syngo.via - Cinematic Rendering
syngo.via - Cinematic Rendering Step by Step
syngo.via® Cinematic Rendering Cinematic Rendering enables photorealistic 3D views of CT and MR datasets through highly sophisti- cated photon simulations and advanced graphics capabilities. Cinematic Rendering can benefit clini- cal imaging for surgery planning and can also help physicians relay complex anatomical information to their patients. Cinematic Rendering is currently available on syngo.via in MM Reading, CT Vascu- lar, CT Coronary, and CT Cardiac Planning. 1. From the lower left segment menu of any segment, select “Cinematic VRT” Angio View Cinematic VRT HD VRT MIP MPR HAL HLP RPH RPH Classic VRT Cinematic Rendering Compared to a classic VRT, Cinematic Rendering utilizes a monte-carlo based photon simulation that allows for the visualization of more dynamic ranges and shading, for a significantly-improved realis- tic look. When windowing a Cinematic VRT, the image will revert to a classic VRT until the mouse is released. The progressive rendering process will then continuously improve the quality of the displayed image. Cinematic Rendering supports table removal, bone removal, and the punch mode as in classic VRT. Snapshots can be created and images can be printed or exported directly to PACS. * Cinematic VRT is for communication, education and publication purposes and not intended for diagnostic reading. Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 05/15/2017 | HOOD05162002591611 Healthineers Job Aid | syngo.via Cinematic Rendering Effective Date: 05/15/2017 | HOOD05162002591611 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 05/15/2017 | HOOD05162002591611 Healthineers Page 2 of 2
- syngo.via - Cinematic Rendering