40 there are some modifications and enhancements to image navigation. In previous versions, you Right-click to start and stop a video clip. In VA40, you Right-click to open the Context Menu. From the Context Menu, you can Start or Stop the selected clip or Start or Stop all clips from playing. Alternatively, you can Left click on the image to start and stop clips playing. You can no longer use a Left-click to scroll through frame by frame. However, the video control bar along the bottom is still available, and you can use this to scroll through frame by frame. With the clips playing you can use the mouse wheel to advance to the next page of images. Additionally, if the video clip is stopped, you can use the mouse wheel to navigate frame by frame. To avoid accidentally selecting images, you now must use Ctrl + Left-click to select or deselect images. You can select All images in the Context Menu. The Context Menu is opened by Right-clicking on the image. Alternatively, you can use Ctrl + A on your keyboard to select All images. To deselect all images, press Ctrl + D on your keyboard. Formerly known as “Selected Images” No Placeholders 2 Methods to flag images Key Images (Method 1) Key Images (Method 1) Audio Filename: sd_va40_workplace_key-images-method1.mp3 Audio in Video: Formerly known as Selected Images, the Key Image feature has been enhanced in syngo Dynamics VA40. Previously, placeholders were displayed based on the selected layout. In VA40, the selected images screen is not limited to a fixed number and the placeholders are no longer necessary. If the number of key images exceeds the layout value, you can use the scroll bar, the Page down and Page up keys on your keyboard or scroll with the mouse wheel to display additional images. If no images are selected as Key Images, the screen is blank. Select the images that you would like to add to Key Images. There are two methods to flag images as a key image. For the standard method, you single-click on the thumbnail. Selected images display with a white border to indicate they are currently displayed in the key images view pane. You can replace existing key images by drag-and-drop. The image being replaced has a green border. You can also use the drag and drop feature to place a new key image in-between two existing key images. A green target line separating the two existing key images display, indicating the location the new key image will be inserted. Select key images on-the-fly during interpretation After clearing all key images, make sure to select “All Images” before leaving the Thumbnails arena Key Images (Method 2) Key Images (Method 2) Audio Filename: sd_va40_workplace_key-images-method2.mp3 Audio in Video: You can also select Key Images on-the-fly during image review. Select the image you want from the review pane. Right-click to open the Context Menu. Here you can save the current image, or all selected images as Key Images. To view the Key Images, select Thumbnails and Key Images. To remove images from the Key Images, right-click and select Remove From Key Images. You can remove the current images, selected images or ALL images. Please note that if you clear all of your key images and turn off thumbnails, you will not see any of your study images. The system still has Key Images selected behind the display. Make sure you select “All Images” before leaving the Thumbnails arena. Then you will be able to again see all your study images when you turn off Thumbnails. syngo Dynamics Workplace The syngo Dynamics Workplace allows you to view images on a wide variety of display hardware. syngo Dynamics Workplace is the full-fledged application displaying full DICOM images. In this chapter you will be introduced to the new features and feature improvements of syngo Dynamics Workplace (only). syngo Dynamics Workplace Exporting Studies Exporting Studies Audio Filename: sd_va40_workplace_exporting-studies.mp3 Audio in Video: Exporting studies has been enhanced in VA40. To export a study, first select the desired study. Select the Study Menu and then click on Export Studies To. If your system is licensed, you can export studies from your syngo Dynamics workplace to external sources such as external hard drives, local drives, mapped network drives, CD/DVD and USB. Alternatively, you can export to a File system. After you select Export, you will receive a new PHI information recommendation. Select Continue to proceed with the export. To view the Export Study Progress Window, click on the Background job indicator icon to the left of your username. If the export was a success, the notification simply disappears. If the export fails, the system will display a Failure message. The background job indicator will remain red and an ‘i’ symbol is available next to the failed job item. Importing Studies Importing Studies Audio Filename: sd_va40_workplace_importing-studies.mp3 Audio in Video: You can import studies to your syngo Dynamics workplace from external sources such as external hard drives, local drives, mapped network drives, CD/DVD and USB. Click on the Department/Server list and click on Select Folder at the top of the list. The Select Folder window opens, and the Refresh