syngo.via VB40 Delta - General Enhancements & Improvements - USA
This online training is intended to train you on enhancements and improvements of the syngo.via VB40 software.
Upon successful completion of this online training, you will know about: General improvements and enhancements of the syngo.via VB40 software version concerning: Removed confirmation dialog when discarding a workflow Hide reference lines during scrolling Series Navigator Findings Assistant syngo.via WebViewer conferencing capability Please note: Some of the features are license dependent. Congratulations. You have completed the syngo.via VB40 Delta online training - General Enhancements & Improvements. Listed below are the key points that have been presented. Take time to review the material before you proceed to the final quiz. Select the link below to view and/or print your review material before proceeding to the final quiz. Download and print a copy of the Course Review. General Enhancements & Improvements of the syngo.via VB40 Software Version When you discard an open workflow by selecting ‘Discard changes’ in the Close Patient Dialog box, the workflow is now closed immediately. No additional dialog is shown. The Reference Lines are automatically hidden in the segment scrolling with the right mouse button. A few improvements have been done to the Series Navigator. Firstly, the series number can now be displayed. Secondly, quick and easy access of the result series created on syngo.via is now possible: they are now displayed together with the corresponding time point and indicated by an icon. The Findings Assistant now allows you to cluster your findings according to body regions or organs and add general information on those. Each body region presents specific fields for standardized report information creation and includes automatic features like RAD score calculation. New reporting guidelines enhance documentation and communication of results: Besides BI-RADS and PI-RADS, guidelines for Lung-RADS Screening and Lung Cancer TNM Staging, LI-RADS and CAD-RADS are included. New design allows you to export measurements and other attributes available in the Findings Assistant directly to PDF, email, or copy and paste it to your dictated report. The syngo.via WebViewer now allows you to do a remote conference, sharing your screen with other users. Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. The information in this material contains general technical descriptions of specifications and options as well as standard and optional features that do not always have to be present in individual cases. Certain products, product related claims or functionalities described in the material (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH, 2019 Images courtesy of: Erasmus Medical Center, Department of Radiology, Rotterdam, The Netherlands Institut Jules Bordet, Department of Radiology, Bruxelles/Brussels, Belgium Kantonsspital Münsterlingen, Department of Radiology, Münsterlingen, Switzerland Klinikum der Ludwig-Maximilians-Universität, Department of Radiology, Munich, Germany Universitätsklinikum Tübingen, Department of Radiology, Tübingen, Germany Welcome to the syngo.via VB40 delta online training. In this training you will learn about general enhancements and improvements that are available with the syngo.via VB40 software version. For further enhancements of MM Reading within the syngo.via VB40 software version, such as syngo.via OpenApps, Advanced Visualization Tools, Interactive Spectral Imaging and MR General Tools, please see the corresponding delta online trainings part 1 and part 2 in the syngo.via training area of PEPconnect. This chapter introduces the following general enhancements and improvements that are available with the syngo.via VB40 software version: Removed confirmation dialog when discarding a workflow Hide reference lines during scrolling Series Navigator Findings Assistant syngo.via WebViewer conferencing capability When you discard an open workflow by selecting ‘Discard changes’ in the Close Patient Dialog box, the workflow is now closed immediately. The additional ‘Discard confirmation’ dialog is no longer shown as in previous syngo.via versions. In order to not cover image information during reading, the Reference Lines are automatically hidden in the segment while scrolling with the right mouse button. The syngo.via WebViewer is a zero footprint software-only solution for reviewing medical images from syngo.via for diagnostic use. In addition to your syngo.via, you have remote access to images for example on an iPad or any web browser to support interpretation and evaluation of examinations. The syngo.via WebViewer now allows you to do a remote conference, sharing your screen with other users. You can invite other users or join conferences upon invitation. An interactive marker is available to highlight regions of interest. *The application syngo.via WebViewer is not for diagnostic viewing/reading on mobile devices in the US. Diagnostic reading of images with a web browser requires a medical grade monitor. For iPhone and iPad country specific laws may apply. Applications on iPhone / iPad / iPod are not a medical device in Japan. Use at your own risk. They are not intended to be used for diagnosis. This chapter introduces the following improvements of the Series Navigator that are available with the syngo.via VB40 software version: Series number Result series display The Series Navigator gives an overview of the series loaded and groups this data according to specific criteria. In addition to the series name, you can now visualize the series number in a dedicated column in the list view. The display of the series number can be configured by performing a right mouse button click on the column header. The selection is persistent per user and is valid across the workflows. For quick and easy access of the result series created on syngo.via, they are now displayed together with the corresponding time point in the Series Navigator. A ‘user created’ icon is added for easy identification of results created on a series such as parallel ranges and snapshots. This user created icon will remain displayed in the section until the user completes the workflow. If the workflow is paused then the user icon is visible. This chapter introduces the following improvements of the Findings Assistant that are available with the syngo.via VB40 software version: Body regions Guidelines overview LungRADS Screening example Reporting Direct export Configuration The Findings Assistant now allows you to cluster your findings according to body regions or organs. Specific fields for standardized report information creation and automatic features are also provided. This organization of findings is reflected in the structured report as well. New reporting guidelines enhance documentation, harmonization and communication of results. LungRADS Screening, Lung Cancer TNM Staging, LI-RADS and CAD-RADS are now available in addition to PI-RADS and BI-RADS. The Findings Assistant guides you through the measurement and provides automatically calculated results. To complement your reading, you can evaluate additional body parts and document the results easily using the Findings Assistant. Let's see the following example. For reading your CT Lung case, First select the body region ‘Lung’. Choose the LungRADS Screening Finding Type as a next step. The system then guides you on which measurements need to be performed. You can add additional information like Location, Organ Segment, and more. The LungRADS score, mean value and growth will be automatically calculated.You could add further comments on the additional body part ‘Thorax’ for example. For each of the new and existing guidelines integrated in the Findings Assistant, the system calculates the RAD score, TNM and other measurements automatically. The guidelines are also available for consultation on our help menu. The structured organization of findings you find in the Findings Assistant is automatically taken over to your Structured Report as well. Exporting measurements as PDF, email or copy and paste to a dictated report can be directly done out of the Findings Navigator. The Reporting Section of the Configuration Panel allows you to directly start evaluating dedicated body regions by automatically adding default reporting groups that will be shown in the Findings Assistant after opening a corresponding case.
- syngo.via
- VB40
- Delta
- syngovia
- snygo
- via