syngo.via VA30 - Rapid Results Configurator
syngo.via VA30 - Rapid Results Configurator
syngo.via® Rapid Results Configurator Radid Results Technology allows for the creation of workflow-specific protocols that automate post-processing steps and interactions, like creating bookmarks or parallel ranges. Rapid Results can reduce the time needed to document cases and can improve reproducibility among users. 1. From the Rapid Results workflow step, open the wrench icon to access the Protocol Configurator. Rapid Results Protocols Vascular Overview Step 1/14 Select Layout 2. Click New. In the Protocols field, enter a name for the new protocol and press Return. Protocol Configurator ? X Protocols NEW PROTOCOL NAME Rename Copy Delete Current Protocol AVEHEUTE STEPS Select Layout System Actions User Actions Step Properties Step Name Select Layout Monitor Configuration SingleWideScreen Layout Name Single CPR Minimize Apply Close Cancel SIEMENS www.usa.siemens.com/healthcare 646 Effective date 9/8/2016 Page 1 of 3 3. By default, the Select Layout step is inserted into the new protocol. Select the desired layout from the drop down list. Protocol Configurator ? X Protocols NEW PROTOCOL NAME New Rename Copy Delete Current Protocol Available Steps Select Layout System Actions User Actions Step Properties Step Name Select Layout Monitor Configuration SingleWideScreen Layout Name Single CPR Twin CPR VRT Long CPR Single CPR 3 CPR Minimize Carotid 2 CPR Runoff 2 CPR Apply Close Cancel Runoff Runoff Twin CPR VRT 3 CPR Classic 4. In the image area, select the segment that you would like to configure. 5. In the Protocol Configurator window, double-click a step from the Available Steps list to add it to the Current Protocol list, or use the Add Step arrow. Adjust the Step Properties if applicable. Some steps – like Parallel and Radial Ranges – require that you first open the tool in the selected segment and configure the desired settings there. You can then add the step to the Current Protocol list. The parameters will be automatically copied into the Step Properties of the Configurator. Protocol Configurator ? X Protocols NEW PROTOCOL NAME New Rename Copy Delete Current Protocol Available Steps Select Layout Create Snapshot Bookmark Segment (MPR) Create Parallel Ranges Creale Parallel Ranges Create Radial Ranges Navigation Visualization Printing User Actions Step Properties Show Guidance Dialog Step Name Create Parallel Ranges Description Display Type MPR_THICK Image Thickness 3.0 Distance between Images 3.0 Number of Images 35 Minimize Apply Close Cancel SIEMENS www.usa.siemens.com/healthcare Page 2 of 3 6. To allow user interaction, add a Pause Step from the Available Steps list. Customized instructions for this step can be entered by selecting Show Guidance Dialog and entering the desired text in the Description box. Protocol Configurator ? X Protocols NEW PROTOCOL NAME New Rename Copy Delete Current Protocol Available Steps Select Layout Create Parallel Ranges Bookmark Segment (MPR) Create Radial Ranges Create Parallel Ranges Navigation Il Pause Visualization Printing User Actions 11 Pause Step Properties Show Guidance Dialog Step Name Pause Description Please enter guidance text here. Minimize Apply Close Cancel 7. Add additional steps as necessary. Remember to select the corresponding segment in the image area before adding a new step. Steps can also be deleted if necessary by using the Remove Step icon. 8. Click Apply and Close to save the new Rapid Results Protocol. SIEMENS www.usa.siemens.com/healthcare Page 3 of 3
- syngo.via VA30 - Rapid Results Configurator