icon changes to a Folder icon. Browse to the folder containing the study or studies for import and select OK. The DICOMDIR window is displayed. Select to either Create New or Use Existing, for the DICOM directory. The study list shows the studies available for import. Select the appropriate studies. Within the Study menu, select Import Studies to the server name. To view the Import Study Progress Window, click on the Background job indicator icon to the left of your username. If the export is a success, the notification simply disappears. If any portion of the import fails, the progress window remains available, and a reason is provided for why the import failed. To clear the Import Study message, click on Cancel. A Confirmation request appears. Click Yes. The Import Study message disappears. Split Study now available in the Study Utilities menu Copy or Remove Protected Health Information (PHI) Split Study Split Study Audio Filename: sd_va40_workplace_splitting-studies.mp3 Audio in Video: Splitting studies is now available in the Study Utilities menu. Select the desired images by pressing control on your keyboard and clicking on the images. You can select all images by pressing control plus A on your keyboard. Alternatively, you can select all images by right click and selecting all images from the context menu. Click on Study Utilities, and then Split Study. Select the check mark to copy the Protected Heath Information (PHI) data from the source study if required. If the COPY PHI data from source study is checked, all PHI DICOM data is copied to the newly created study containing the images. If unchecked, you must manually enter mandatory values. Some of the PHI DICOM data in the DICOM header in the images will be blank. Select Split Study. syngo Dynamics displays a progress box indicating the number of images being retrieved, split, and finally stored. A message is displayed at the end indicating whether or not the split was successful. Refresh the Study List to display the new Split study. The images in the new study are not removed from the original study. If you want to delete them from the original study, select the images and select Delete Selected from the Context Menu. Please note, you must have the Privilege to delete images. Merge Study now available in the Study Utilities menu Progress Box indicates number of images being merged The study list order no longer applies Merge Study Merge Study Audio Filename: sd_va40_workplace_merging-studies.mp3 Audio in Video: To Merge two studies, select the studies from the study list that you would like to Merge. Select the studies in the order that you want to compare the studies. The study that you select first will appear on the left and is the primary study. The study that you select second will appear on the right. The images from this study will be merged with the study selected first. Select Study from the toolbar and select Compare. The two studies appear side by side. To Merge the studies, click on Study Utilities and select Merge Study. A dialog box appears, select OK to Merge. The study images on the right are merged to the left study. A progress box is displayed indicating the number of images being merged. A message box is displayed at the end indicating whether or not the merge was successful. The Study List is updated with the total number of merged images in the original study. Studies can be merged between any modalities, but each study must contain an image series. You cannot merge a study that is in collaborative mode, in progress, marked as read, or is locked. Please note that modifications made to stress echo images will not be retained when merged into another study. The merged images will revert to the original image sent from the modality. syngo Dynamics Remote Workplace syngo Dynamics Remote Workplace enables you to access syngo Dynamics remotely. Here, you view compressed* images (MP4) with the option to view original quality full DICOM images. Remote Workplace allows users to read and report in low bandwidth environments. In this chapter you will be introduced to the new syngo Dynamics Remote Workplace. *Compressed images are not intended for diagnostic use. syngo Dynamics Remote Workplace Images compressed in MP4 format Access to Original Quality Image Full reporting and measurement capabilities Remote Workplace Overview Remote Workplace Overview Audio Filename: sd_va40_workplace_remote-workplace-overview.mp3 Audio in Video: The default layout on the syngo Dynamics Remote Workplace, is 4:1. You can adjust the layout up to a maximum of 12:1 for compressed images. The selected layout is stored and applied on subsequent sessions. On the syngo Dynamics Remote Workplace, images are displayed compressed by default. The image compression is displayed in yellow at the bottom right of the image. Compressed images are in MP4 format and should not be used for diagnostic purposes. To view the original uncompressed DICOM image, click on the Original icon. The Remote Workplace has full reporting and measurement capabilities. Remote Workplace Limitations Although most functionality remains the same in both the syngo Dynamics Remote Workplace and the syngo