PEPconnect

syngo.via VB30-VB50 Delta Job Aid

This delta job aid is for users who skipped software versions and provides information about features and functionalities that came up between the software versions VB30-VB50 in syngo.via. 

SIEMENS Healthineers syngo.via VB30-VB50 News and Improvements Version 2021 Template Effective Date: 05/27/2019 | HOOD05162003010284 Job Aid Effective Date: 04/30/2021 | HOOD05162003188728 Unrestricted © Siemens Healthineers, 2021 syngo.via VB30-VB50 News & Improvements SIEMENS Healthineers Table of Contents General Improvements 3 MM Reading: Interactive Spectral Imaging 8 Clinical Tools in MM Reading 13 Findings Assistant in MM Reading 21 2 Effective Date: 04/30/2021 | HOOD05162003188728 Unrestricted © Siemens Healthineers, 2021 SIEMENS Healthineers News & Improvements General Improvements 3 Effective Date: 04/30/2021 | HOOD05162003188728 Unrestricted © Siemens Healthineers, 2021 syngo.via VB30-VB50 News & Improvements SIEMENS Healthineers General Improvements New design of user interface What’s new syngo News Siemens Healthineers now provides a new Automatic information window syngo News is our new information clear and easy digital interface throughout displaying information on what is new in channel specifically tailored to your unique all the new Siemens Healthineers products this version. needs. and service portfolios. SIEMENS Hecithineers SIEMENS New in this version Healthineers ? x Patient Browser Meet (12) Q Results (254 mon, 13:8:30) Series 25.39648 2507 2000 CT Lung Assistant* 2575646 yngo News 2575648 26:27 2000 In MM Reading 36/3 2300 CT Lung Assistant Similar Patient Search provides 24.20 2000 25.25648 In MM Reading 2535648 2610 2000. any time access to 26:07 2000 Similar Paliont Search provides any time access to 7509648 similiar reference cases · Similar references cases 24,00 2000 1623 2000 differential diagnosis textbook information Mom Differential diagnosis 25.35648 26.09.2000 Thieme eftef for imerstitan 2535645 26.10 2000 2836446 26:01 2900 25-39546 Ling dise mes . Textbook information from Help 2539648 26:07 2000 26.07 2000 Thieme eRef 24 40 2000 Remote Assistance 2339648 36X7 2000 21.00 2200 for interstitial lung diseases What's New 0Y6 09 7858 syngo News CI Therm C. 14 24 1541 2000 1044 02.12:19863 O O O About EPHE syngo News PO CHET A FED CHESTAN Similar Patient Search Close PLLVS N TU Z diagnostic support 4 Effective Date: 04/30/2021 | HOOD05162003188728 Unrestricted © Siemens Healthineers, 2021 syngo.via VB30-VB50 News & Improvements SIEMENS Healthineers General Improvements – Printing • A new badge icon was implemented in order to indicate that images were sent to printing. Printing o X Print Printer Adobe PDF Copies 1 - • As soon as you print or delete the images, the T Layout Print aper Size Letter Number of Print-o ... 0 Gallery Save mage badge icon disappears. Zoom Pan Rearrange Text Keep Images Every N -. Invert Background Printer Microsoft XPS Doc • The Invert Background feature inverts the Paper Size Letter background of the printed segment on the film Copies print sheet. It does not invert the image itself. Print Save Image Number of Print-outs: 0 • When many print sheets are available, the Number Invert Background of images on last page is now displayed. 319 images on last page OPrinting syngo.via software version VB50 is not commercially available in all countries. 5 Due to regulatory reasons its future availability cannot be guaranteed. Effective Date: 04/30/2021 | HOOD05162003188728 Unrestricted © Siemens Healthineers, 2021 syngo.via VB30-VB50 News & Improvements SIEMENS Healthineers General Improvements – syngo.via OpenApps1 Digital Marketplace • Siemens Healthineers introduces the Digital Marketplace as the new web store X providing medical post-processing apps created by us or our partners. • Our Digital Marketplace provides both cloud based applications, as well as locally installed applications. OpenApps 2 X SIEMENS Share Germany (England . Login / Register Healthingers Locally installed applications, known as syngo.via Open Apps, are downloaded from Catalog Order statin • the digital marketplace and installed on your syngo.via server. Welcome to the Store Browse all digital offerings from the Sieme neers Diged Bcomptem Installed Apps Applicanot tutily The Installed Apps section provides further details on the installation date and All manufacturers AE tices syngo.via • Search for app name, hayword license