syngo FLC Reprocessing RAD Images

This job aid will guide the end user through the steps to reprocess RAD images.

syngo FLC: Reprocessing Rad Images FLUOROSPOT Compact (syngo FLC) For improvement of the image content, different filters for spatial frequency can be applied: • DiamondView Plus for adoption of the overall image content • Harmonization for reducing the image dynamics • Edge enhancement for sharpening as well as noise suppression DiamondView Plus DiamondView Plus is a special preprocessing process which is used for adaptation to the overall image content. Harmonization and edge enhancement are automatically adjusted, but can also be changed through manual entries. Basic adjustments of the parameters are made by service. Harmonization Process. Graphics Rad Harmonization is a method of image processing that emphasizes the detail contrast of small structures by contrast compensation of coarse Auto-cropping structures. Both the local frequency (size of the brightness/absorption Set black differences) and the degree of reduction can be set. Auto-window With the Gain you define the degree of reduction of the brightness Amplification 5.6 Auto differences: • Gain larger: more contrast compensation (lower dynamics) n. • Gain smaller: less contrast compensation • Gain = 0%: no contrast compensation 14INx17IN With the Kernel you define the extension of the reduced brightness Thorax pa differences: 1 Thorax pa - high contrast • Kernel larger: larger extended brightness differences are reduced Noise Reduction • Kernel smaller: smaller extended brightness Edge. Gain 0.00 differences are reduced Kernel 7 Harm. Gain 0.00 : Kernel 255 : SIEMENS Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2021 Master Template Effective Date: 5 MAR 2020 | HOOD05162003074494 Healthineers Job Aid Effective Date: 06 I 07 I 2021 | HOOD05162003199303 Job Aid | syngo FLC: Reprocessing Rad Images Effective Date: 06 I 07 I 2021 | HOOD05162003199303 Edge enhancement Depending on the organ program (organ to be examined, dose, … ), Process. Graphics Rad better display of edges or better noise suppression might be required. This is defined in the organ programs but can be changed Auto-cropping subsequently. Set black Auto-window In the Edge Enhancement area, you can change the following parameters: Amplification 5.6 Auto • With the Kernel you define the size of the details for edge enhancement / noise suppression: n. o Kernel smaller: finer o Kernel larger: coarser 14INx17IN With the Gain you define the degree of edge enhancement / Thorax pa • noise suppression: 1 Thorax pa - high contrast o Positive: higher contrast (drawback: more noise) Negative: less noise (drawback: edges blurred) Noise Reduction o Edge. Gain 0.00 : Please note: Since VF10C, special filtering settings are available for Kernel tube and line enhanced views of the image: Tube and Line 1 and Harm. Gain 0.00 : Tube and Line 2. These two modules use a special combination of harmonization and edge enhancement parameters to visualize tubes, Kerne 255 : catheters, and cables. SIEMENS Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2021 Healthineers Master Template Effective Date: 5 MAR 2020 | HOOD05162003074494 Job Aid Effective Date: 06 I 07 I 2021 | HOOD05162003199303 Job Aid | syngo FLC: Reprocessing Rad Images Effective Date: 06 I 07 I 2021 | HOOD05162003199303 Gradation curve (LUT) The system contains a number of gradation curves (Look-Up Table: Process. Graphics Rad LUT). Depending on the organ, different LUTs are available for organ- ........................................... ‘ ‘ to- oriented display and are already stored in the predefined organ Auto-croppingi Set black programs. v Auto-window You can select another LUT in the organ program or edit the LUT on Amplification 2.00 - Auto the Rad subtask card in Postprocessing mode. Please note: LUT and window settings must be well balanced. Normally this is done automatically after acquisition by the Auto- window function. If the LUT has been changed manually, either a 14INx17IN repetition of the Auto-window must be performed or the window settings must be adjusted manually. 3 Setting the gradation curve (LUT) Click this icon. The gradation parameters are displayed. Select a suitable gradation curve (LUT) from the selection list: LUT Description 1 Linear, bones black - Service only 2 Linear, bones white - Service only 3 Logarithmic 4 Skull, hip 5 Thorax, conventional film impression 6 Shoulder, polyarthritis (soft tissue), extremities 7 Customer specific solution - is normally not used 8 Thorax interstitial lung tissue 9 Same as 3, higher contrast 10 Abdominal examinations 11 Ribs 12 Extremities 13 Cervical spine 14 Thorax mediastinum / retro cardial 15 Spine, abdomen high contrast SIEMENS Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2021 Healthineers Master Template Effective Date: 5 MAR 2020 | HOOD05162003074494 Job Aid Effective Date: 06 I 07 I 2021 | HOOD05162003199303 Job Aid | syngo FLC: Reprocessing Rad Images Effective Date: 06 I 07 I 2021 | HOOD05162003199303 Defining the gradation curve 1. Click this icon. The Optimize Image window is displayed. Optimize Image X Gradation Data LUT and HISTOGRAM 4096 Gradation ID 7 Shape g_lut_12 Contrast 1.5 Center 3072 Offset 100 : 2048 Amplification 2. Output Signal DEFAULT GRADATION PARAMETERS Histogram ROI 512 1024 1536 2048 2560 3072 3584 4096 0 nput Signal (log) XUL 4 YUL 10 XLR 3004 YLR 2374 View O Logarithmic Full range linear O Zoom 1 linear O Zoom 2 linear OK Apply Cancel 2. Select the required View. 3. Change the Gradation Data parameters to your needs. 4. To reset changed values to the values before opening the dialog, click DEFAULT GRADATION PARAMETERS. The Histogram ROI parameters are displayed. 5. Click OK. Confirming reprocessing If every parameter matches your requirements: • Click the apply icon. All processing is done. After a few seconds, the processed image is displayed. SIEMENS Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2021 Healthineers Master Template Effective Date: 5 MAR 2020 | HOOD05162003074494 Job Aid Effective Date: 06 I 07 I 2021 | HOOD05162003199303 Job Aid | syngo FLC: Reprocessing Rad Images Effective Date: 06 I 07 I 2021 | HOOD05162003199303 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2021 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com SIEMENS Healthineers Unrestricted

  • reprocessing
  • syngo
  • flc