Dynamics Workplace, there are some differences that you should be aware of. Some imaging functions are not possible with compressed images, but are available with original quality images, and some functionalities are not available. Click here to learn more. Remote Workplace Limitations Table with 2 columns and 1 rows Image Tools not available for compressed images: Edge enhancement and DSA mask Selecting a frame to be used as the mask frame Digital subtraction Adjusting window/level settings Features not available on syngo Dynamics Remote Workplace: Image Import/Export Study Split/Merge 3 rd Party Application launcher Remote Workplace Limitations Overview syngo Dynamics WebViewer The syngo Dynamics WebViewer application provides you with read-only access to compressed images* that can be accessed from any browser. The new WebViewer provides you with a common login screen and the same study list as the Workplace for a consistent user experience. In this chapter you will learn about the new syngo Dynamics WebViewer. *syngo Dynamics WebViewer is not intended for diagnostic use. syngo Dynamics WebViewer WebViewer Access You can access the WebViewer application using a standard internet browser through any desktop and mobile device, including your phone. Standard Web browser No license required Zero footprint Open/view patient studies Review images Reports can be viewed (PDF), but there is no reporting or worksheet functionality The content of the screen displayed depends on the available screen real estate. WebViewer Access WebViewer Image Review syngo Dynamics WebViewer is designed for viewing only and is not intended for diagnostic use. Images are compressed by a lossy method. You cannot perform any measurements or make any changes to images in the WebViewer. The images are displayed in a different tab in Internet Explorer. Each image is displayed in a separate image theater. WebViewer Image Review WebViewer Limitations syngo Dynamics WebViewer* is intended for viewing images and PDF reports on mobile devices. Therefore, there are some limitations in the syngo Dynamics WebViewer in comparison to the syngo Dynamics Workplace. No reporting or worksheet access (PDF of report is available) No corner menus or tools Cannot use mouse wheel to move frozen clip frame-by-frame, must use drag with “frame slider” 16:1, 20:1, n:1, and Split layouts are not available Cannot view original, full DICOM images, can only view additionally compressed images No biplane playback synchronization capability Cannot Export or Import studies Cannot view stress studies with phone or tablet, can only view on a desktop browser Can view key images, but cannot add or re-arrange key images 3rd Party Application Launcher (3PAL) not available Cannot assign studies to different departments If a study is orphaned in “Default” department, it will not be seen *syngo Dynamics WebViewer is not intended for diagnostic use. WebViewer Limitations Third-Party Applications Table with 3 columns and 1 rows GE EchoPAC v202.30 v203.49 MacLab (hemo) v6.5 v6.8 CardioLab (EP Prucka) v6.5 v6.8 Invia Corridor 4DM v2018 No additional mappings added beyond what was added with 4DM v2017 in syngo Dynamics version VA20G v2017 is no longer supported Merge Hemo 10.0.x (unchanged) Philips QLAB v11.0 v12.0 v13.0 Xper(hemo) N.A. CALYSTO Series IV (Witt) v7.96 v8.1 TomTec Arena v2.30.02 V2.3.1.0 Z Scores Boston Z Scores v17.1 PHN - version N.A. Siemens Sensis VC11D VC12M VIBE VD11B VIBE VD12A (VA40B) PIE Medical CAAS v8.2 (values are mapped via xml) Axis Clinicals Cath PCI v5.x IMPACT v2.0.1 Packages offered (unchanged): QCA (Quantitative Coronary Analysis) QCA3D (3D Quantitative Coronary Analysis) QVA (Quantitative Vascular Analysis) LVA (Left Ventricular Analysis) RVA (Right Ventricular Analysis) Third-Party Applications syngo Dynamics WebViewer syngo Dynamics Remote Workplace syngo Dynamics Workplace Course Review Congratulations. You have completed the syngo Dynamics VA40 Workplace Delta Online Training. Select the objectives listed below to review the material before proceeding to the final assessment. Additionally, a full course review is available in the Resources tab. 1 1 1 2 2 2 3 3 3 Course Review syngo Dynamics WebViewer syngo Dynamics WebViewer* is Read-Only and is not intended for diagnostic use. Reports can be viewed (PDF), but there is no reporting or worksheet functionality. You cannot view original, full DICOM images; you can only view additionally compressed images. 