syngo Dynamics: How to Merge Studies
How to Merge Studies in syngo®Dynamics You must have the Split/Merge Privilege to be able to merge studies. 1. To merge studies: After Login to syngo® Dynamics Select the server from the Studies From: drop-down menu. [You can only merge studies that are currently online on the server, and in the same Department.] Sort the Study List so that the study receiving the images (Primary Study) appears before the study donating images (Secondary study). Select the two studies by clicking once on each to highlight both. The first study in the list is displayed as the Primary Study. Patient Study Utilities Print SUSAS VAL Dept: AdultEcho Quick Search studies From: AdultEcho studies in list: 177 Selected: 2 Name Starts With ... Patient ID Is ... Search : All Unread Patient Name + Patient ID Date Of Birth Accession # Diagnosing Physician # of Images Report Status Study Type Study Date Study Status Study Location Referring Phy ... Diagn Zeuss, Harold 9817281534 3/4/1939 DATA_MINING_816 Adult Heart 4/27/2015 10:28:16 AM Unread Online Zeuss, Harold 9817281534 3/4/1939 DATA_MINING_835 Adult Heart 4/27/2015 10:28:35 AM Unread Online Yaseem, Helutia 57671721 8/2/1934 DATA_MINING_815 Adult Heart 4/27/2015 10:28:15 AM Unread Online Yaseem, Helutia 57671721 8/2/1934 DATA_MINING_842 Adult Heart 4/27/2015 10:28:42 AM Unread Online Wells, Nick 0182817 5/1/1957 DATA_MINING_846 Adult Heart 4/27/2015 10:28:46 AM Unread Unread Online Wells, Nick 0182817 5/1/1957 DATA_MINING_857 Adult Heart 4/27/2015 10:28:57 AM Unread Online Wells, Nick 0182817 5/1/1957 DATA MINING_829 Adult Heart 4/27/2015 10:28:29 AM Unread Wangen, Dniel 815S 9/28/1973 DATA_MINING_353 Adult Heart 12/28/2015 10:23:53 AM Unread Online Keehner, Maric Vicente, David 25/1963 DATA_MINING_353 12/17/2015 10:23:40 AM Unread Online Kechner, Mark Verdenas, Harold (1/1952 DATA_MINING_812 Adult Heart 27/2015 10:28:12 AM Unread Online Verdenas, Harold Primarystudy (1/1952 DATA_MINING_845 Secondary study 27/2015 10:28:45 AM Unread Online Venutis, Byron 1/15/1946 DATA_MINING_646 Adult Heart 27/2015 10:28:46 AM Unread Venutis, Byron 981712 11/15/1946 DATA_MINING_838 27/2015 10:28:38 AM Unread Online Valgardson, Rory 175248756 10/10/1955 SC2000 CONTRAST Pharm Stress 11/4/2009 2:32:52 PM Unread Online Urdeta, Jamie 7671817 2/14/1982 DATA_MINING_819 Adult Heart 4/27/2015 10:28:19 AM Unread Online Urbettens, Glinda 2365412 9/18/1959 DATA_MINING_853 Adult Heart 4/27/2015 10:28:53 AM Unread Online Tumar, Sean 7398291 2/9/1957 DATA_MINING_823 Adult Heart 4/27/2015 10:28:23 AM Unread Tumar, Sean 7398291 2/9/1957 DATA_MINING_843 Adult Heart 4/27/2015 10:28:43 AM Unread Online Tisdale, Leanna 43075 6/27/1954 DATA_MINING_353 Adult Heart 12/8/2015 10:23:28 AM Unread Online Keehner, Maric Thip, Margaret 341425 2/9/1954 DATA_MINING_833 Adult Heart 4/27/2015 10:28:33 AM Unread Online Thip, Margaret 341425 2/9/1954 DATA_MINING_830 Adult Heart 4/27/2015 10:28:30 AM Unread Online Thip, Margaret 341425 2/9/1954 DATA_MINING_829 Adult Heart 4/27/2015 10:28:29 AM Unread Thankners, Robert 2126612215435 6/24/1927 DATA_MINING_837 Adult Heart 4/27/2015 10:28:37 AM Unread Online Thandos, Mark 5147617345 2/9/1979 DATA_MINING_827 Adult Heart 4/27/2015 10:28:27 AM Unread Online Tedrow, Cher 064829067 11/7/1956 SC2000 CONTRAST Cardiologist Stress Echo Exen 10/28/2009 1:14:52 PM Unread Online Tedrow, Cher 064829067 11/7/1956 ACUSON ECHO Cardiologist Stress Echo Phan 2/25/2005 8:30:17 AM Unread Online Taylor, Rafael 20117 10/8/1927 DATA_MINING_353 Adult Heart 12/2/2015 10:23:22 