syngo FLC Transfer Formats

This job aid covers the steps for transferring formats on the syngo FLC software.

syngo FLC: Transfer Formats FLUOROSPOT Compact (syngo FLC) Each of the various image formats for archiving/storage supports different image information. Therefore, depending on the selected format, not all image information might be stored, i.e., you don’t have the same state after restoring than before storage. • Private: The images are stored in a Siemens format. o Advantage: Full information including original data is transferred. o Disadvantage: This format is not compatible with other systems. • DICOM SC: Images are stored as DICOM Secondary Captures. o All image graphics are “burnt-in”. The image can be viewed in the current state on any capable system (WYSIWYG). o Series are converted to single images. o Not all image parameters are retained, e.g., no kV, mAs. • DICOM XRF: Images are stored in the DICOM XRF/XA format. o Series are stored as multiframes. o Image graphics and text are in the overlay plane. o Image parameters are retained. o DSA series are stored subtracted. • DICOM XRF Full: Like DICOM XRF but: o Series are non-processed multiframes, i.e., they can be postprocessed further. o DSA series are stored non-subtracted. • Processed: Option for DICOM XRF and DICOM XRF Full: o Images are ready processed, i.e., shutter, panning, and graphics will be “’burned” into pixel data. • DICOM CR: RAD images are stored in the DICOM CR/DX format. o All image graphics are “burnt-in”. o Image parameters are retained. • TIFF: Single images can be converted to the standard TIFF format (8 bits). AVI: Series can be converted to a movie in the AVI format (uncompressed). o Only pixel image with “burnt-in” graphics. o Reduced grayscale information (8 bits) Please note: Image header and pixel information is restricted to the DICOM standard. Especially when storing in the DICOM SC format, the following information will get lost: • in the image: kV, mAs • in the exam protocol: Dose area product (accumulated), Fluoro time (accumulated), Cu filter, and input format SIEMENS Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2021 Master Template Effective Date: 5 MAR 2020 | HOOD05162003074494 Healthineers Job Aid Effective Date: 06 I 22 I 2021 | HOOD05162003197809 Job Aid | syngo FLC: Transfer Formats Effective Date: 06| 22 | 2021 | HOOD05162003197809 The following image storage formats are supported by this system: Image format DFR RAD via CD / DVD / USB via network Private + + Yes No DICOM SC + Yes Yes - DICOM XRF + Yes Yes - CICOM XRF Full + Yes Yes - Processed + Yes Yes - DICOM CR + Yes Yes - TIFF, AVI + + Yes No Please note: Use only DICOM formats for image archival. Forward compatibility of the Private format is not guaranteed. Please note: TIFF images or AVI movies can be viewed on another PC. It is not possible to import or view images in TIFF, JPEG, or other formats or movies in AVI or other formats on the FLUOROSPOT Compact imaging system. SIEMENS Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2021 Healthineers Master Template Effective Date: 5 MAR 2020 | HOOD05162003074494 Job Aid Effective Date: 06 I 22 I 2021 | HOOD05162003197809 Job Aid | syngo FLC: Transfer Formats Effective Date: 06| 22 | 2021 | HOOD05162003197809 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2021 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com SIEMENS Healthineers Unrestricted