syngo.via View&GO: How to Create Ranges
This job aid will guide the user through creating ranges on the workstation
syngo.via View&GO: How to Create Ranges XPRF Ranges are tools that allow the user to create a new set of images through a specific region of interest for evaluation and/or archiving purposes. The Ranges tools are available in the top left corner menu of an image segment and in the Tool Gallery. • Parallel Ranges – define parallel slices of a volume for reconstruction. • Radial Ranges – define radial views of a volume (anatomy) for reconstruction. • Radial Sliced Ranges – define slices of a volume for reconstruction that are arranged around a pivot. • Curved Ranges – define curved slices of a volume for reconstruction. • Spine Ranges (optional) – define slices perpendicular to the spinal cord. • Vascular Ranges (only available with the CT Vessel extension) – create series of images around or along the CPR. How to Create Ranges Step by Step 1. From the top left corner menu, hover over Ranges > Parallel Ranges (desired type of range) – or – Select the Parallel Ranges (desired range type) icon in the Tool Gallery. Zoom/Pan A 3D Reference Point1 4.61999 Hospital SOMATOM Force VA50A ֏ Windowing HFS Tool Gallery Il Movie Marker Arrow Text Rotate 1 Ranges Scroll Ranges 1 Parallel Ranges Parallel Radial Radial Curved Spine Vascular Ranges Ranges Slice ... Ranges Ranges Ranges Save as Series - Radial Sliced Ranges. Fit to Segment Radial Ranges 5cm Image Visualization R : A Flip Horizontal Curved Ranges Fit to Fit to Acq. Segment Hide Hide Lines Full Text GT 0.0 Lock Ref = Spine Ranges Size SL 1.0/1 92x0.6/p0.6 Graphics Lines 176 1/0 335 Br40.d3n * Vascular Ranges 55 Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/11/2019 | HOOD05162002998095 Healthineers Job Aid Effective Date: 8/25/2020 | HOOD05162003114147 Job Aid | How to Create Ranges Effective Date: 8/25/2020 | HOOD05162003114147 The screen layout changes to the Ranges layout including the ranges control segment, in which you can adjust ranges parameters manually. Healthingers Syngo2 Multitom RAX 3D 01/01/1900 M 01011900 Viewing Series Multitom RAX 3D Multitom RAX 30 Multitom RAX 3D Viewing 01011900 01011800 01011900 Lack 3x2 Stack Aut Foppele CURRENT CURRENT CURRENT 30 nG fix T_Fact_HD_16 sharp 2 30 nG fix T_Foot_HD_16 sharp 2 30 nG foc T_Foot_HD_16 sharp 2 Current 1.2 MPR VRT MPR MIP MPR XA Unknown study description Favorite Tools R T Foot HD _1 ... ........... 10cm 10cm 477 476 Series Parallel Radial Curved Multitom RAX 3D Favorite Tools Preview 01011900 CURRENT Preset Select the Preset 3D nG fix T_Foot HD_16 sharp 2 Distance ROI Circle Image Thickness 0,5 mm Line 2 Distance between Images 0,5 Printing mm Snapsho Image O 2000 Number of Images 205 Field of View 204,8 x 204,8 mm Presets Orientation Image Series Complete Complete Complete Start Accept Close 08:07 2. Adjust the desired range coverage by dragging the range handles in the reference segment (2a) and the lateral view segment (2b). Verify the range selection in the lower left Preview segment (2c). Healthineers> Syngo2 - S Multitom RAX 3D * 01/01/1900 M 01011900 Viewing HAR AFR Series X Multitom RAX 30 Multitom RAX 3D Multitom RAX 3D Viewing Mack 3x2 Stack Aut Follow CURRENT 01011900 01011900 CURRENT CURRENT 30 nG fix T_Foot_HD_16 sharp 2 3D nG fix T_Foct_HD_16 sharp 2 Current MPR VRT MPR MIP MPR XA Unknown study description RPH Favorite Tools 2a 2b 30 nG fix T Foot_HD_1 ... 