syngo Electrophysiology Guidance - syngo Application Software VD20
syngo Electrophysiology Guidance syngo Application Software VD20 Using pre-procedure CTA or MRI data for planning Using DynaCT data for planning Load the CTA or MRI data. Start 3D Wizard and select a LA Imaging program (alternatively use a 5s DR Card). Start syngo EP Planning. Segmentation ✔ Auto segmentation is selected by default. auto The left atrium (LA) is segmented automatically. Optional: Perform a 1-click LA segmentation or a stroke-based segmentation. Sculpt the segmentation result, if necessary. +H A A: Export the segmentation result to external A B electro-anatomical mapping system. B Lesion Planning Mark points on the segmentation result to indicate locations where you plan to apply ablation. Display and Guidance Align the VRT segment to an optimal working projection. Move C-arm to match 3D image angulation. Select syngo 3D Roadmap (overlay live image to 3D image) to overlay 3D volume on fluoroscopy for guidance. You can use this for navigating with fluoroscopy, positioning the tip of the abla- tion catheter to the desired locations. During the procedure, single mouse click on the existing points to mark them as “ablated”, if necessary. Add new ablated points, if necessary. Effective Date: 12.07.2018 | HOOD05162002976352 SIEMENS Healthineers siemens.com/healthineers VD20 Job Aid | syngo Electrophysiology Guidance Effective Date: 12.07.2018 | HOOD05162002976352 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (herein- after collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be upd ated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2019 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019
- syngo Electrophysiology Guidance - syngo Application Software VD20