AM Unread Online Kechner, Mark Summa, Dong 83288 12/9/1945 DATA_MINING_353 Adult Heart 11/28/2015 10:23:27 AM Unread Online Kechner, Markc Stubbs, Angela 75433 5/9/1949 DATA_MINING_353 Adult Heart 11/25/2015 10:23:38 AM Unread Online Kechner, Markc Storms, Cathi 9114 3/13/1952 DATA_MINING_353 Adult Heart 11/24/2015 10:23:46 AM Unread Online Keehner, Mark Still, Jorge 16877 2/23/1939 DATA_MINING_353 Adult Heart 11/22/2015 10:23:29 AM Unread Online Kechner, Maric Stack, Regis 73481 1/28/1919 DATA_MINING_353 Adult Heart 11/19/2015 10:23:17 AM Unread Keehner, Maric Sommerville, Grant 86407 7/24/1911 DATA_MINING_353 Adult Heart 11/14/2015 10:23:42 AM Unread online Keehner, Maric Crschaminh Malinits 8/1/2017 1-15:26 DM linrosà Copy Studies To ... Assign Studies To ... SIEMENS siemens.com/healthineers Healthineers Job Aid | syngo® Dynamics Effective Date: 01/09/2018 | Quality HOOD5162002748248 2. Select Compare Studies from the Study menu to display the images of both studies. Study Utilities Print Help Mark Study as Read SUSAS VOL. Dept Mark Study as Unread Quick Search From: Mark all reports for selected studies as completed Nome Starts With ... Patient ID Is ... Search: All Unread Mark all reports for selected studies as verified Diagnosing Physician of Images Report Status Study Type Study Date Study Status Study Location Referring Phy- Diagnosit Merge Studies 35 D Adult Heart 4/27/2015 10:28:35 AM Unread Online Split Study 16 D Adult Heart 4/27/2015-10:28:16 AM Unread Online 42 D Adult Heart 4/27/2015 10:28:42 AM Unread Online Create New Study ... 15 D Adult Heart 4/27/2015 10:28:15 AM Unread Online Carry Data Forward From Previous Study 29 D Adult Heart 4/27/2015 10:28:29 AM Unread Online 57 D 4/27/2015 10:28:57 AM Unread Online Reset Grid Changes 46 D Adult Heart 4/27/2015 10:28:46 AM Unread Online 53 Compare Studies D Adult Heart 12/28/2015 10:23:53 AM Unread Online Keehner, Mark 53 D Adult Heart 12/17/2015 10:23:40 AM Unread Online Keehner, Mark Select All Studies 145 D Adult Heart 4/27/2015 10:28:45 AM Unread Online 112 D Adult Heart 4/27/2015 10:28:12 AM Unread Online Deselect All Studies ------ 138 D Adult Heart 4/27/2015 10:28:38 AM Unread Online Set Recompression ... 146 D Adult Heart 4/27/2015 10:28:46 AM Unread Online ST D Pharm Stress 11/4/2009 2:32:52 PM Unread Online Open and Cache Study with Recompression 6TI D Adult Heart 4/27/2015 10:28:19 AM Unread Online Save Study List to File ... 53 D Adult Heart 4/27/2015 10:28:53 AM Unread Online 143 -- - D Adult Heart 4/27/2015 10:28:43 AM Unread Online Refresh Study List D Adult Heart 4/27/2015 10:28:23 AM Unread Online Assign Study to Dept 53 D Adult Heart 12/8/2015 10:23:28 AM Unread online Kechner, Mark 29 D Adult Heart 4/27/2015 10:28:29 AM Unread Online Transfer Reports OE D adult Hea 4/27/2015 10:28:30 AM Unread Online Export Data for Selected Studies EE D Adult Heart 4/27/2015 10:28:33 AM Unread Online 137 D Adult Heart 4/27/2015 10:28:37 AM Unread Online Import Hemodynamic/Sensis EP Data - - 27 D Adult Heart 4/27/2015 10:28:27 AM Unread Online Import Electrophysiology Data Cardiologist 18 D Stress Echo Pharm 2/25/2005 8:30:17 AM Unread Online ST Cardiologist 23 D Stress Echo Exercise 10/28/2009 1:14:52 PM Unread Online Send Study to DICOM Node 53 1 D Adult Heart 12/2/2015 10:23:22 AM Unread Online Keehner, Mark Delete Selected Studies 53 D Adult Heart 11/28/2015 10:23:27 AM Unread Online Keehner, Mark 53 --- D Adult Heart 11/25/2015 10:23:38 AM Unread Online Keehner, Maric Remove Local Copies 53 D Adult Heart 11/24/2015 10:23:46 AM Unread Online Keehner, Mark Still, Jorge 16877 2/23/1939 DATA_MINING_353 D Adult Heart 11/22/2015 10:23:29 AM Unread Online Kechner, Maric Stack, Regis 73481 1/28/1919 DATA_MINING_353 D Adult Heart 11/19/2015 10:23:17 AM Unread Online Keehner, Maric Sommerville, Grant 7/24/1911 DATA_MINING_353 D Adult Heart 11/14/2015 10:23:42 AM Unread Online Kechner, Maric vimos Copy Studies To ... Assign Studies To ... 