syngo.via MR Breast Job Aid
This MR Breast job aid provides information about dynamic layout, findings, and additional configuration with syngo.via.
SIEMENS Healthineers MR Breast Job Aid Template Effective Date: 27 May 2019 | HOOD05162003010284 Job Aid Effective Date: 03 Sep 2021| HOOD05162003217487 Unrestricted © Siemens Healthineers, 2021 MR Breast SIEMENS Healthineers Table of Contents Overview 3 MR Breast A Q + MR Breast Reading Dynamic Layout 4 click Learn Segments Findings 5 Dynamic Morphology 1 Additional Configuration 7 Morphology 2 Multiple time points MC 1 Min / Max: 67.00 /297.00 Viewing Mean/SD: 240.16 /32.73 Area: 0.55 cm2 Findings Breast Ratio (%) Breast MR Breast 2 175 MC 1 SP H9 .9 Distance to chest wall MRI Br ... Distance to skin MRI Br ... 50 Distance to nipple MRI Br ... MC 1 0.55 c ... 100 175 Tools 50 Synch Align Full Text Hide Hide Lines Reset Graphics Timepoi ... 25 Lasdit Snapshot Print Export Undo Redo Image Image 50 100 150 200 250 300 350 400 450 500 10:58 AM Normal time (sec) 2 Effective Date: 03 Sep 2021| HOOD05162003217487 Unrestricted © Siemens Healthineers, 2021 MR Breast SIEMENS Healthineers Overview In the MR Breast workflow, you A MR Breast Q + MR Breast Reading can read and analyze images of the breast by using the automatic angle Learn Segments Dynamic synchronization of series and Morphology 1 R Morphology 2 Multiple time points MC 1 on-the-fly mean curve analysis. Min / Max: 67.00 /297.00 Viewing Mean/SD: 240.16 /32.73 Area: 0.55 cm2 II The MR Breast workflow has Findings Breast Ratio (%) Breast MR Breast 2 175 MC 1 Distance to chest wall MRI Br ... SP H9.9 5 preconfigured reading steps: Distance to skin MRI Br ... 150 Distance to nipple MRI Br ... MC 1 0.55 c ... • Dynamic 125 100 • Morphology 1 75 • Morphology 2 Tools L Synch Align Full Text Hide Hide Lines Reset Graphics Timepoi ... • Multiple time points 25 Edit Snapshot Print Export Undo Redo • Viewing Layout Image Image 50 100 150 200 250 300 350 400 450 500 Normal time (sec) 10:58 AM 3 Effective Date: 03 Sep 2021| HOOD05162003217487 Unrestricted © Siemens Healthineers, 2021 MR Breast SIEMENS Healthineers Dynamic Layout In the Dynamic Layout of MR A MR Breast Distance Line MR Breast Reading ROI Circle Breast, you can easily analyze Pixel Lens Marker Single -17 Learn enhanced curves. Segments Arrow Dynamic Angle Morphology 1 Text T R Morphology 2 MC-Circle The following measurement tools Multiple time points MC Min / Max: 67.00 /297.00 Viewing Mean/SD: 240.16 /32.73 Area: 0.55 cm2 are available: • MC-Circle Findings • MC-Pixel Lens Breast Ratio (%) Breast MR Breast 2 175 MC1 Distance to chest wall MRI Br ... • MC-Freehand Dynamic Distance to skin MRI Br ... 150 Distance to nipple MRI Br ... MC 1 0.55 c ... 125- 100 Use the arrow keys on the keyboard 75 to navigate through the phases. Tools L 50 Alian Full Te Reset Graphic. Timepoi ... 25 Edit Snapshot Print Export Undo Redo 0 Image Image 0 50 100 150 200 250 300 350 400 450 500 Normal time (sec) 11:18 AM 4 Effective Date: 03 Sep 2021| HOOD05162003217487 Unrestricted © Siemens Healthineers, 2021 MR Breast SIEMENS Healthineers Findings (1/2) In the breast findings, you can MR Breast A Q. + MR Breast Reading include more information about Distance to nipple chele 7.08 cm Learn the lesion, such as: Segments Dynamic Morphology 1 R Distance to skin Morphology 2 0.96 cm MC 1 ·Distance to chest ... • Distance to nipple Multiple time points Min / Max: 118.00 /309.00 Viewing Mean/SD: 225.36 /29.93 Area: 0.81 cm2 • Distance to chest wall • Distance to skin Findings A Breast Ratio (% Breast MR Breast 1 175 VVD Distance to chest wall 1.10 cm SP H9.9 Use the Distance Line tool to Distance to skin 0.96 cm 150 Distance to nipple 7.08 cm MC 1 0.81 c ... include the additional information. 125 100 75 Tools Synch Align Full Text Hide Hide Lines Reset Graphics Timepoi ... 