state. Caas CAAS Workstation CAAS MR Solutions mediCAD" Classic • Each third party vendor application is downloaded with a demo dataset. Card ac Magnetic Feiorance [OUR) Othepedia argen Rang th(" is a tord rovescia port • Start the apps directly from this section for demonstration and training. fica degroot ins four tety sieps poocutting software for viewing and Digital Marketplace Q 3mensio Vascular Smensio Structural Heart Materialise Mimics inPrint SyMRI Neuro • The downloaded syngo.via OpenApps are seamlessly integrated in MM Reading, easily accessible via the corresponding icon in the tool gallery. OpenApps Installed apps can be directly started from this section for demo purposes mensio 3mensio Structural Heart Installation Date License State: Trial (1 User) 9.1 3/14/2019 Expires: 6/12/2019 (90 days left) Open Installed Apps 1 – Siemens Healthineers is neither the provider nor reseller nor legal manufacturer of any partner applications. Any claims made for 6 these products are under the sole responsibility of the legal manufacturer. Additionally, the partner applications mentioned here may Effective Date: 04/30/2021 | HOOD05162003188728 not be commercially available in all countries. Please contact the legal manufacturer for more information. Unrestricted © Siemens Healthineers, 2021 syngo.via VB30-VB50 News & Improvements SIEMENS Healthineers General Improvements – syngo.via OpenApps1 • Powered by the OpenApps Connector, you can now install the X desired application without internet connection in the syngo.via client, using any other windows computer in the same network with internet connection. 5 OpenApps × - 0 × + 1 Not secure syngovia/OpenApps/ ... • PACS Ready technology enables the auto-processing for OpenApps Applications. It can be run independently from any Start OpenApps Connector Use this button to start the OpenApps Connector tool which connects your system with the Siemens Healthineers Digital Marketplace. workflow configuration when new studies of the current day are incoming from the modality. • A badge icon notification will be displayed in the Digital - Marketplace shopping card icon when, for example, there are Welcome to the Store completely new apps available/published in the marketplace or -- your commercial/purchased license will expire soon. ---- --- --- - OpenApps.Connec .... exe Show all X 1 – Siemens Healthineers is neither the provider nor reseller nor legal manufacturer of any partner applications. Any claims made for these products are under the sole responsibility of the legal manufacturer. Additionally, the partner applications mentioned here may not be commercially available in all countries. Please contact the legal manufacturer for more information. 7 syngo.via software version VB50 is not commercially available in all countries. Due to regulatory reasons its future availability cannot be guaranteed. Effective Date: 04/30/2021 | HOOD05162003188728 Unrestricted © Siemens Healthineers, 2021 SIEMENS Healthineers News & Improvements MM Reading: Interactive Spectral Imaging 8 Effective Date: 04/30/2021 | HOOD05162003188728 Unrestricted © Siemens Healthineers, 2021 Interactive Spectral Imaging in MM Reading SIEMENS Healthineers A New Image Format for DE – SPP1 (Spectral Post-Processing) Spectral Post-Processing (SPP dataformat) • The Interactive Spectral Imaging features uses a single post processing series in the file format Spectral Post-Processing (SPP) that contains all the necessary information. Thus separate high and low kV datasets are no longer needed. • Improve your clinical workflow by bundling the spectral low and high kV series into one Spectral Post-Processing data series. Conventional CT • Interactive Spectral Imaging gives you the possibility to interactively change different monoenergetic energy levels and evaluate certain dual energy representations such as Virtual Non-Contrast (VNC) or Iodine in MM Reading. • The SPP series shows a conventional CT Image or a generated Monoenergetic Plus Image, readable in your PACS system. VNC 9 Effective Date: 04/30/2021 | HOOD05162003188728 1 – Functionality is provided by syngo.CT Dual Energy and syngo.CT Extended Functionality Unrestricted © Siemens Healthineers, 2021 Dual Energy goes Routine with syngo.via VB40 SIEMENS Healthineers Interactive Spectral Imaging – as Easy as Windowing Interactive Spectral Imaging (ISI) is a new and simplified way of visualizing Dual Energy data. Healthineers