syngo Neuro PBV IR
syngo Neuro PBV IR
syngo® Neuro PBV IR Interventional Radiography: Vascular This workflow is based on a manual power injection and with an IV injection site. Prepare power injector with contrast and possibly saline, depending on type of power injector available. 1. Select the Neuro PBV organ program from the Exam Set Editor or Touch *Screen Controls. 2. Set up for 3D following prompts on Assist Monitor. Injection Recommendation Typically start the IV injection about 2 seconds before starting the Mask Run Dual Head Injector|60ml CM at 4-5ml/s and then followed by 60ml NaCl at 4-5ml/s Single Head Injector|80ml CM at 4-5ml/s without NaCl Examination Sequence 1. Start IV injection then press the acquisition button or pedal. Keep this button or pedal pushed for the entire sequence. 2. Manually start the Mask Run by pushing and releasing blue multifunction button on handswitch. Mask images are acquired. 3. C-arm returns 4. Bolus Watching Phase-when c-arm returns to starting position, a 2D DSA run will be displayed on the Artis LIVE monitor. Based on image content (usually upon first visualisation of CM in Superior Sagittal Sinus), manually start Fill Run. Again, press and release the blue multifunction button on handswitch. 5. 3D acquisition is complete when doorbell is heard and/or 3D Completed is displayed on Assist Monitor. 6. 3D data is automatically sent to the syngo Workplace, reconstructed, and displayed. I Sequence Example: start CM end CM start saline end saline veins visible 4 Scan Direction Scan Direction Rotate back Patient patient Bolus Watching (<30s) patient 8s 5s Xs 8s Contrast Material Saline chaser 60ml@5ml/s 60ml@5ml/s 12s injection time 12s injection time Total scan time: 13s + Xs (Bolus Watching) + 8s ~30s SIEMENS siemens.com/healthineers Healthineers . Job Aid | syngo® Neuro PBV IR Effective Date: 09/08/2016 | Quality HOOD05162002274383 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright @ Siemens Healthcare GmbH ........... Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 2 of 2
- Angiography/Interventional Imaging
- Angiostar
- Artis One
- Artis zee
- Artis Zeego
- Axiom Artis