PEPconnect

syngo.via View&GO: Workflow

This job aid will cover the workflow on the workstation.

syngo.via View&GO: Plugin Workflow XPRF This document guides you through the reprocessing workflow for X-ray 2D projection images as available for the Multitom Rax in syngo.via View&GO. In easy steps, you will learn how to reprocess suitable X-ray 2D projection images into 3D volume image data sets for further evaluation. Reprocessing X-ray Projection Images into a 3D Volume Step 1 In the Patient Browser, select a patient containing a series with an X-ray 2D projection image set and double-click the left mouse button to load the patient data into the Viewer. Patient Browser Search By Name ID Date Dochption and Modality (Coil+F) Q Results (3 results, 14:34:07) Series netality Multitom RAX 3D 01/01/1900 01011900 XA 28/01/2020 1 ... 00 SITA all Syngo, Validation Test 16 . CT. OT, PR 19/02/2018 1 Syngo Valida T Fad HD_18 Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Master Template Effective Date: 3/11/2019 | HOOD05162002998095 SIEMENS Job Aid Effective Date: 8/31/2020 | HOOD05162003114140 Healthineers Job Aid | XP Plugin Workflow Effective Date: 8/31/2020 | HOOD05162003114140 Step 2 The 2D projection image data appear in the Image Viewer, and reprocessing starts automatically indicated by a progress bar at the bottom of the patient tab. Multitom RAX 3D X * 01/01/1900 M 01011900 Multitom RAX 3D 01011900 CURRENT 3DnG fix [email protected] 28/01/2020 16:47:55 Please drag data from Series Navigator. 10em Zoom 0,33 142 Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Page 2 of 8 Job Aid | XP Plugin Workflow Effective Date: 8/31/2020 | HOOD05162003114140 Step 3 1. Once the reprocessing is finished as indicated by a dialog box and confirmed by clicking OK,… 2. … the Image Viewer shows the reprocessed 3D volume next to the 2D projection image. The 2D projection data set was reprocessed with a parameter setup that was predefined within the OGP (Organ Program) database. In this example the setup “Sharp” was used. Please note: The reproccesed 3D volume series appears in the Viewer for further evaluation, for example in the image mode MPR (Multi Planar Reconstruction). Multitom RAX 3D × * 01/01/1900 M 01011900 A Multitom RAX 3D Multitom RAX 3D 01011900 01011900 CURRENT CURRENT 3D ne fix T_Foot_HD_16-0 3D nG fix T_Foot HD_16 sharp 2 28/01/2020 16:47:55 2 o o R 10cm X-Ray Reprocessing AF X Zoom 0,91 512 i Reprocessing successfully finalized. 1 OK Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Page 3 of 8 Job Aid | XP Plugin Workflow Effective Date: 8/31/2020 | HOOD05162003114140 Step 4 In the Patient Browser view, the newly reprocessed 3D volume image series appears as a series icon in addition to the 2D projection series. SIEMENS Healthineers Multitom RAX 3D X Patient Browser Search by Name, ID, Date, Description and Modality (Ctrl+F) Q Results (3 results, 14:46:01) Series Patient Name Date of Birth Patient ID Modality Study Date a. Study Descript. Multitom RAX 3D 01/01/1900 01011900 XA 28/01/2020 1 00_SITA_all Multitom RAX Full Body 29/11/1991 3456 XA 29/11/2019 1 00 mh Syngo, Validation Test 19/02/1963 18.02.19-15: CT, OT, PR 19/02/2018 1 Syngo Valida Foot_HD_16 sh ... T_Foot_HD_16 Please note: 3D reprocessing only starts automatically, if you load just one 2D projection data series into the Viewer. Automatic 3D reprocessing is not started, if you load the entire patient at once which might include multiple data sets. If the result images do not meet your requirements, you can adjust the reprocessing parameters by repeating the reprocessing as described below: Step 5 In the Patient Browser, select a patient containing a series with a 2D projection image series for 3D volume reprocessing and double-click the left mouse button to load the patient data into the Viewer. SIEMENS Healthineers Multitom RAX 3D X Patient Browser Search by Name, ID, Date, Description and Modality (Ctrl+F) Q Results (3 results, 14:46:01) Series Patient Name Date of Birth Patient ID Modalit Study Date a Study Descript. Multitom RAX 3D 01/01/1900 01011900 XA 28/01/2020 1 00 SITA all Multitom RAX Full Body 29/11/1991 3456 XA 29/11/2019 1 00 mh Syngo, Validation Test 19/02/1963 18.02.10 CT, OT, PR 19/02/2018 1 Syngo Valida T_Foot_HD_16 sh .. 3D nG fix T_Foot_HD_16 Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Page 4 of 8 Job Aid | XP Plugin Workflow Effective Date: 8/31/2020 | HOOD05162003114140 Step 6 1. The 2D projection image series appears in the Viewer. 2. Click the image segment to activate it. A blue frame around the segment gets visible. 3. In Favorite Tools, the Reprocessing function gets available (its icon changes from greyed out to bright). Multitom RAX 3D * 01/01/1900 M 01011900 Viewing X Multitom RAX 3D 01011900 Stack 3x2 Stack 4x4 Follow Up 2TP 2X2 CURRENT SD nG fix T_Foot_HD_16-0 28/01/2020 16:47:55 MPR VRT MPR MIP MPR Compare 2 10cm Zoom 0,33 1420 Favorite Tools X O Distance ROI Circle Custom Line Text Snapshot 3 Repro- Windowing cessing Step 7 In Favorite Tools, click the Reprocessing icon to activate it. Repro- cessing Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Page 5 of 8 Job Aid | XP Plugin Workflow Effective Date: 8/31/2020 | HOOD05162003114140 Step 8 The X-Ray Reprocessing window opens. X-Ray Reprocessing ? X Select one image impression for the reprocessing: Smooth Medium Sharp Smooth (Metal Artifact Reduction enabled) Medium (Metal Artifact Reduction enabled) Sharp (Metal Artifact Reduction enabled) Ok Cancel Select a different image impression parameter and click OK. The window closes, and a new reprocessing starts according to the selected image impression. X-Ray Reprocessing ? × Select one image impression for the reprocessing: Smooth Medium Sharp Smooth (Metal Artifact Reduction enabled) Medium (Metal Artifact Reduction enabled) Sharp (Metal Artifact Reduction enabled) Ok Cancel Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Page 6 of 8 Job Aid | XP Plugin Workflow Effective Date: 8/31/2020 | HOOD05162003114140 Step 9 1. Once the reprocessing is finished as indicated by a dialog box and confirmed by clicking OK,… 2. … now the first and the second reproccesed 3D volume series appear in the Viewer for further evaluation. The 2D projection data set was reprocessed a second time, in this case with a “Medium” parameter setup. Please note: The second reprocessed 3D volume series in the Viewer may now be evaluated, for example in the image mode MPR (Multi Planar Reconstruction). Multitom RAX 3D X * 01/01/1900 M 01011900 Multitom RAX 3D Multitom RAX 3D Multitom RAX 3D 01011900 01011900 01011900 CURRENT CURRENT CURRENT 3D nG fix T_Foot HD_16-0 3D nG fix T_Foot_HD_16 medium 2 3D n$ fix T_Foot_HD_16 sharp 2 28/01/2020 16:47:55 R 2 X-Ray Reprocessing AF X i Reprocessing successfully finalized. Zoom 0,9 512 oom 0,94 512 1 OK Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Page 7 of 8 Job Aid | XP Plugin Workflow Effective Date: 8/31/2020 | HOOD05162003114140 For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information li ke warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens-healthineers.com Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Page 8 of 8