Server. MS-CT.APPVIA03.wurmlechalemera.de adminUser Viewing CT general Viewing • Instead of calculating multiple series like VNC or Mono+, Stack 3x2 MPR VRT Stack 2-2 Results 22 syngo.via now creates a single series called Spectral Post- Mono+ VNC Favorite Tools Processing (SPP) data that contains all the necessary post processing information. Series • Only these Spectral Post-Processing (SPP) data needs to be loaded to MM Reading in order to have access to the new Favorite Tools % Reset Rotate Synch Layout features and functionalities. Iodine Mixed sQuipu! Assisted: Distance ROI Circle Perpend ... Line Snapshot • On patient follow up, high and low kV data is no longer Bupulld needed. + 10 Effective Date: 04/30/2021 | HOOD05162003188728 Unrestricted © Siemens Healthineers, 2021 MM Reading SIEMENS Healthineers Interactive Spectral Imaging • Switch the most common Dual Energy application classes by one button click using the interactive image text: Server MSGTAPPVLAG3.munleon sievers.de . adminUser Mono+ Viewing • CT general Viewing Results • Virtual Non Contrast (VNC)1 Stack 3x2 MPR VRT Stack 2:22 22 Mono+ VNC Favorite Tools • Mixed • Iodine1 Series • Easily change the keV level of your Monoenergetic Plus image by: Favorite Tools Reset Rotate Synch • Mouse movement (left / right or up / down) Layout Iodine Mixed Assisted Distance ROI Circle • Entering a value using the keyboard Snapshot Export Full Text Hide Lines • Using the slider in the Dual Energy Mono Plus properties box Bupund > x auto Bone Vestels Remo Mono+ Dual Energy Mono+ Properties keV 70 70keV OK Cancel 1 – VNC and Iodine representations are not available for Dual Spiral Dual Energy and TwinSpiral Dual Energy 11 Effective Date: 04/30/2021 | HOOD05162003188728 Unrestricted © Siemens Healthineers, 2021 syngo.via VB30-VB50 SY News & Improvements SIEMENS Healthineers MM Reading: Interactive Spectral Imaging • ROI or VOI measurements can be performed on any representation [1] ROI Circle [1] ROI Circle Min / Max: 45 HU/282 HU Mono+ 70keV Mean/SD: 80 HU/19 HU Min / Max: 45 HU/282 HU Area: 1,96 cm2 Mean/SD: 80 HU/19 HU Area: 1,96 cm2 • ROI Measurement Details are explicitly informing you on which representation the measurement was performed • The Findings Assistant reflects as well on which representation the measurement has been performed • Spectral Post-Processing (SPP) data can also be used with CT Extended Functionality in MM Reading such as: Mono+ 70keV VNC • Define vessel • Table- and Bone Removal Define Remove Bone Heart Isolation Vessels Table Remo • • Coronary Tree View • cPR Ranges Isolate Coronary Heart Tree 12 Effective Date: 04/30/2021 | HOOD05162003188728 Unrestricted © Siemens Healthineers, 2021 SIEMENS Healthineers News & Improvements Clinical Tools in MM Reading 13 Effective Date: 04/30/2021 | HOOD05162003188728 Unrestricted © Siemens Healthineers, 2021 syngo.via VB30-VB50 SY News & Improvements SIEMENS Healthineers MM Reading: Clinical Tools – General Tools • MR General Tools previously only available in MR ... .. workflows are now also available in MM Reading in the toolbox or lower right corner menu --- • Access the following Analysis tools: • Subtraction • Addition • Division ADC / calculated b- • Multiplication Substraction Composer • Arithmetic Mean and values • Calculated ADC and B-values Simplify routine All necessary MRI Accessible with one reading Generic tools click As well as to the Correction tools such as: • Motion Correction • Distortion correction and • Image Filter functions • Composing and combining is integrated as well 14 Effective Date: 04/30/2021 | HOOD05162003188728 Unrestricted © Siemens Healthineers, 2021 syngo.via VB30-VB50 SY News & Improvements SIEMENS Healthineers MM Reading: Clinical Tools – CT Lung Change Tool In MM Reading, the CT Lung Change tool displays changes in density across different time points. CT Lung Change ? X Compare following Series 10/6/2014 -Lung 1.0 17OF 3 LCAD [3] • Current and prior series are automatically registered. &/19/2014 -Lung 1.0 17Of 3 LCAD [3] 8/19/2014 -Lung 1.0 17Of 3LCAD [3] 6/10/2014 -Lung 1.0. 170f 3 LCAD [3] • If the automatically selected series from the prior time point is not adequate, you can Show Restrict to Lung Hide Evalots Change select another suitable series from the drop-down menu. Density: CT Lung Change ? X • Changes in HU values are displayed as a colour overlay on MPR/ MPR Thick: Decreased Compare following Series • Decreased HU values are indicated by blue colour. 