syngo LungCare Follow Up Exam
syngo LungCare Follow Up Exam step by step
syngo LungCare Follow Up Exam Computed Tomography syngo LungCARE CT offers a streamlined workflow for evaluating suspicious physician identified lung nodules over time and comparing current findings to a previous examination. 1. To perform a follow up examination on a patient and compare a lesion between two time points, load the prior examination from the Patient Browser into the syngo LungCARE appli- cation via Applications > CT > LungCARE. Re-open the Patient Browser and repeat with the current examination. The system will prompt you replace the loaded study or to load the second as a follow up. Select Follow Up. Question X Load second dataset for Follow Up examination or replace data set? Follow Up Replace Cancel 2. Scroll through the images in segment 1 to review the examination. Any previously- evaluated lesions will be displayed in green on the prior study. CT_LungCARE_F/1 Anlagenzentrum 454 Sensation 15 *1/11/1939, M. 63Y STUDY 1 10/23/2002 08:43:02.50 3 IMA O MIP THIN 2R F F114.3 SL 7.0 2 1200 SIEMENS siemens.com/healthineers Healthineers . Job Aid | syngo LungCare Follow Up Exam Effective Date: 8/16/2016 | Quality 625 3. The system can propagate the lesion marker from the prior study (segment 1) to the current study (segment 2). Hold the right mouse button down on the prior lesion to access the pin- wheel submenu. Select Get Counterpart. The lesion will be identified in a red box on the current examination. CT_LungCARE_F/U1 Anlagenzentrum CT_LungCARE_F/U1 Anlagenzentrum 454 Sensation 16 454 Sensation 16 #1/11/1939, M. 63Y VA508 *1/11/1939, M, 64Y VASOA STUDY 1 STUDY 1 10/23/2002 2/5/2003 08:43.02.50 09:43:31.32 3 MA 0 3 IMA 0 MIP THIN MIP THIN 2R SPF114.3 SP F664.0 SL 7.0 ₩ 1200 SL 7.0 ₩ 1200 C -400 4. In segment 2, hold the right mouse button down on the current lesion to access the pinwheel submenu and create a VOI. Both the current and prior lesion will be updated. CT_LungCARE_F/1 Anlagenzentrum CT LungCARE_F/U1 Anlagenzentrum 454 Sensation 16 Sensation 16 #1/11/1939, M. 63Y VA50B 4/11/1939, M, 64Y VA60A STUDY 1 10/23/2002 2/5/2003 08:43:02.50 09:43:31.32 3 MA 0 3 IMA O PYRT PVRT Nodule ID: Status: reporte Volume [mm3]. 324.23 X-Diameter [mm]: 7.70 Y-Diameter [mm]: 9.10 Z-Diameter [mm]: 7.70 Min. Diameter [mm]. 7 44) Max. Diameter [mm]: 3.67 Density average [HU): 52.25 Density stddev [HU]: 48.25 Algorithm: AllSizeNodule F F VOI-Size [mm]: 40 SL 0.35 SL 0.35 5. Hold the right mouse button down on the new lesion again (segment 2) to access the pin- wheel submenu and Evaluate Nodule. Siemens Healthineers Services Page 2 of 4 Job Aid | syngo LungCare Follow Up Exam Effective Date: 8/16/2016 | Quality 625 6. Hold the right mouse button down on the new lesion a third time (segment 2) to access the pinwheel submenu and Report Nodule. The Nodule Details dialog box will appear allow- ing you to further characterize the lesion as to location, shape, etc. Here you will also see that the two lesions - current and prior - have been Linked. Nodule Details: ID 2 x Counterpart ID 2 In Linked Location L3 New ? no Shape compact Edges well defined Calcification no Cavitation no Comment Select Reference Images OK Cancel To view comparative lesion details, open the Report Wizard using the blue envelope icon. The Nodule Information will display the lesion Growth (%) and estimated Volume Doubling Time (days). Nodule Information Other Abnormalities ID Volume Algorithm Location Max. @ Min. @ Growth Volume Doubling Density average [mm] [mm] [mm] [x] Time [days] [HU] 331.63 AllSizeNo. L3 9.74 2.38 2.26 55.53 Siemens Healthineers Services Page 3 of 4 Job Aid | syngo LungCare Follow Up Exam Effective Date: 8/16/2016 | Quality 625 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright @ Siemens Healthcare GmbH ...... ........... Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 4 of 4