syngo Dynamics -Create or Edit a Phrase
syngo Dynamics -Create or Edit a Phrase
syngo Dynamics Report Designer Step-by-step Step 2: Create/Edit a Phrase 1. Open Phrase Editor in Report Designer. Libraries>Phrase Library. File Edit View Libraries Tools Help Arial Measurement and Calculation Library Physician Observation Library LV EF (Mmode): Phrase Library LV SYSTOLIC F Indications and Diagnosis Library EF-A4C View: 76.1 Definition Editor D: Wall Scoring Scores Library -Biplane LV DIASTOLIC FUN Wall Scoring Report Generation Library MW Doak F. 3 75 mle lacal lima 627 mear DTIDV A V 2. As in the Observation Library, on the left the Calc Type and Language can be selected. Below that are the categories for the phrases as well as a Find field to narrow Phrase searches. New Phrases and New Categories are added from here as well. Phrase Library Editor - C:\Users\Z00309HE\DesktopsD Desktop\Adult_Echo_Bundle Adult Echo Bundle File Edit Phrases Phrase Definition Calc Type: Cardiac Name Category 2D Language English (Unite I Worksheet Phrase Body + 2D + Aorta Aorta-ASE AOV + AoV-ASE Appropriate Use Criteria + ASD Separator Last separator and Insert Data + Atria AUC + AV Connections Include phrase in report body if ... AVSD Norma Not well visualized O Abnormal D Other BWH Comments Auto capitalize and auto punctuate Comparison Contrast -Summary Coronary Arteries ECG .... Fetal Great Vessels IAS + IVC/HV-ASE LA Insert Data .... + LA-ASE + LV .... + LVAD Include phrase in report summary if ... O Normal I Not well visualized I Abnormal Other Find: New Phrase I Auto capitalize and auto punctuate New Category Hide www.usa.siemens.com/healthcare SIEMENS 745 Effective date 9/8/2016 Page 1 of 5 Phrase Library Editor - C:\Users\Z003C9HE\Desktop\sD Desktop\Adult_Echo_Bundle\Adult Echo Bundle O X File Edit Phrases Phrase Definition Calc Type: Cardiac Name Category 20 Language English (Unite Worksheet Phrase Body 2D o Aorta @ Aorta-ASE O. AoV O. AOV-ASE Appropriate Use Criteria O. ASD Separator, Last separator and Insert Data o Atria O AUC AV Connections Include phrase in report body if ... O AVSD 0 Normal D Not well visualized [ Abnormal Dothe BWH Comments [] Auto capitalize and auto punctuate Comparison Contrast Summary Coronary Arteries ECG Fetal Great Vessels IAS # IVC/HV-ASE @ LA Insert Data @ LA-ASE LV LVAD Include phrase in report summary if ... Find: I Normal [] Not well visualized [ Abnormal Dothe New Phrase [] Auto capitalize and auto punctuate New Category Hide 3. The left box shows that MR degree has been selected in the Category of MV. The center box represents both the selected observation (in green and in between greater than and less than signs) and the Phrase for the body of the report. The Insert Data button (right box) opens a window to select the desired observation to put in the Phrase. Phrase Library Editor - C:\Users\Z003C9HE\Desktop\sD Desktop\Adult_Echo_Bundle\Adult Echo Bundle File Edit Phrases Phrase Definition Calc Type: Cardiac Name MR degree Category MV Language English (Unite Worksheet Phrase Body- MV mitral regurgitation is present. Absent A wave ERO-PISA Mitral Stenosis - mean MR degree MR_Regurgitant Fraction MR_Regurgitant Volume Separator Last separator Insert Data MR_Vena contracta MS and MV descript MV annular repair Include phrase in report body if ... MV appearance MV Area P1/2 t ] Normal Not well visualized ] Abnormal Other MV chordae [Y] Auto capitalize and auto punctuate MV cleft MV Comments Summary MV flail leaflet [ mitral regurgitation MV mean grad MV mechanical type MV noncoaptation MV Normal MV Normal To Summary MV NWV Insert Data MV orifice size - congenit MV Pap muscle config Include phrase in report summary if ... Find : O Normal I Not well visualized 2 Abnormal Other New Phrase M Auto capitalize and auto punctuate New Category Hide SIEMENS www.usa.siemens.com/healthcare Page 2 of 5 4. After selecting Insert Data, the following window will open. In this sample, the Observation tab is selected. MR degree has been searched for returning 2 possible choices. This is the Observation that will enter data into the Phrase. Data Palette Contexts Patient |Calcs Observations -- MV MR degree MR degree 0 OK mr degree Cancel 5. The Body field on top shows the content for the body of the Report. The Summary field on the bottom represents the content for the Summary. Notice