0cm 10cm 10cm Series Parallel Radial Curved Favorite Tools Multitom RAX 30 Preview 01011900 CURRENT Preset Select the Preset 30 nG fix T_Foot_HD_16 sharp 2 2c Distance ROI Circle 2 Image Thickness 0,5 mm Line Distance between Images 0,5 mm Printing Snapshot Export Number of Images 205 Image Field of View 204,8 = x 204,8 mm Paralel Ranges Presets Orientation Image Series Complete Complete Completo 716 Start Accept Close 08:12 Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Page 2 of 8 Job Aid | How to Create Ranges Effective Date: 8/25/2020 | HOOD05162003114147 3. Ranges can also be created by selecting the predefined anatomical range presets from the Presets list. Presets are grouped by body region examined and may be modified after selecting the preset if desired. Parallel O Radial Curved Spine * Vascular Preset Select the Preset Image Thickness 0.3 mm Distance between Images 0.3 mm 3 Number of Images 256 - Field of View 176.0 X 176.0 + mm Presets Orientation Image Serie Complete Complete Complete cresce Coronal Axial Sagittal Preset Start Accept Close 4. The following can be defined by selecting the values offered or by entering specific values in the ranges control segment: • Image Thickness – depends on the physician, common is between 3 to 5mm. • Distance between Images – should be equal to or less than the Image Thickness (in mm) to ensure there is adequate overlap when postprocessing. • Number of Images Parallel Radial Curved Spine * Vascular Preset Select the Preset Image Thickness 0.3 Y mm Distance between Images 0.3 mm 4 Number of Images 256 Field of View 176.0 + x 176.0 + mm Presets Orientation Image Series Complete Complete Axial Create Coronal Preset Start Accept Close Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Page 3 of 8 Job Aid | How to Create Ranges Effective Date: 8/25/2020 | HOOD05162003114147 5. Field Of View (FOV) – To adjust drag the green frame in the FOV segment (5a) or enter specific values in the ranges control segment (5b). 6. Healthineers Syngo2 Multitom RAX 3D 01/01/1900 M 01011900 Viewing Series Multitom RAX 30 Multitom RAX 3D Multitom RAX 3D 01011900 01011900 1011900 Viewing Stack 3x2 Stack 4x4 Follow Up CURRENT CURRENT CURRENT 2TP 202 30 nG fix T_ Foot_HD_16 sharp/2 30 nG fix T_Foot_HD_16 sharp 2 5a DniG fix T_Foct_HD_16 sharp 2 Current XA MPR VRT MPR MIP MPR Unknown study description Compare RPH Favorite Tools 30 nG fix T Foot_HD_1 ... 10cm 10cm 10cm Series AFF Parallel Radial Curved Multitom RAX 30 Favorite Tools × Preview 01011900 CURRENT Preset Select the Preset 30 nG fix T_Foot_HD_16 sharp 2 Distance ROI Circle 2 Image Thickness 0,5 mm Distance between Images 0,5 mm Printing Number of Images 205 Field of View 204,8 = x 204,8 mm 5b Paratel Presets Orientation Image Series 716 Start Accept Close 08:12 Parallel Radial Curved Spine * Vascular Preset Select the Preset Image Thickness 0.3 mm Distance between Images 0.3 mm Number of Images 256 + Field of View 176.0 = x 176.0 + mm 5b Presets Orientation Image Series Complete Complete Coronal Complete create Axial Sagittal Preset Start Accept Close Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Page 4 of 8 Job Aid | How to Create Ranges Effective Date: 8/25/2020 | HOOD05162003114147 6. Click the Start button to start range reconstruction. Parallel Radial Curved Spine * Vascular Preset Select the Preset Image Thickness 0.3 mm Distance between Images 0.3 mm Number of Images 256 Field of View 176.0 ¢ x 176.0 ¢ mm Presets Orientation Image Series Complete Complete Coronal stheral preget Create Axial 6 Start Accept Close 7. A Range Series Name and Image comment can be added. 