syngo.via CT VB50 Delta Online Training
This online training is intended to train you on new features and improvements of the syngo.via VB50 software version that covers Computed Tomography.
This course is best viewed on either a tablet, laptop, desktop or connected monitor. Not recommended to view on a smartphone.
Continue Continue syngo.via CT VB50 Delta Online Training syngo.via CT VB50 Delta Online Training In this training you will learn about new features and improvements of the syngo.via VB50 software version that covers Computed Tomography. Understand the rule-based configuration for syngo.via Rapid Results Technology 1 Configure Rapid Results Technology Assignments 2 Master Template HOOD05162003052540 | Effective Date: 26-Nov-2019 Welcome [audf_sv_vb50_delta_olt_ct_welcome.mp3] Audio Script: Welcome to the syngo.via CT VB50 Delta Online Training. In this training you will learn about new features and improvements of the syngo.via VB50 software version that covers Computed Tomography. By the end of this training, you will be able to understand the rule-based configuration for syngo.via Rapid Results Technology and to configure Rapid Results Technology Assignments. Let’s get started. Hints for Navigating this Online Training Before you start, we would like to give you a few tips on how to navigate: Table with 2 columns and 3 rows Not all pages contain audio. Some pages invite you to read for yourself or watch a video. Some pages show an X button in the upper right corner. Click the X button to return to the overview page and not miss any information provided. Some images show a magnifier icon. Click on the icon to see an enlarged view of the image. Another click brings you back to the normal view. Enjoy the course! Hints for Navigation syngo.via Rapid Results Technology – Rule-based configuration – New with syngo.via VB50 With syngo.via VB50, we are introducing a new option for generating automated results: Rule-based result generation This enables automated results for the complete Siemens Healthineers CT scanner fleet since the configuration is done only at syngo.via. This also allows the creation of automated results for data from other CT-vendors (license-protected feature)*. *syngo.CT vendor-independent RRT depends on the behavior of the specific CT Application e.g. syngo.CT CaScoring, by allowing postprocessing with the CT DICOM data from non-Siemens Healthineers CT scanners. Therefore, the CT Dual Energy Application only supports spectral data from Siemens Healthineers CT scanners and syngo.CT vendor-independent RRT cannot handle spectral data from other vendors. syngo.via Rapid Results Technology - Rule-Based Configuration [audf_sv_vb50_delta_olt_ct_rule-based-configuration.mp3] Audio Script: With syngo.via VB50 we are introducing a new option for generating automated results: Rule-based result generation This enables automated results for the complete Siemens Healthineers CT scanner fleet since the configuration is done only at syngo.via. This also allows the creation of automated results for data from other CT-vendors (license-protected feature). syngo.via Rapid Results Technology – Rule-based configuration You can create rules that are applied to incoming data and trigger the result generation. As a clinical administrator, you can configure and manage rules in the syngo.via Configuration Panel by using keywords or conditions that are part of the DICOM Image Header. Introduction [audf_sv_vb50_delta_olt_ct_rbc-introduction.mp3] Audio Script: You can create rules that are applied to incoming data and trigger the result generation. As a clinical administrator, you can configure and manage rules in the syngo.via Configuration Panel by using keywords or conditions that are part of the DICOM Image Header. Rule-based configuration Without the license-protected* feature, only data from Siemens Healthineers CT scanners will be calculated, as indicated by the note: “This only effects Siemens scanner data.” *syngo.CT vendor-independent RRT depends on the behavior of the specific CT Application e.g. syngo.CT CaScoring, by allowing postprocessing with the CT DICOM data from non-Siemens Healthineers CT scanners. Therefore, the CT Dual Energy Application only supports spectral data from Siemens Healthineers CT scanners and syngo.CT vendor-independent RRT cannot handle spectral data from other vendors. Rule-Based Configuration [audf_sv_vb50_delta_olt_ct_rbc-license-protected.mp3] Audio Script: Without the license-protected feature only data from Siemens Healthineers CT scanners will be calculated, as indicated by the note: “This only effects Siemens scanner data.” Rapid Results Technology On the access bar, click the menu icon and choose Configuration > Configuration Panel to open the Configuration Panel. Click the Advanced Visualization tab to make the Rapid Results Technology section available. The Activate Rapid Results Technology check box is selected by default. syngo.via Rapid Results Technology (RRT) is enabled. Rapid Results Technology [vid_sv_vb50_delta_olt_ct_enable-rrt.mp3] Video Script: On the access bar, click the menu icon and choose Configuration > Configuration Panel to open the Configuration Panel. Click the Advanced Visualization tab to make the Rapid Results Technology section available. The Activate Rapid Results Technology check box is selected by default. syngo.via