syngo.via MR Prostate Workflow Job Aid
This job aid provides information about new features and functionalities in the MR Prostate workflow with syngo.via.
SIEMENS Healthineers syngo.via MR Prostate Workflow Job Aid Template Effective Date: 27 May 2019 | HOOD05162003010284 Job Aid Effective Date: 26 Jul 2021| HOOD05162003211150 Unrestricted © Siemens Healthineers, 2021 syngo.via MR Prostate Workflow Job Aid SIEMENS Healthineers Table of Contents Overview 3 MR Prostate A Prostate Reading MR Prostate Reading 4 1,2 Learn Prostate Biopsy Support 5 Click Segments Support Lesions Prostat R Prostate Findings and Reporting 6 x Fi Findings Prostate MR Prostate 1 Gland Volume 65.57 ... Tools R .- L Synch Align Custom Hide Hide Lines Reset Graphics Timepoi ... LO Edit Snapshot Print Export Undo Redo KU Layout Image Image 2:25 PM MR Prostate workflow is part of the syngo.MR General Engine. 2 Effective Date: 26 Jul 2021| HOOD05162003211150 Unrestricted © Siemens Healthineers, 2021 MR Prostate Workflow Overview SIEMENS Healthineers The MR Prostate workflow supports optimal MR Prostate AL Q+ MR Prostate Reading reading and reporting of the prostate examination. The images are sorted and displayed in such a way Prostate Viewing MR Spectro Analysis that all relevant images of the same orientation MR Tissue4D Analysis are side by side and move synchronously when the Findings user scrolls through the images. Prostate Standard tools support the analyses and diagnosis of the prostate. Tools Lynch Align Custom Hide H Graphics Edit Snapshot Print Export Layout Image Image The findings use the latest PI-RADS prostate 2:31 P reporting guidelines. The location of the finding is added in a prostate pictogram, which is also part of the final report. The final report can be sent to PACS or to referring physicians. MR Prostate workflow is part of the syngo.MR General Engine. 3 Effective Date: 26 Jul 2021| HOOD05162003211150 Unrestricted © Siemens Healthineers, 2021 MR Prostate Workflow Reading SIEMENS Healthineers The MR Prostate workflow contains two default steps: Steps Layouts Standard tools Prostate and Viewing. MR Prostate Prostate Zoom/Pan Distance Line Q + MR Prostate Reading MTDF73_Greg Zoom and pan image [2]] ROI Freehand Private Layouts Rotate Pixel Lens Public Layouts Windowing Marker -IT chale Segments Support Arrow Several optional layouts can be selected from the Correlated Cursors Angle Movie Prostate Morph & Lesions Morph 3D Diff Text Layout Gallery. Scroll MC-PixelLens Prostate Save as Series Viewing MR Spectro Analysis O Morph & R A Flip Horizontal Diff & Dyn Morph & Diff & MR Tissue4D Analysis O Spectro Fit to Segment Standard tools are integrated and can be used for Correction Tools >> Advanced Close MPR/MPR mageFilter Smooth analysis of the images, for example, 3D reference THO Cinematic VRT Analysis Tools x + VRT point, distance line, mean curve, and 3D volume. Auto Windowing Biopsy Support auto MinIP Thin MR Color LUT Biopsy MIP Support MPR Thick MR Presets FIL/DIS2D 2D Reset Windowing Biopsy Support assists in planning and performing ultrasound guided biopsies. Optional functionality Prostate Viewing Optional functionality can be purchased which is MR Spectro Analysis MR Tissue4D Analysis embedded in the workflow, like Prostate Lesion* O detection, Tissue4D, or Spectroscopy. II MR Prostate workflow is part of the syngo.MR General Engine. 4 * The product is not commercially available in some countries, e.g., the US. Due to regulatory reasons, future availability cannot be guaranteed. Effective Date: 26 Jul 2021| HOOD05162003211150 Please contact your local Siemens Healthineers organization for further details. Unrestricted © Siemens Healthineers, 2021 MR Prostate Workflow Biopsy Support SIEMENS Healthineers With Prostate Biopsy Support, prostate segmentation is performed automatically. Biopsy Click the Biopsy Support icon in the Case Navigator. Support A new image layout opens. The segmentation of the prostate is Create Findings for Biopsy Planning automatically calculated from transversal T2-weighted TSE or SPACE series. IT VOI Sphere Freehand MR Marker Segmen Use the tools from the lower right segment to mark possible points of Export of Biopsy Support Results interest for biopsy planning. Reference Series t2_tse_tra_high res The lower right segment shows the currently selected reference series All Findings Gland Volume and the list of findings. To export the findings for biopsy planning, select the corresponding reference series and click the Save and Export button. Confirm the data Save Save and Export Close in the following Export Data dialog box. Click the Save button to save the findings in DICOM RTSS format with the current data set. MR Prostate workflow is part of the syngo.MR General Engine. 5 Effective Date: 26 Jul 2021| HOOD05162003211150 Unrestricted © Siemens Healthineers, 2021 MR Prostate Workflow Findings and Reporting SIEMENS Healthineers The findings include all types of standard Prostate Details Pelvis MR Prostate 1 Current 6/12/2017 Pelvis MR Prostate 1 Gland Volume 38.98 ... Type MR Prostate measurements used during the reading. Attributes that are filled in automatically are indicated by . Check that Seminal Vesicles the attributes are correct. R APS L 12 Region TZa Gland Volume 123 123 Laterality left The findings are pre-populated to the pictogram and Location Basal Base 12W the final report. The findings use the latest PI-RADS DWI 3 12: DCE prostate reporting guidelines. Tools EPE No Mid L PI-RADS 3 Synch Align Custon Hide Hide Lines Reset Index Lesion Distribute Insert Format Table Text Graphics Timepoi. Overall Rating MR PI-RADS 2 Report Comment Apex Marker Tools MR PI-RADS 2 Report Edit Snapshot Print Export Undo Redo ROY Cirde Layout Image Urethra Patient Demographics ‹ Previous Finding Next Finding > Name ( MR_Prostate_Lesions ] Patent ID ( Germany_MAC ) (mais ) Buth Date [ 1/1/1944] Prostate Biochemical Results Oland Volume (om") 34.08 oml PSA Density (ngini) R Seminal Vesicles Olobal PH-RADS Findings Information. 75% MR Prostate workflow is part of the syngo.MR General Engine. 6 Effective Date: 26 Jul 2021| HOOD05162003211150 Unrestricted © Siemens Healthineers, 2021 SIEMENS Healthineers Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthcare GmbH 2021 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens-healthineers.com 7 Effective Date: 26 Jul 2021| HOOD05162003211150 Unrestricted © Siemens Healthineers, 2021
- syngo.via
- MR
- job aid
- JA
- prostate
- mr prostate