syngo.via CT Cardiac Function

syngo.via CT Cardiac Function

syngo.via® CT Cardiac Function syngo.via CT Cardiac Function is designed to aid in the diagnostic evaluation of cardiac CT angiography (CTA) multi-phase volume data sets, specifically in the assessment of the right and left ventricles for cardiomyopa-thy. 1. From the Patient Worklist, load an appropriate data set into the CT Cardiac Function Workflow: • If the examination has been correctly mapped, double click to load • If manual mapping is required, right-click the examination and select Open With > CT Cardiac Function 2. Use the Phase Navigator to review different phases in a multi-phase car- 80% 256 * 256 diac data set. Select a phase directly from the list, use the mouse (scroll 10% 256 * 256 wheel + ALT, or drag left/right + RMB) or up/down arrows to step through 20% 256 * 256 35% 256 * 256 consecutive phases. The cine mode will automatically navigate through 45% 256 * 256 50% 256 * 256 all available cardiac phases. The automatic loading strategy utilizes 55% 256 * 256 Best Diastole/70% R – R, or that phase which is closest. 60% 256 * 256 65% 256 * 256 70% 256 * 256 71% BestDiast 512 * 512 3. Review the preprocessing results. If needed, modify the heart chamber 75% 256 * 256 segmentation. 80% 256 * 256 • Display contour lines – in the Case Navigator, enable the Show Contours icon and evaluate the preprocessed contours Show  Red = LV endocardium, green = LV epicardium Contours  Yellow = RV • Manually initialize heart chamber segmentation – in some instances of complex pathological anatomy, the automatic segmentation may fail. In the Case Navigator, Initialize enable the Initialize Manually icon. Using the provided graphic as a guide, click to Manually identify two LV base points and the LV apex point. Chamber contours are recalcu- lated. Please set the LV apex port Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 4/28/2017| HOOD05162002591125 Healthineers Job Aid | syngo.via CT Cardiac Function Effective Date: 4/28/2017| HOOD05162002591125 • Edit contours – in the Case Navigator, enable the Edit Contours icon. The contour edit mini toolbar is displayed. Edit Contours Show/Hide Range Default Zoom Pan Edit LV Edit LV Edit RV Septum Draw Endo Epi Contour Point Contours  Click the icon of the contour to be modified. The chosen contour will highlight magenta  Click the magenta colored contour at the point where you want to start the modification  Drag the mouse pointer to define a new contour  Double click to end the new contour drawing Show/Hide Range Default Zoom Pan Edit LV Edit LV Edit RV Septum Endo Epi Contour Point 4. To better assess myocardial movement or the function of the aortic and mitral valves, MPR views can be aligned with the cardiac or valve planes. • In the Case Navigator, enable the Cardiac Planes icon. Cardiac Planes • syngo.via calculates the orientation of the standard cardiac planes on the best dias- tolic phase or that phase closest to 70%. • In the Case Navigator, enable the Aortic Valve Plane or Mitral Valve Plane icon Aortic Valve • syngo.via calculates the orientation in alignment with the selected valve Mitral Valve Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 4/28/2017| HOOD05162002591125 Healthineers Page 2 of 6 Job Aid | syngo.via CT Cardiac Function Effective Date: 4/28/2017| HOOD05162002591125 5. Functional analysis of the left ventricle (LV) – including ejection fraction, stroke volume, and wall mo- tion - can be accomplished through either the Standard Mode or the Blood Volume Mode  The default Standard Mode calculates the LV volume within the red contour to include the papillary muscles and also uses a straight mitral valve plane.  The Blood Volume Mode calculates the LV volume indicated by the pink over- lay to exclude the papillary muscles and includes the aortic outflow tract by using an anatomically modeled valve plane.  On the Left Ventricular Analysis step, enable the Blood Volume Mode icon. • The LV Blood Volume can be edited to include or exclude more or less blood pool using the Blood Pool Threshold mini tool bar Blood Pool Threshold SHU -100 400 242 HU Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 4/28/2017| HOOD05162002591125 Healthineers Page 3 of 6 Job Aid | syngo.via CT Cardiac Function Effective Date: 4/28/2017| HOOD05162002591125 6. Global cardiac parameters are displayed in the Numerical Results Table with both Standard Values (default) and Indexed Values. Standard Values Indexed Values Indexed values are normalized with re- Standard Mode LV Normal Values spect to body surface area (BSA) so can Ejection Fraction 1% 56 - 78 only be calculated if the patient’s height Myocardial Mass ED 9 ₿5.63 75 - 175 Stroke Volume 0.15 35 and weight are available. If not pro- 33 - 97 vided during patient registration, double ED Volume ml 29 27 58 - 154 click a “ - ” value on the Indexed Value ES Volume ml 29.12 13 - 51 Cursor Volume ml 29.27 tab and enter manually. Cardiac Output (l/min) 0.01 2.65 - 5.98 Height: 62 cm 5 ft 3 in Sex: Female Weight: 74 kg 163 lbs BSA / m2 1.82 7. Functional analysis of the right ventricle (RV) can be displayed independently or in conjunction with the LV. Left Ventricular Analysis Right Ventricular Analysis Shows LV function results. Standard Mode ES (RV) 128.61 ml ED INVI RV LV 20% 30% 40% 70% 80% 90% RAH 105ms 211ms 316ms 422ms 527me 632ms 738ms 843ms 949m Standard Values Indexed Values Standard Mode LV RV Normal Values Ejection Fraction Myocardial Mass ED 274.04 38 30 Stroke Volume 126.55 79.74 MPR ED Volume 171.59 208.35 ES Volume 45.04 128.61 LAO 87 Cursor Volume 160.76 188.72 CRAN 61 Cardiac Output 7.09 Height: kg in Others Weight: Sex: BSA/ m2 Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 4/28/2017| HOOD05162002591125 Healthineers Page 4 of 6 Job Aid | syngo.via CT Cardiac Function Effective Date: 4/28/2017| HOOD05162002591125 8. The Perfusion Evaluation step automatically displays enhancement in the long and short axes, polar maps, and 3D volume images. Right Ventricular Analysis PRA PRH PRA Perfusion Evaluation 6.1 ,2 RAH RAH Compute Edit Mask Maps 0.00 Enhancement Enhancement Mask 4,1,3 6,1,3 RAH RAH RAH 0.00 75% Phase , HU 70% Phase Standard Mode 10.00 6 RFA 0.00 Wall Motio Standard Mode 100.00 0.00 0.00 Wall Thickening B26_0.75mm 10-100% 4 0.00 Wall Thickness 70% Phase / mm Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 4/28/2017| HOOD05162002591125 Healthineers Page 5 of 6 Job Aid | syngo.via CT Cardiac Function Effective Date: 4/28/2017| HOOD05162002591125 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 4/28/2017| HOOD05162002591125 Healthineers Page 6 of 6