syngo Dynamics-Add Observation to Worksheet
syngo Dynamics-Add Observation to Worksheet
syngo Dynamics Report Designer Step-by-step Step 3: Add Observation to Worksheet 1. The Worksheet is the right side of the Report Designer interface. It is laid out to look like the Worksheet where the user enters data. file://C:\Users\200JC9HE\Desktop\sD Desktop\Adult_Echo_Bundle\Adult Echo BundlesD Adult Echo Expanded kwt File Edit View Libraries Tools Help Arial 10 Physician B XED A&A Echo Expanded kwf Graphic Echo Medical Center Pt AUC 2D Dop LV LV2 Peri RA RV LA MV TV AOV Ao PV/PA Veins Shunt not Found 123 Easy Template Way. Yourtown, USA 99999 cet normal. LV Commerce)) Phone: (800) 888-7436 Fax: (800) 123-4967 NORMAL LV []Send to summary -- > Comparison to Prior Study LV NWV [] Definity contrast used LV Measurements & Calculations TRANSTHORACIC ECHOCARDIOGRAM REPORT EF by Visual Estimation Send EF to summary Patient Name: John Doe Date of Exam: 1/1/2007 Septal Thickness Global LV systolic function Medical Roc #: A33578.1023872768 Custom1: < ... om Field 15 < ... her Pt. ID> Custom2. < ... om Field 2> O normal O normal O sev decreased Account # Date of Birth: 1/1/1920 Height 65 0 in O midy increased O mild decreased O hyperdynamic Patient Age: 87 years Weight: 125.0 lb O moderately increased O mild to mod decr O hypokinetic Patient Gender F BSA 1.62 m* O severely increased O mod decreased O decreased O mod to sev decr Indications < ,ndications> O disproportionate LV Internal Dimension Sonographer. Jameson O normal O mod to sev increased Referring Phys; Marcus Bonnae Report CC'd to: James Smith, Stephen G VPW O mildly increased O severely increased Cm O normal O mild to mod increased O decreased Sonographer Comments: O mildy increased O moderately increased Cardiomyopathy Appropriate Use Criteria: O moderately increased O severely increased O ischemic O global O constrictive 20 AND M-MODE MEASUREMENTS (normal ranges within parentheses): O decreased O hypertensive O restrictive Left Ventricle: Normal Aorta/Left Atrium: Normal O disproportionate O ichopathic O dilated O Spongioform IV96 (20) 1.07 cm (0 7-1.1) Aortic Root (Mmode) 3.22 cm (2 4-3.7) O post partum O infiltr ative LVPWd (20); 1.09 cm LVIDd (2D) (0.7-1.1) AoV Cusp Separation: 0.60 cm (1.5-2.6) Left Ventricular Hypertrophy 6.00 cm (3.4-5.7) Left Atrium (Mmode): 4.88 cm (1.9-4.0) LVIDS (20) 5.51 cm LVH degrea LVH type LVH location (optional) LV FS (2D) 8.2 % (>25%) LA Volume A/.: O no O evidence of all posterior LV EF (20) 17.9 % (>50%) LA Val AIC A/L 51.6 ml O borderline O concentric IVSd (Mmode). 1.26 cm (0.7-1.1) LA Vol A2C A/L 51.6 ml O mild O asymmetric anterior 0 lateral LVPWd (Mmode): 0.82 cm LVIDd (Mmode): (0.7-1 1) LA Vol BP A/L 51.6 ml (3.4-5.7) O moderate 0 basal [] apical 6.60 cm O eccentric LVIDs (Mmode). 5.92 cm Right Ventriclei O severe O septal 0 septal LV FS (Mmode) 10.2 % (>25%) RVd (20) 1,72 cm LV EF (Mmode) 21.8 % (50%) LV Diastology This step by step will review placing an Observation on the Worksheet. For more detailed Worksheet functionality, See Report Designer User Manual. 2. The green bar at the top of the Worksheet indicates the Worksheet is active and can be worked on. Clicking anywhere on the Worksheet will highlight this bar. X SD Adult Echo Expanded.kwt Pt AUC 2D Dop LV LV2 Peri RA RV LA MV TV AOV Ao PV/PA Veins Shunts set normal ) ( LV Comments 3. The icon that looks like notebook paper opens the Data Palate window. i file://C:\Users\Z003C9HE\Desktop\sD Desktop\Adult_Echo_Bundle\Adult Echo Bundle\sD Adult Ech File Edit View Libraries Tools Help Arial ¥ 10 B SIEMENS www.usa.siemens.com/healthcare 746 Effective date 9/8/2016 Page 1 of 6 4. In the Data Palate window, information housed in various libraries and in the data base can be placed on the Worksheet. Below, the tabs are highlighted. For this exercise, an Observation will be used but other tabs house patient information, measurements and calculations, phrases and layout features. Worksheet Data Palette Patient |Calcs Observations Phrases |Layout + .. 2D +- 2D Dimensions - Aorta #- Aorta-ASE #- AOV E #- AoV-ASE @- Appropriate Use Criteria + ASD +- Atria #- AV Connections +- AVSD #. Comments ... Comparison #- Contrast @. Coronary Arteries 4- EKG #- Great Vessels + IAS +- IVC/HV-ASE .