3. The Primary study (image receiver) will be displayed on the left and the Secondary study (image donor) will be displayed on the right. Patient Study Utilities Images Print Help Zeuss, Harold 4/27/2015 Zeuss, Harold 4/27/2015 9817281534 10:28:16 AM vert 9817281534 10:28:35 AM 3/4/1939 (M) Adult Heart Report Close 2/4/1939 (M) Adult Heart syngo Dynamics syngo Dynamics Receiving Study De Bater 8/31/2013 Primary Study Secondary Study Siemens Healthineers Services Page 2 of 5 Job Aid | syngo® Dynamics Effective Date: 01/09/2018 | Quality HOOD5162002748248 4. From the Study menu, select Merge Studies. Patien Study Utilities Images Print Help Zeuss, Harold Mark Study as Read Report 9817281534 16:28:35 AM Worksheet Tools Close 3/4/1939 (M) Adult Heart 1 to 1 of 1 12 : 1 Mark Study as Unread SIEMENS Mark Current Report as Completed Mark Current Report as Verified Merge Studies syngo Dynamics Split Study Create New Study ... Carry Data Forward From Previous Study Reset Grid Changes Compare Studies mage Time-3:34 40 PM Select All Studies Deselect All Studies S Set Recompression ... Open and Cache Study with Recompression Save Study List to File ... Refresh Study List Assign Study to Dept Transfer Reports Export Data for Selected Studies Import Hemodynamic/Sensis EP Data Import Electrophysiology Data Send Study to DICOM Node Delete Selected Studies Remove Local Copies 5. A dialogue box will appear to confirm the study merge. Click OK to Merge button to confirm the merge and continue. Or, click Do Not Merge button to cancel the merge. Study Utilities Image Zeuss, Harold 4/27/2015 Zeuss, Harold 3/27/2015 9817281534 9817281534 3/4/1939 (M) Tools Close 3/4/1939 (M) Adult Heart" 1 to 1 of 1 SIEMENS SIEMENS syngo Dynamics syngo Dynamics Receiving Study Merge Confirmation Required X Image Time:3:34:40 PM mage Date: 5/31/2013 A JPEG Lessy 12:1 The right hand study images are appended to the left hand study. OK To Merge Do Not Merge e Siemens Healthineers Services Page 3 of 5 Job Aid | syngo® Dynamics Effective Date: 01/09/2018 | Quality HOOD5162002748248 6. In the Study List the Primary Study will have the selected images appended at the end of the image set. Both studies will remain on the server. You can delete the Secondary study from the Study List if you wish, and have the appropriate privileges. Patient Study Utilities Print Help SUSAS Val .. AdultEcho Quick Search AdultEcho selected: 1 1 Name Starts With ... Patient ID Is ... Search: All Unread Patient ID Date of Birth Accession Diagnosing Physician or Images Report Status study type Study Date Study Status |Study Location |kererring Phy ... Diagn Zeuss, Harold 9817281534 3/4/1939 DATA_MINING_835 1 D Adult Heart 4/27/2015 10:28:35 AM Unread Online Zeuss, Harold 9817281534 3/4/1939 DATA_MINING_816 2 D Adult Heart 4/27/2015 10:28:16 AM Unread Online Yaseem, Helutia 57671721 8/2/1934 DATA MINING_842 D Adult Heart 4/27/2015 10:28:42 AM Unread Online Yaseem, Helutia 57671721 8/2/1934 DATA_MINING_815 D Adult Heart 4/27/2015 10:28:15 AM Unread Online Wells, Nick 0182817 5/1/1957 DATA_MINING_829 D Adult Heart 4/27/2015 10:28:29 AM Unread Online Wells, Nick 0182817 5/1/1957 