Rapid Results Technology is enabled. Configuring results based on result types As a clinical administrator, you can configure results in the syngo.via Configuration Panel. The configuration is valid for your institution. The dedicated clinical RRT results are part of the clinical Applications, e.g. Rapid Results Technology of total CaScore is included in the syngo.CT CaScoring license. The following result types are available: Parallel Ranges Radial Ranges Spine Ranges Rib Ranges Parallel Vascular Ranges Radial Vascular Ranges CT CaScoring Lung CAD * syngo.CT NeuroPerfusion is pending 510(k) clearance and is not yet commercially available in the United States. ** ASPECTS is not for sale in the United States. Its future availability cannot be guaranteed. CT Neuro Perfusion* CT ASPECT Score** RT Auto Contouring Configuring Results Based on Result Types [audf_sv_vb50_delta_olt_ct_configuring-results.mp3] Audio Script: As a clinical administrator, you can configure results in the syngo.via Configuration Panel. The configuration is valid for your institution. The dedicated clinical Rapid Results Technology results are part of the clinical Applications, e.g. Rapid Results Technology of total Calcium Score is included in the syngo.CT CalciumScoring license. The following result types are available: [result types are only shown in screen text] Configuring Rapid Results Technology Assignments Click on the scanner icon to open the configuration of rules Under Configure Rapid Results Technology Assignments, new rules for the generation of RRTs can be set up This configuration provides linking from DICOM attributes to configured RRT protocols Click on the + icon to create a new rule Configuring Rapid Results Technology Assignments [vid_sv_vb50_delta_olt_ct_configure-rr-assignments.mp3] Video Script: Click on the scanner icon to open the configuration of rules. Under Configure Rapid Results Technology Assignments, new rules for the generation of Rapid Results Technology can be set up. This configuration provides linking from DICOM attributes to configured Rapid Result protocols. Click on the + icon to create a new rule. How to use wildcards/placeholders In the Configuration window, click on the icon … Examples to get information on how to create rules. Wildcards/Placeholders [vid_sv_vb50_delta_olt_ct_wildcards.mp3] Video Script: In the Configuration window, click on the icon … Examples to get information on how to create rules. How to use wildcards/placeholders (examples) Text strings are context-sensitive, for example, Thorax and thorax will not lead to the same results. You can use * as a wildcard character. Examples: Table with 3 columns and 6 rows Rule Matching Recon Head*1.5*Coronal Head 1.5 Hr60 Coronal Yes Head 1.5 Coronal contrast No - “contrast” at the end Head 1.5 coronal No - context-sensitive Head/Neck 1.5 Coronal Yes Head/Neck 1.5 Hr60 Coronal Yes Wildcards/Placeholders (Examples) [audf_sv_vb50_delta_olt_ct_wildcards-example.mp3] Audio Script: Text strings are context-sensitive, for example, Thorax with an uppercase letter and thorax with a lowercase letter will not lead to the same results. You can use an asterisk as a wildcard character. Available parameters for configuration of rules The following parameters are available to create rules: Study Description Series Description Additional Condition (Optional) Contrast Media Kernel Scan Protocol Name Scanner Manufacturer Scanner Name Available Parameters for Configuration of Rules [vid_sv_vb50_delta_olt_ct_parameters-for-configuration.mp3] Video Script: The following parameters are available to create rules: Study Description Series Description and an optional Additional Condition. How to create a new rule (example) All parameters for creating new rules are available in the Patient Browser either on the patient level or on the series level. After selecting Add new Rule, e.g. to create a rule for CT CaScoring, open the Patient Browser to verify the best setting for Study or Series description. The Configuration window is a floating window which will not close while using or viewing e.g. the Patient Browser. How to Create a New Rule (Example) [vid_sv_vb50_delta_olt_ct_rbc-example.mp3] Video Script: All parameters for creating new rules are available in the Patient Browser either on the patient level or on the series level. After selecting Add new Rule e.g. to create a rule for CT Calcium Scoring, open the Patient Browser to verify the best setting for Study or Series description. The Configuration window is a floating window which will not close while using or viewing e.g. the Patient Browser. Combination of parameters with existing clinical results (RRTs) In the last column, Rapid Results Technology Results, you can select the available clinical results* of Rapid Results Technology (RRT) for the conditions. *The dedicated clinical RRT results are part of the clinical Applications, e.g. Rapid Results Technology of total CaScore is included in the syngo.CT CaScoring license. Combination of Parameters with Existing Clinical Results (RRTs) [vid_sv_vb50_delta_olt_ct_results.mp3] Video Script: In the last column Rapid Results Technology Results you can select the available clinical results of Rapid Results Technology for the conditions. Configure Rapid Results Technology Assignments Understand the rule-based configuration for syngo.via Rapid Results Technology Course Review Congratulations. You have completed the syngo.via CT VB50 Delta Online Training course. Select the objectives listed below to review the material before proceeding to the final assessment. 