10/6/2014 -Lung 1.0 17of 3 LCAD [3] • Increased HU values are indicated by orange colour. X Lung Change for 6/10/2014 -Lung 1.0 170f 3 ... • The evaluate change functionality activates a lens, displaying original series without Showl Evaluate M Restrict to Lung colour overlay. The toggle functionality allows to change the time point visualized in Hide Change the lens to evaluate a dedicated region. .................. ... ... .. The CT Lung Change tool can be The CT Lung Change tool can be • A progress bar is displayed to provide feedback on how long the comparison will CT Lung take. Change invoked from the tool gallery. invoked from the tool gallery. ... 15 Effective Date: 04/30/2021 | HOOD05162003188728 Unrestricted © Siemens Healthineers, 2021 syngo.via VB30-VB50 SY News & Improvements SIEMENS Healthineers MM Reading: Clinical Tools – LungCAD1 Improved In MM Reading, the LungCAD functionality is enhanced with a new algorithm and a new Navigation Tool. • The CAD markers are automatically segmented and quantified (Diameter, Max Orthogonal diameter, Mean diameter, Volume, Average HU). • A mini toolbar has been introduced to navigate through the LungCAD marks. The lens view provides: CAD3 • • A zoomed view of the CAD marks. Diameter: 15.45 mm Max. Orth. Diam: 12.04 mm • Different windowing levels to enhance distinction between nodule Mean Diameter: 13.74 mm Volume: 1.21 ml components. Average HU: 6.25 HU B • All accepted LungCAD marks are listed as findings in the Findings Assistant L automatically. S 3/15 ........................................ The LungCAD tool can be LungCAD invoked from the tool gallery. .. 1 – LungCAD requires an additional license and might not be available in all countries, functionality might vary in different countries. 16 Effective Date: 04/30/2021 | HOOD05162003188728 Unrestricted © Siemens Healthineers, 2021 syngo.via VB30-VB50 SY News & Improvements SIEMENS Healthineers MM Reading: Clinical Tools – Lesion Quantification Tool • In addition to the automatic lesion quantification available in the LungCAD tool, a new semi-automatic 3D segmentation tool for the Favorite Tools × quantification of lung nodules in CT datasets has been implemented in MM Reading. Scroll Rotate Synch Open Apps Hide Graphics • The Lesion Quantification tool is located in the tool gallery. ? • This tool uses the same algorithm as in MM Oncology CT Lung Quick Distance ROI Auto Full Text Auto Segmentation tools. Guide Line Contour Views • It can be used to measure solid and sub-solid lung nodules. Spine CT Lung Lesion LungCAD CT Lung Ranges Change Quantific Assistant 17 Effective Date: 04/30/2021 | HOOD05162003188728 Unrestricted © Siemens Healthineers, 2021 syngo.via VB30-VB50 SY News & Improvements SIEMENS Healthineers MM Reading: Clinical Tools – CT Lung Assistant (Similar Patient Search1 ) CT Lung Assistant - Doe, John (01-Jan-00) • The CT Lung Assistant tool which calls-up the SPS Web Service is available in the MM SIEMENS Similar Patient Search Web Service Favorite Tools × Healthineers Reading workflow. Pulmonary Alveolar Proteinosis Scroll Rotate Synch Open Apps Hide Graphics • The Similar Patient Search (SPS) Web Service is an interactive tool that provides Pneumocystis Jirovecii Pneumonia (PJP) Quick Distance ROI Auto Full Text Auto supplementary information to a radiologist Guide Line Contour Views reading chest CT images. Spine CT Lung Lesion LungCAD CT Lung Interstitial Pneumonia and Atypical Pneumonia Ranges Change Quantific Assistant • It presents visually similar reference cases with known diagnosis from a cloud database and in addition, relevant textbook content from Cryptogenic Organising Pneumonia (COP) Thieme, a renowned scientific publisher . • You need to have an internet connection on O Caution: The displayed reference cases are suggestions. The final dagnosis shall only be made based on your clinical knowledge. the syngo.via client to be able to use this feature. 1 – SPS is not available in all the countries due to regulatory reasons. Future availability cannot be guaranteed. 18 Effective Date: 04/30/2021 | HOOD05162003188728 Unrestricted © Siemens Healthineers, 2021 syngo.via VB30-VB50 SY News & Improvements SIEMENS Healthineers MM Reading: Clinical Tools – Spine Ranges – Correct the Centerline The spine ranges are always created perpendicular to SIEMENS x Healthineers SI_CT_Lung_Onco, 105 KG 160. . 