8. Select the Accept button to save the range output. Parallel Radial Curved Preset Select the Preset Image Thickness 0,5 mm Distance between Images 0,5 mm Number of Images 205 Field of View 204,8 204,8 + mm Presets Orientation Image Series Range Series Name MPR 0.5mm Range Image Comment Include Reference Image 8 Reject Accept Close Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Page 5 of 8 Job Aid | How to Create Ranges Effective Date: 8/25/2020 | HOOD05162003114147 9. The range series is saved as a result series on the Series panel, which is indicated by an icon next to the series name. FR HL Series X Multitom RAX 3D 01011900 CURRENT 3D nG fix T_Foot_HD_16 sharp 2 Current 2. XA Unknown study description 3D nG fix 10cm 10cm 477 9 476 . MPR 0.5mm Range Parallel Radial Curved Preset Select the Preset Image Thickness 0,5 mm Distance between Images 0,5 mm Number of Images 205 Field of View 204,8 + x 204,8 + mm Presets Orientation Image Series Range Series Name MPR 0.5mm Range[2] Image Comment Include Reference Image Start Accept Close Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Page 6 of 8 Job Aid | How to Create Ranges Effective Date: 8/25/2020 | HOOD05162003114147 10. To view a created range series, double-click it on the Series panel (10a). A floating window will open (10b). The first image in this window will show you the overview of the created range. Within the floating window, scroll through the images with the middle mouse button/mouse wheel. This will show you the single range series images (10c). Syngo2 ? HZ O MUITOm FAR So * 01/01/1900 M 01011900 Viewin AFR Series MPR 0.5mm Range Multitom RAX 3D ? X Multitom RAX 3D 01011900 Viewing CURRENT CURRENT Multitom RAX 3D HAR 30 nG fix T_Foot_HD_16 sharp 2 3D nG foc T_Foot_HD_16 sharp 2 01011900 syngo via viamens Current 2 MPR VRT 01/01/1900, M, 120Y HES XA Unknown study description 28/01/2020 LLS MPR 0.5mm Range 1 6:47:55.02 A Favorite Tools MPR THICK MAO 10b 10a BP P59,6 10cm 477 MPRS Series Parallel {} Radial Curved Favorit Preset Select the Preset Distance between Images 0.5 mm Slice Thickness: 0,5 mm A Image Thickness 0,5 + mm V 80,9 Distance between Images 0,5 mm Printing SL 0,5 ₩ 2988 Number of Images 205 Field of View 182,0 x 182,0 mm Windowing O. Presets Orientation Image Series Range Series Name |MPR 0.5mm Range[2] Image Comment Include Reference Image Start Accept Close 08:16 leolthineers› Syngo2 Multitom RAX 3D * 01/01/1900 M 01011900 Viewi AER Series MPR 0.5mm Range ? > Multitom RAX 30 Multitom RAX 3D 01011900 Viewing Stack 3x CURRENT CURRENT Multitom RAX 3D AFR Siemens- 30 nG fix T_Foot_HD_16 sharp 2 3D nG for T_Foot_HD_16 sharp 2 Current 01011900 syngo.via ViewAndGO "01/01/1900, M, 120Y XA MPR VR 28/01/2020 Unknown study description MPR 0.5mm Range 16:47:55.02 Favorite Tools MPR THICK 10c IMA 44 SP H207.3 POING Fox Jocm 0000 RH 477 477 Series & MPR.0.5mm Parallel Radial Curved Favor Preset Select the Preset Image Thickness 0,5 mm KV 80,9 Printing - 8 SL 0,5 Distance between Images 0,5 mm Number of Images 205 Field of View 182,0 x 182,0 mm Windowins Presets Orientation Image Series Range Series Name |MPR 0.5mm Range[2] Image Comment Include Reference Image Start Accept Close 08 : 19 Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Page 7 of 8 Job Aid | How to Create Ranges Effective Date: 8/25/2020 | HOOD05162003114147 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens-healthineers.com Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Page 8 of 8
- Multitom RAX
- Syngo.via View&GO