DATA_MINING_857 D Adult Heart 4/27/2015 10:28:57 AM Unread Online Wells, Nick 0182817 5/1/1957 DATA_MINING_846 D Adult Heart 4/27/2015 10:28:46 AM Unread Online Wangen, Dniel 8155 9/28/1973 DATA_MINING_353 D Adult Heart 12/28/2015 10:23:53 AM Unread Online Keehner, Maric ---------- Vicente, David 56140 7/25/1963 DATA_MINING_353 D Adult Heart 12/17/2015 10:23:40 AM Unread Online 1594519 Keehner, Maric Verdenas, Harold 1526519 6/1/1952 DATA_MINING_845 D Adult Heart 4/27/2015 10:28:45 AM Unread Online Verdenas, Harold 1526519 6/1/1952 DATA_MINING_812 D Adult Heart 4/27/2015 10:28:12 AM Unread Online Venutis, Byron 981712 11/15/1946 DATA_MINING_838 D Adult Heart 4/27/2015 10:28:38 AM Unread Online Venutis, Byron 981712 11/15/1946 DATA_MINING_846 D Adult Heart 4/27/2015 10:28:46 AM Unread Online Valgardson, Rory 175248756 10/10/1955 SC2000 CONTRAST D Pharm Stress 11/4/2009 2:32:52 PM Unread Online Urdeta, Jamie 7671817 2/14/1982 DATA_MINING_819 1 D Adult Heart 4/27/2015 10:28:19 AM Unread Online Urbettens, Glinda 2365412 9/18/1959 DATA_MINING_853 D Adult Heart 4/27/2015 10:28:53 AM Unread Online Tumar, Sean 7398291 2/9/1957 DATA_MINING_843 D Adult Heart 4/27/2015 10:28:43 AM Unread Online Tumar, Sean 7398291 2/9/1957 DATA_MINING_823 D Adult Heart 4/27/2015 10:28:23 AM Unread Online Tisdale, Leanna 43075 6/27/1954 DATA_MINING_353 D Adult Heart 12/8/2015 10:23:28 AM Unread Online Keehner, Maric ------ Thip, Margaret 341425 2/9/1954 DATA_MINING_829 D Adult Heart 4/27/2015 10:28:29 AM Unread Online Thip, Margaret 341425 2/9/1954 DATA_MINING_830 D Adult Heart 4/27/2015 10:28:30 AM Unread Online Thip, Margaret 341425 2/9/1954 DATA_MINING_833 D Adult Heart 4/27/2015 10:28:33 AM Unread Online Thankners, Robert 2126612215435 6/24/1927 DATA_MINING_837 D Adult Heart 4/27/2015 10:28:37 AM Unread Online Thandos, Mark 5147617345 2/9/1979 DATA_MINING_827 D Adult Heart 4/27/2015 10:28:27 AM Unread Online Tedrow, Cher 064829067 11/7/1956 ACUSON ECHO Cardiologis 18 D Stress Echo Phan 2/25/2005 8:30:17 AM Unread Online Tedrow, Cher 064829067 11/7/1956 SC2000 CONTRAST Cardiologist 23 D Stress Echo Exen 10/28/2009 1:14:52 PM Unread Online Taylor, Rafael 20117 10/8/1927 DATA_MINING_353 1 D Adult Heart 12/2/2015 10:23:22 AM Unread Online Keehner, Maric Summa, Dong 83288 12/9/1945 DATA_MINING_353 D Adult Heart 11/28/2015 10:23:27 AM Unread Online Keehner, Maric Stubbs, Angela 75433 5/9/1949 DATA_MINING_353 D Adult Heart 11/25/2015 10:23:38 AM Unread Online Keehner, Maric Storms, Cathi 9114 3/13/1952 DATA_MINING_353 D Adult Heart 11/24/2015 10:23:46 AM Unread Online Keehner, Maric Still, Jorge 16877 2/23/1939 DATA_MINING_353 D Adult Heart 11/22/2015 10:23:29 AM Unread Online Keehner, Maric Stack, Regis 73481 1/28/1919 DATA_MINING_353 D Adult Heart 11/19/2015 10:23:17 AM Online Keehner, Maric Sommerville, Grant 86407 DATA_MINING_353 D Adult Heart 11/14/2015 10:23:42 AM Unread Online Keehner, Maric Crarharmich Malinds Adult Crhn Anlina Copy Studies To ... ssign Studies To ... Siemens Healthineers Services Page 4 of 5 Job Aid | syngo® Dynamics Effective Date: 01/09/2018 | Quality HOOD5162002748248 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright @ Siemens Healthcare GmbH Siemens Healthineers Headquarters Siemens Medical Solutions USA, Inc Siemens Healthcare GmbH 40 Liberty Boulevard Henkestr. 127 Malvern, PA, 19355, USA 91052 Erlangen, Germany Phone: Telephone: +49 9131 84-0 +1-610-448-4500 / +1-888-826-9702 siemens.com/Healthineers siemens.com/syngo Siemens Healthineers Services Page 5 of 5
- syngo
- dynamics
- how to merge
- studies