1/1/1958 F 201880001 a center line that runs along the spinal cord. Viewing CI general Viewing MIR VET Stock 2x2 If this is incorrect you can now correct the center line Favorite Tools using the green circles that are displayed in the RH center of the vertebras. TOO Series The correction can be performed in: Coronal plane Parallel ) Radial Curved = spine * Vascular • Favorite Tools sou put • Axial plane Image Thickness 2.0 mm Distance between Images 2.0 mwm • Sagittal plane Open Apps Number of images 164 + Guide Field of View 158.5 = x 158.5 mm Distance NOI Orde Presets Image Series Bupuy RH After the correction you need to press Start to get Snaptheit the results. This ranges tool can be used on CT images. Start Accept Clase 5:15 PM 19 Effective Date: 04/30/2021 | HOOD05162003188728 Unrestricted © Siemens Healthineers, 2021 syngo.via VB30-VB50 SY News & Improvements SIEMENS Healthineers MM Reading: Clinical Tools – ROI Auto Contour • The ROI Auto Contour enables you to measure a lesion A ROI Properties Distance Line ? X with the assistance of auto contouring and can be used ROI Auto Contour with any modality that supports a ROI measurement. Display the following evaluations: Pixel Lens /Min/Max Arrow Mean/SD Marker • It is available in the top right corner menu at same M Area (cm2) Angle Sum position as the ROI Polygonal was in the tool gallery or Number of Pixels T R Text Enhancements: alternatively can be added in the context menu or Spine/Rib Label *** Automatic Contour in Polygonal ROI Favorite Tools window. OK Cancel • Using the RMB, open the ROI Properties and make sure Favorite Tools X the checkbox Automatic Contour in Polygonal ROI is ? 1 selected. Scroll Rotate Synch 3D Ref. Open Apps Point Quick Guide • This functionality is available for 2D, MPR, MPR Thick, Distance ROI Auto Parallel Snapshot Print Export Line Contour Ranges Image Image MIP Thin, MinIP Thin, and MPR/MPR images. E 1 Full Text Hide Lines Spine/Rib Reset Assisted Auto r Label Layout Perpendi ... Views Lesion LungCAD CT Lung CT Lung Define Quantific ... Assistant Change Vessels 20 Effective Date: 04/30/2021 | HOOD05162003188728 Unrestricted © Siemens Healthineers, 2021 SIEMENS Healthineers News & Improvements Findings Assistant in MM Reading 21 Effective Date: 04/30/2021 | HOOD05162003188728 Unrestricted © Siemens Healthineers, 2021 syngo.via VB30-VB50 SY News & Improvements SIEMENS Healthineers MM Reading: Findings Assistant – Body Regions & Reporting Guidelines The Findings Assistant supports the creation and management of structured findings. Findings × It is available in MM Reading and all MR workflows, except MR Cardiac. Lung Details LungRADS Screening 2 Current LungRADS Screening 2 max nodule length 0,99 cm Type LungRADS Screening orth. nodule length 0,78 cm lower lobe of left lung,low 1010 • Cluster findings now according to body regions or organs and add general Max Solid Compo ... Dista Location Orth. Solid Comp ... Dista Organ Segment 10 Posterior basal, 10 Pos information. Series/ImaNo Clinical Finding Nodule Solidness Descrip .. solid Endobronchial les ... no • New reporting guidelines enhance documentation and communication of results: Fatty no In addition to PI-RADS and BI-RADS, further international guidelines for: Basic spiculated no no • Lung-RADS Screening Cad-Stenosis calcification Cad-Stenosis Finding Group Margin Smooth LI-RADS growth • Lung Cancer TNM Staging baseline Lung Cancer Primary Tumor Additional pathology no • LI-RADS Lung cancer Group Mean Total (mm) 9,00 ¢ Lung cancer distant metastasis CAD-RADS Mean Solid (mm) E 0,00 • Lung cancer lymph nodes Lung-RADS as Lung-RADS 4A are now available. Lung cancer pulmonary nodules LungRADS Screening Disclaimer ACR Lung-RADSTM Versic MR Breast MR Prostate Overall Rating Comment • Measurements and other attributes can now directly be exported from Findings Neuro3D Neurology Assistant1 Pulmonary nodule PDF Previous Finding Next Finding . 1 – Export includes patient demographics, body part and finding information. Export to email is only available if Microsoft Outlook account is 22 configured on the syngo.via client. Effective Date: 04/30/2021 | HOOD05162003188728 Unrestricted © Siemens Healthineers, 2021 SIEMENS Healthineers Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2021 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers 23 Effective Date: 04/30/2021 | HOOD05162003188728 Unrestricted © Siemens Healthineers, 2021

  • syngo.via
  • SY
  • delta job aid
  • vb30-vb50
  • VB30-VB50