syngo.via VA30 - CT Dual Energy Brain Hemorrhage
syngo.via VA30 - CT Dual Energy Brain Hemorrhage
syngo.via® CT Dual Energy Brain Hemorrhage The syngo.via Dual Energy Brain Hemorrhage application class extracts contrast medium (iodine) from DE brain CTA datasets. This provides an iodine distribution/ enhancement map of the brain parenchyma. The application helps differentiate new blood within a resolving hemorrhagic site. 1. From the Patient Worklist, load an appropriate data set into the Dual Energy Workflow. If the examination has been correctly mapped, double click to load If manual mapping is required, right-click the examination and select (Re-) Assign Workflow Template > CT Dual Energy 2. From the Workflow Steps, click on the Brain Hemorrhage Application Class. Head (CA) Appication Profile Head Bone Removal Brain Hemorrhage Resolution lodine Rabo MM Reading 3. syngo.via will apply a colored overlay map to the MPR images in Segments 1, 2, and 3, and will also generate a mixed DE image in Segment 4 (depending on selected layout). The overlay images display the iodine enhancement in the mixed image in Hounsfield units. SIEMENS www.usa.siemens.com/healthcare 642 Effective date: 9/8/2016 Page 1 of 3 4. Hover over the bottom center of a Dual Energy overlay image to access the Mixing Ratio mini-toolbar. The slider allows you to control the composition of the displayed fused images. Depending on the slider position, either more CT data or more overlay data is displayed. Move the slider to the left to display more CT image data with the colored overlay (iodine enhancement) removed. This is a DE virtual non-contrast image of the contrast-enhanced source images. This image may be windowed using the middle mouse button over the right half of the image segment. Move the slider to the right to display more iodine data in the image. H H FL_DE_Carotid_Gliomic_Tumor, Portugal Ref.: Dual Energy Onco+Vascular Gold FL_DE_Carotid_Gliomic_Tumor, Portugal Ref.: Dual Energy Onco+Vascular Gold SOMATOM Definition Flash SOMATOM Definition Flash -- > CURRENT.NATIVE.BRAIN WORKINGSE CT 2009A -- > CURRENT.NATIVE.BRAIN WORKINGSE CT 2009A # 201 2R0986 # 2012R0986 4/1 4/2010 4/1 4/2010 4:47:30.20 PM 4:47:30.20 PM 19 FRM 1 22 FRM 1 SP L3.0 / SP L3.0 SPL8:3 / SP-L8:3 5cm o 50.00% 0 0.00% Manip MPR FUSION SL min Manip MPR FUSION SL min DE VNC/CON DE VNC/CON +C CT Mixing Ratio Overlay 500 CT Mixing Ratio Overlay 500 150 250 +C 250 50% 50% 100% 0% FL_DE_Carotid_Gliomic_Tumor, Portugal Ref.: Jal Energy Onco+Vascular Gold SOMATOM Definition Flash -- > CURRENT.NATIVE.BRAIN WORKINGSE" CT 2009A # 2012R0986 4/1 4/2010 4:47:30.20 PM 22 FRM 1 SP-L8:3 / SPL8:3 5cm Manip MPR FUSION o 100.00% DE VNC/CON SL min CT Mixing Ratio Overlay 600 W 500 +C 150 C 250 -- 0% 100% SIEMENS www.usa.siemens.com/healthcare Page 2 of 3 5. In this clinical example, the color overlay image shows an area of hyper-dense iodine concentration within the existing hematoma, possibly indicating a new bleed within the old hematoma bed. 6. This resulting VNC data set may be saved as a new axial, coronal or sagittal series using the Parallel Ranges tool in an upper left colored overlay segment. SIEMENS www.usa.siemens.com/healthcare Page 3 of 3
- syngo.via VA30 - CT Dual Energy Brain Hemorrhage