1 1 1 2 2 2 Course Review Configure Rapid Results Technology Assignments In the Configuration Panel > Advanced Visualization > Rapid Results Technology, click on the scanner icon to open the Configuration window. Click on the + icon to create a new rule. The following parameters are available: Study Description, Series Description, optional Additional Condition (Contrast Media, Kernel, Scan Protocol Name, Scanner Manufacturer, Scanner Name) You can use * as a wildcard character for rule descriptions. Incoming Series are checked for a match with the rule descriptions. If there is a match, the series trigger a Rapid Results Technology calculation which you can specify in the Rapid Results Technology Result column. Table with 5 columns and 2 rows When Study Description is: AND when Series Description is: AND Additional Condition is: With Additional Value : Calculate this Rapid Results Technology Result : *CACT* *CASC_3.0* Contrast Media No CT CaScoring Example: syngo.via Rapid Results Technology – Rule-based configuration With rule-based configuration, you can create rules that specify how incoming series trigger Rapid Results Technology calculations. This enables automated results for the complete Siemens Healthineers CT scanner fleet. It also allows the creation of automated results for data from other CT-vendors (license-protected feature). As a clinical administrator, you can configure and manage rules in the syngo.via Configuration Panel by using keywords or conditions that are part of the DICOM Image Header. Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters / Siemens Healthcare GmbH / Henkestr. 127 / 91052 Erlangen, Germany Telephone: +49 9131 84-0 / siemens-healthineers.com Disclaimer Disclaimer Assessment This assessment will test your retention of the presented content. A passing score of 80% or higher is required to complete the course and earn your certificate. You may repeat the assessment as many times as needed. Start Assessment In the configuration of the Siemens CT scanner At syngo.via in the Configuration Panel – Advanced Visualization At syngo.via in the Administration Portal Where can you find the syngo.via Rapid Results Technology – Rule-based configuration? Question 1 of 5 Select the best answer. Question 1 Incorrect Correct Correct This statement is correct but it is a license-protected feature. Data role configuration can be done for Siemens scanners only. Data role configuration is not available on syngo.via. syngo.CT vendor-independent RRT depends on the behavior of the specific CT Application e.g. syngo.CT CaScoring, by allowing postprocessing with the CT DICOM data from non-Siemens Healthineers CT scanners. Question 2 of 5 Select the best answer. Question 2 Incorrect Correct Correct Head Hr60 Coronal Head 1.5 Coronal contrast Head/Neck 1.5 Coronal Head 1.5 coronal In “Configure Rapid Results Technology Assignments” on syngo.via you can use * as wildcard character. Question 3 of 5 Select the match with the rule „Head*1.5*Coronal”. Question 3 Incorrect Incorrect Incorrect Correct Study Description, Series Description, Optional Additional Condition (e.g. Contrast Media, Kernel, Scan Protocol Name) Workflow Description, Study Description, Series Description Study Description, Series Description, Optional Study Date What parameters are available for creating rules in “Rapid Results Technology Assignments”? Question 4 of 5 Select the best answer. Question 4 Incorrect Correct Correct Yes, because the Configure Scanner Assignment window is a floating window. No, the Configure Scanner Assignment window will close as soon as a different platform is active. Yes, but the Configure Scanner Assignment window has to be opened on a second screen. Can the window to “Configure Scanner Assignment” and the Patient Browser be viewed simultaneously? Question 5 of 5 Select the best answer. Question 5 Incorrect Incorrect Correct Review Review Retry Assessment Results %Results.ScorePercent%% %Results.PassPercent%% Continue YOUR SCORE: PASSING SCORE: Assessment Results You did not pass the course. Take time to review the assessment then select Retry to continue. Congratulations. You passed the course. Exit To access your Certificate of Completion, select the Launch button drop down on the course overview page. You can also access the certificate from your PEPconnect transcript. You have completed the syngo.via CT VB50 Delta Online Training. Completion syngo.via CT VB50 Delta OLT [HOOD05162003114322 | Effective Date: 30 AUG 2020] 1.1 Welcome 1.2 Hints for Navigation 1.3 syngo.via Rapid Results Technology - Rule-Based Configuration 1.4 Introduction 1.5 Rule-Based Configuration 1.6 Rapid Results Technology 1.7 Configuring Results Based on Result Types 1.8 Configuring Rapid Results Technology Assignments 1.9 Wildcards/Placeholders 1.10 Wildcards/Placeholders (Examples) 1.11 Available Parameters for Configuration of Rules 1.12 How to Create a New Rule (Example) 1.13 Combination of Parameters with Existing Clinical Results (RRTs) 1.14 Course Review 1.15 Disclaimer 1.16 Assessment
- syngo.via
- VB50
- Computed Tomography
- Delta
- syngovia
- snygo
- via