- LA @- LA-ASE ··· LV +- LVAD A. I V-ASF Find: Calc Type Cardiac Item: Context: Properties Short Title LV Title LV Add Tab, Remove Tab Title The section's title. www.usa.siemens.com/healthcare SIEMENS Page 2 of 6 5. The Observations are separated into the same categories that are seen in the Observation Library. The find window can help narrow a search with key words. Worksheet Data Palette Patient |Calcs Observations Phrases |Layout +- 2D +- 2D Dimensions Aorta Aorta-ASE + ·· AoV AOV-ASE .... · Appropriate Use Critelia .... .... Atria AV Connections + ·· AVSD ..... + ..... Comments + Comparison .... +. Contrast .... +. Coronary Arteries + EKG Great Vessels +- IAS .... IVC/HV-ASE .... " ·· LA ... LA-ASE H- LV +. LVAD + ·· IV-ASF Find: Calc Type Cardiac 6. Once the Observation has been highlighted (left image), it can be left clicked and dragged onto the Worksheet. Note the Observation defaults to a collapsed state (right image). Right clicking opens a window allowing you to expand the Observation (bottom image) and change the display name if desired. - Pericardium --. Pericardium-ASE +- Pleural Space Practice Car Color #- Prior Interventions Car Color Show Expanded #. Prosthetic Valves Definition Display Name: Car Color ... Pulmonary Veins # .. Pulmonary Veins-ASE DV Car Color O red O green O blue O white O black O silver O yellow www.usa.siemens.com/healthcare SIEMENS Page 3 of 6 7. The bottom of the Data Palate displays the properties of the Observation on the Worksheet. Worksheet Data Palette 6 6 X Patient |Calcs Observations Phrases Layout PDA Pericardium X SD Adult Echo Expanded kwt Pericardium-ASE Pleural Space RA RV LA MV TV AOV Ao PV/PA Veins Shunts More Wall Scoring LT = Practice Car Color # Prior Interventions Prosthetic Valves Car Color M #-Pulmonary Veins @- Pulmonary Veins-ASE O red O green @ PV D- PV-ASE O blue O white @ RA-ASE O black O silver RV yellow + RV-ASE + RVOT @-SD D- SD TEE D- SDIS mapping . Situs Sonographer Comments # Stress echo Study Find: Calc Type Cardiac Item: Car Color(Practice) Context: Study Associated Phrases Properties Columns 1 Display Name Car Color Format Expanded Read Only No Show Borders Yes Column's lumber of columns. This is used in both Collapsed and Expanded formats. It is always - 1 8. Properties can be edited: a. Columns allows user to decide if the Observations will display vertically or horizontally. b. Display Name may be changed to anything desired. c. Format can be set for expanded or collapsed. Expanded omits an extra mouse click for the end user. Collapsed allows conservation of space on the Worksheet. d. Read Only is for a field that should NOT be manipulated on the worksheet. e. Show Borders is an aesthetic choice for the user. Item: Car Color(Practice) Context: Study Associated Phrases ... . Properties Columns 1 Display Name Car Color Format Expanded Read Only No Show Borders Yes www.usa.siemens.com/healthcare SIEMENS Page 4 of 6 9. The Observation can be moved anywhere on the Worksheet page by clicking and dragging or using the keyboard arrow keys (suggested if moving an observation on a crowded worksheet). XSD Adult Echo Expanded.kwt RA RV LA MV TV AOV Ao PV/PA Veins Shunts More Wall Scoring LT Car Color O red O green O blue O white O black O silver O yellow 10. To Delete an observation from the Worksheet, Highlight the Observation and use the Delete Key. The Observation remains in the Data Palate and can be reinserted if needed. 11. At the end it is important to save your work. It is recommended File Edit View Libraries Tools Help New to be in the habit of the following save options below after ALL Open Ctrl+O Close work. Work can never be over-saved!! Save Worksheet Ctrl+ Save Worksheet As ... Save Report "sD Adult Echo.kit" Save Report "sD Adult Echo.kit" As .. Save All Load Previously Saved Report Load Previously Saved Worksheet Preferences Print Preview Print Worksheet Properties Report Properties Exit SIEMENS www.usa.siemens.com/healthcare Page 5 of 6 On account of certain regional limitations of Local Contact Information sales rights and service availability, we cannot guarantee that all products included in this Siemens Medical Solutions USA, Inc. brochure are available through the Siemens 51 Valley Stream Parkway sales organization worldwide. Availability and Malvern, PA 19355-1406 packaging may vary by country and is subject USA to change without prior notice. Some/All of the Phone: +1-888-826-9702 features and products described herein may not www.usa.siemens.com/healthcare be available in the United States. The information in this document contains Global Business Unit general technical descriptions of specifications and options as well as standard and optional Siemens AG features which do not always have to be present Medical Solutions in individual cases. X-ray Products Henkestr. 127 Siemens reserves the right to modify the design, DE-91052 Erlangen packaging, specifications and options described Germany herein without prior notice. Please contact your Phone: +49 9131 84-4746 local Siemens sales representative for the most www.siemens.com/healthcare current information. Note: Any technical data contained in this document may vary within defined tolerances. Original images always lose a certain amount of detail when reproduced. Global Siemens Headquarters Global Siemens Legal Manufacturer Healthcare Headquarters Siemens AG Siemens AG Wittelsbacherplatz 2 Siemens AG Wittelsbacherplatz 2 80333 Muenchen Healthcare Sector DE-80333 Muenchen Germany Henkestrasse 127 Germany 91052 Erlangen Germany Phone: +49 9131 84-0 www.siemens.com/healthcare www.siemens.com/healthcare 1 All rights reserved | © 2014 Siemens Medical Solutions USA, Inc.
- syngo X Workplace