the checkboxes below the sentences. In the Body of the Report, the Phase will be inserted if the Observations were designated Normal, Abnormal or Other. For the Summary, the Phrase will only display if the associated Observation was designated as Abnormal. (See Step 1 to assign these to an Observation). Body I Worksheet Phrase mitral regurgitation is present. Separator Last separator Insert Data Include phrase in report body if ... ] Normal [ Not well visualized ] Abnormal Other [] Auto capitalize and auto punctuate Summary mitral regurgitation Insert Data Include phrase in report summary if ... O Normal [ Not well visualized ] Abnormal D Other M Aute capitalize and auto punctuate www.usa.siemens.com/healthcare SIEMENS Page 3 of 5 6. In the following sample, two Observations have been added to one Phrase. In this setting both Observations must be selected on the Worksheet to generate the phrase for the report. Note that this Phrase will appear in the Body of the Report since all 4 boxes below the Phrase are checked. For the Summary, no Phrase will go in the Report since there is no content and no boxes are selected. Also note Auto capitalize and auto punctuate is checked. This selection means the first letter of a Phrase will be capitalized and a period will follow each Phrase. Body The thrombus measures approximately mm by mm. Separator Last separator Insert Data Include phrase in report body if ... M Normal ] Not well visualized Abnormal Other [] Auto capitalize and auto punctuate Summary Insert Data Include phrase in report summary if ... Normal I Not well visualized Abnormal D Other 7. More advanced features are available including using ‘is’ and ‘are’ for singular versus pleural and using [ ] (brackets) to exclude observations. See Advanced Template Customization in Report Designer User Manual for Advanced options. 8. At the end it is important to save your work. It is recommended to be in the habit of the following save options below after ALL work. Work can never be over-saved!! File Edit View Libraries Tools Help Times New Romar + 24 BIU 3 6 Physician Save All Save All Libraries Heart Health Medical syngo Conton 9. Save All Libraries and Save All. You can also Save all work at the end of this step by selecting File>Save All File Edit View Libraries Tools Help New Open Close Save Worksheet Save Worksheet As ... Save Report "sD Adult Echo.kit" Save Report "sD Adult Echo.krt" As ... Save All Load Previously Saved Report Load Previously Saved Worksheet Preferences Print Preview Print Worksheet Properties Report Properties Exit www.usa.siemens.com/healthcare SIEMENS Page 4 of 5 On account of certain regional limitations of Local Contact Information sales rights and service availability, we cannot guarantee that all products included in this Siemens Medical Solutions USA, Inc. brochure are available through the Siemens 51 Valley Stream Parkway sales organization worldwide. Availability and Malvern, PA 19355-1406 packaging may vary by country and is subject USA to change without prior notice. Some/All of the Phone: +1-888-826-9702 features and products described herein may not www.usa.siemens.com/healthcare be available in the United States. The information in this document contains Global Business Unit general technical descriptions of specifications and options as well as standard and optional Siemens AG features which do not always have to be present Medical Solutions in individual cases. X-ray Products Henkestr. 127 Siemens reserves the right to modify the design, DE-91052 Erlangen packaging, specifications and options described Germany herein without prior notice. Please contact your Phone: +49 9131 84-4746 local Siemens sales representative for the most www.siemens.com/healthcare current information. Note: Any technical data contained in this document may vary within defined tolerances. Original images always lose a certain amount of detail when reproduced. Global Siemens Headquarters Global Siemens Legal Manufacturer Healthcare Headquarters Siemens AG Siemens AG Wittelsbacherplatz 2 Siemens AG Wittelsbacherplatz 2 80333 Muenchen Healthcare Sector DE-80333 Muenchen Germany Henkestrasse 127 Germany 91052 Erlangen Germany Phone: +49 9131 84-0 www.siemens.com/healthcare www.siemens.com/healthcare 36 | All rights reserved | © 2014 Siemens Medical Solutions USA, Inc.
- syngo X Workplace