syngo.via VA30 - CT Neuro DSA Aneurysm Segmentation

syngo.via VA30 - CT Neuro DSA Aneurysm Segmentation

syngo.via® CT Neuro DSA – Aneurysm Segmentation The Aneurysm Segmentation tool in syngo.via CT Neuro DSA allows for quick evaluation of potential lesions in VRT or MIP result images. 1. From the upper left hand corner in-segment tools, select Aneurysm Segmentation. Punch Clip Plane Clip Box Radial Ranges Aneurysm Segmentation 2. In a VRT, MIP, or MPR result image, click on a point of interest. ............... . .. .... ........................ . .. ..................... H 1 .......... AS+ NeuroDSA_Carotids_Aneurysm, NYU_USA 2012R0480 Ref.: Neurovascular Gold *9/27/2011, 0 Definition AS+ # 2012R0480 CT 2010B 8/1 0/2011 1:45:05.23 PM SP A172.0 R Ocm CQ! A VRT SIEMENS www.usa.siemens.com/healthcare 644 Effective date 9/8/2016 Page 1 of 2 3. The aneurysm is detected, segmented, and zoomed in together with the adjacent vessels. You can repeat this step to segment other structures. H AS+ NeuroDSA_Carotids_Aneurysm, NYU_USA 2012R0480 Ref.: Neurovascular Gold *9/27/2011, 0 Definition AS+ # 2012R0480 CT 2010B 8/1 0/2011 1:45:05.23 PM SP A174.0 R 1 cm CQ ! A Manip VRT ............................................................................................................................................................................................................................. 4. Check all detected aneurysms in the CTA data set. 5. From the upper left hand corner in-segment tools, choose Aneurysm Segmentation again to get back to the full 3D view. SIEMENS www.usa.siemens.com/healthcare Page 2 of 2