16:1, 20:1, n:1, and Split layouts are not available. No corner menus or tools. You cannot Export or Import studies. You cannot assign studies to different departments. *syngo Dynamics WebViewer is not intended for diagnostic use. syngo Dynamics Remote Workplace syngo Dynamics Remote Workplace enables you to access syngo Dynamics remotely. You can view compressed images* in MP4 format with the option to view original quality full DICOM images. Remote Workplace allows users to read and report in low bandwidth environments. The Remote Workplace has full reporting and measurement capabilities. The following functionality is not available in Remote Workplace: Image Import/Export Study Split/Merge 3rd Party Application launcher *Compressed images are not intended for diagnostic use. syngo Dynamics Workplace syngo Dynamics Workplace is the full-fledged application, displaying full DICOM images. Field Search has been replaced by Advanced Search. Customizing the study list columns can be done by utilizing the new Column Chooser functionality. When new studies are created, syngo Dynamics no longer creates a placeholder image for the study. Image related tasks have been moved to the Right-Click Context Menu. Split Study and Merge Study are now available within the Study Utilities menu. Using the n:1 layout, syngo Dynamics Workplace will now display as many images as can be rendered based on screen resolution. Moving the mouse to the right side of an image will display the Measurement Tools in the upper right corner. Moving the mouse to the bottom of an image will display the Image Tools in the lower right corner. Tooltips provide details about each tool in corner menus. Right-Clicking an image will open the context menu. Left-Click to start and stop video clips. The mouse wheel can be used to navigate a clip frame-by-frame. To avoid inadvertently selecting images, you must now use Ctrl + Left-Click to select or deselect images. Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters / Siemens Healthcare GmbH / Henkestr. 127 / 91052 Erlangen, Germany Telephone: +49 9131 84-0 / www.siemens-healthineers.com Disclaimer Disclaimer Assessment This assessment will test your retention of the presented content. A passing score of 80% or higher is required to complete the course and earn your certificate. You may repeat the assessment as many times as needed. Start Assessment Which application is the full-fledged application, displaying full DICOM images and doesn’t require an Original Quality Viewer? Question 1 of 5 Select the applicable image. Workplace Remote Workplace WebViewer Question 1 Incorrect The WebViewer application gives you read-only access to compressed images. Incorrect The Remote Workplace allows you to view compressed images (MP4) with the option to view original quality full DICOM images. Correct Export Images Context Menu Split Studies Worksheet Right-Clicking an image opens which of the following? Question 2 of 5 Select the best answer. Question 2 Incorrect Worksheets are launched by clicking the Worksheet Icon in the main menu. Incorrect Splitting studies is available within the Study Utilities menu. Incorrect Correct Exporting images is available through the Study menu. Ctrl + Left-Click Space Bar Ctrl + Alt + Del Right-Click To avoid inadvertently selecting images, you must now use which keys to select or deselect images? Question 3 of 5 Select the best answer. Question 3 Incorrect Right-Clicking an image will launch the Context menu. Incorrect Ctrl+Alt+Del is a Windows command. Incorrect The Space Bar will Stop and Start a video clip. Correct Opens the Context Menu Opens the Measurement Tools Start and Stop the video Launch third-party applications Left-Clicking a video clip will do which of the following? Question 4 of 5 Select the best answer. Question 4 Incorrect Third-part applications are launched from the Utilities Menu. Incorrect Incorrect The Measurement Tools are available by moving the mouse to the right of an image. Correct The Context menu is opened by Right-Clicking an image. Context Menu Measurement Tools Exporting and Importing studies Which of the following functionalities is not available in the Remote Workplace application? Question 5 of 5 Select the best answer. Question 5 Incorrect Incorrect The Image and Measurement tools are available in the Remote Workplace application. Correct The Right-Click Context menu is available in the Remote Workplace application. Review Review Retry Assessment Results %Results2.ScorePercent%% %Results2.PassPercent%% Continue YOUR SCORE: PASSING SCORE: Assessment Results You did not pass the course. Take time to review the assessment then select Retry to continue. Congratulations. You passed the course. Exit To access your Certificate of Completion, select the Launch button drop down on the course overview page. You can also access the certificate from your PEPconnect transcript. You have completed the syngo Dynamics VA40 Workplace Delta Online Training. Completion HOOD05162003098149 | Effective Date: 10-JUN-2020 Course Review 1.1 Welcome 1.2 syngo Dynamics New Features and Improvements 1.3 User Interface Design 1.4 Common Study List Redesign 1.5 Advanced Search 1.6 Column Chooser 1.7 Study List File Menus 1.8 New (n:1) Layout 1.9 Thumbnails 1.10 Right-Click Context Menu & Study Utilities 1.11 Corner Menus 1.12 Zoom and Pan 1.13 Calc Palette 1.14 Image Navigation (Mouse Functions) 1.15 Key Images (Method 1) 1.16 Key Images (Method 2) 1.17 syngo Dynamics Workplace 1.18 Exporting Studies 1.19 Importing Studies 1.20 Split Study 1.21 Merge Study 1.22 syngo Dynamics Remote Workplace 1.23 Remote Workplace Overview 1.24 Remote Workplace Limitations 1.25 syngo Dynamics WebViewer 1.26 WebViewer Access 1.27 WebViewer Image Review 1.28 WebViewer Limitations 1.29 Third-Party Applications 1.30 Course Review 1.31 Disclaimer 1.32 Assessment 1.39 Completion
- workplace
- syngo dynamics