25 Edit Snapshot Print Export Undo Redo Layout Image Image 0 50 100 150 200 250 300 350 400 450 500 Normal time (sec) 11:31 AM 5 Effective Date: 03 Sep 2021| HOOD05162003217487 Unrestricted © Siemens Healthineers, 2021 MR Breast SIEMENS Healthineers Findings (2/2) In the breast findings, a pictogram is MR Breast Ca + MR Breast Reading also available where you can place Single Learn Details Breast MR Breast 1 Current 5/22/2013 the red dot in the lesion location and Segment Type MR Breast Dynamic Attributes that are filled in automatically are indicated by E . Check include more detailed information that the attributes are correct. Morphology 1 Laterality right breast Morphology 2 Quadrant Upper outer quadrant of breast about the lesion, for example: Multiple time points Clock face Ten o'clock position Viewing Depth FGT BPE Level BPE Symmetry Lesion Type • Kinetic Curve Initial Mass Shape Mass Margin Findings Mass Internal Enhancement • Kinetic Curve Delayed Breast NME Distribution Ratio (%) Breast MR Breast 1 NME Internal Enhancement 175 MC 1 SP H9.9 Distance to chest wall 1.10 cm Kinetic Curve Initial Medium • Assessment Category Distance to skin 0.96 cm Kinetic Curve Delayed Plateau 150 Distance to nipple 7.08 cm Assessment Category MC 1 0.81 c ... Overall Rating 0 - Need additional imaging evaluation 125 1 - Negative Comment 2 - Benign finding Previous Finding Next 3 - Probably benign finding-short interval follow-up 100 All this information is included in the 4 4 - Suspicious abnormality, biopsy should be considered R 4A - Low suspicion 75 4B - Intermediate suspicion final report, which uses the Tools 4C - Moderate suspicion L 5 - Highly suggestive of malignancy, take appropriate action 50 6 - Known biopsy proven malignancy Synch Align Hide Hide Lines Rezet Graphics Timepoi ... BI-RADS® standard to classify the Post procedure mammograms for marker placement 25 Snapshot Print Export Undo O findings. Edit Layout Image Image 0 50 100 150 200 250 300 350 400 450 500 Normal time (sec) 11:44 AM 6 Effective Date: 03 Sep 2021| HOOD05162003217487 Unrestricted © Siemens Healthineers, 2021 MR Breast SIEMENS Healthineers Additional Configuration (1/2) You can perform a Motion Correction MR Breast + MR Breast Reading Motion Correction ? X in the dynamic breast sequence and Learn improve the accuracy of the Single Segments Settings MR Motion Correction Sett ... Config. Dynamic Input Volumes t1_f13d_tra_dynaVIEWS_spair_1+5.latest.Phase_02 t1_f13d_tra_dynaVIEWS_spair_1+5.latest.Phase 03 diagnostics. Morphology 1 t1_f13d_tra_dynaVIEWS_spair_1+5.latest.Phase_04 Morphology 2 Motion Correction (Elastic) Correction Tools t1_f13d_tra_dynaVIEWS_spair_1+5.latest.Phase_05 t1_f13d_tra_dynaVIEWS_spair_1+5.latest.Phase 06 Multiple time points 2D Distortion Correction ImageFilter Smooth Viewing Reverse 2D Distortion Correction Analysis Tools x - A new MoCo series will be created and 3D Distortion Correction Auto Windowing Reference Volume (1_f13d_tra_dynaVIEWS_spair_1+5.latest.Phas ... auto MR Color LUT Result Series Name MOCOHiQ_11_fl3d_tra_dynaVIEWS_spair_1+5 saved in your Series list. MR Presets Target Segment Reset Windowing Findings Breast OK Preview Cancel 4 %- R Tools L Synch Hide Hide Lines Reset Graphics Timepoi ... Edit Snapshot Print Export Undo Redo KU Image Image 1:56 AM 7 Effective Date: 03 Sep 2021| HOOD05162003217487 Unrestricted © Siemens Healthineers, 2021 MR Breast SIEMENS Healthineers Additional Configuration (2/2) In the Motion Correction window, you Motion Correction X MR Breast Q. + MR Breast Reading can configure your own preset and Settings MR Motion Correction Sett ... define the preprocessing step. Single Learn Input Volumes t1_f13d_tra_dynaVIEWS_spair_1+5.latest.Phase_02 Segments t1_f13d_tra_dynaVIEWS_spair_1+5.latest.Phase_03 t1_f13d_tra_dynaVIEWS_spair_1+5.latest.Phase 04 t1_f13d_tra_dynaVIEWS_spair_1+5.latest.Phase 05 Dynamic t1_f13d_tra_dynaVIEWS_spair_1+5.latest.Phase 06 Morphology Morphology 2 Remove After defining the preprocessing step, Multiple time points Reference Volume 1_f13d_tra_dynaVIEWS_spair_1+5.latest.Phas ... Viewing Result Series Name MoCoHiQ_t1_f13d_tra_dynaVIEWS_spair_1+5 MoCo series will be automatically 11 Target Segment Motion Correction Settings ? X created for the next studies. Settings Preprocessing Findings Breast MR Motion Correctio. Name of Settings MR Motion Correction Settings MR Motion Correctio. MR Motion Correctio. Reference Volume 2¢ Mode High Quality Fast R Tools Synch Align Full Text Hide Hide Lines Reset Graphics Timepoi ... + Edit Snapshot Export Undo Add Duplicate Delete Layout Print Image Image 12:00 PM OK Cancel 8 Effective Date: 03 Sep 2021| HOOD05162003217487 Unrestricted © Siemens Healthineers, 2021 SIEMENS Healthineers Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthcare GmbH 2021 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens-healthineers.com 9 Effective Date: 03 Sep 2021| HOOD05162003217487 Unrestricted © Siemens Healthineers, 2021
- syngo.via
- MR
- job aid
- JA
- MR Breast
- Breast