syngo.via_Comparing Studies_MM Reading
syngo.via_Comparing Studies_MM Reading
syngo.via - How To Compare Two Studies MM Reading 1. From the Results List within the Patient Navigator, double-click on the most recent patient study. 2. Select the Add Study button in the series Navigator. SIEMENS VIAOB Technolo ... AS+_Lung_Multiven ... Female x MM Reading 5/22/1953 ONCOLOGY MM Reading Data Groups -AS+_Lung_Multivendor_GE, France SCANNER ST GATEN *5/22/1953, F. 55Y Ref: Onco Gold io MM Reading CURRENT Definition AS+ Thorax 1.0 B411 [2] CT 2003G 6/1 0/2008 Current Add Study 8:57:02.97 AM CT, 6/10/2008 SP H1274.6 Follow up Siemens Overview LCAD_Thorax 1.0 B70f [3] Compare * Thorax 1.0 B41f [2] Results O F SL 0.5 MPR THICK 350 50 =AS+_Lung_Multivendor_GE, France CAN piet: Onco Com 15/22/1 953, F, 55Y CURRENT Thorax 1.0 B41f [2] 6/10/2008 8:57:02.97 AM SP A134.2 Findings Navigator MPR THICK -AS+_Lung_Multivendor_GE, France SCANNER ST GATEN .5/22/1953, F. 55Y CURRENT Thorax 1.0 B411 [2] 6/1 0/2008 8:57:02.97 AM SP R6.0 9:21 AM MPR THICK Find Start 100% 3. Double-click on the study to use for comparison. The study will then be displayed withing the Series Navigator. Add Study ? × AS+_Lung_Multivendor_GE, France, 5/22/1953, ONCOLOGY Study Description Study Date and Time Modality Baseline GE 2/20/2008 1:51:40 PM CT, SR 05-Feb-2003_@ 2/5/2003 9:40:09 AM CT 23-Oct-2002_@ 10/23/2002 8:41:45 AM SEG, SR Thorax Combi 1/30/2001 2:04:31 PM CT Studies added Refresh Add Study 4. Expand both studies to view the series. 5. Right-click on the desired prior series then drag to the Viewer. Add Series 5C IF Replace all Series SL 0. Add as Fused (MPR/MPR) SIEMENS www.usa.siemens.com/healthcare 757 Effective date 9/8/2016 Page 1 of 3 6. Click the Add Series option. Both series’ should now be displayed. SIEMENS VIAOS Server: TDCVIAOS Assign Technolo. Referring ASt Lung Multiven. Female MM Reading 5/22/1953 ONCOLOGY MM Reading Data Groups =AS+_Lung_Multivendor_GE, France SCANNER ST GATIEN =AS+_Lung_Multivendor_GE, France SCANNER POLE SANT. *5/22/1953, F.557 Ref : Onco Gold *5/22/1953, F, 54Y Ref.: Onco Gold MM Reading CURRENT Definition AS+ Prior 01 LightSpeed Pro 32 Thorax 1 0 B41f [2] CT 2008G CD MEDIASTIN AXIAL [N601] Current 6/10/2008 2/20/2008 CT, 6/10/2008 Follow up Siemens Overview LCAD_Thorax 1.0 B70f [3] Compare * Thorax 1.0 B41f [2] Results F Prior 01 ! CT, 2/20/2008 SL 0.6 Baseline GE PR THICK 350 50 ! Results MM Oncology Readin ... ! CD MEDIASTIN AXIAL [N601] ! LCAD_PARENCHYME [N4] PsRang po gold 11 121 N AXIAL IN501) SPA134 2/20/200 Findings Navigator MPR THICK MPR THICK L2VOM 54.43 ... MMOn ... [CT & 0 =AS+ Lung_Multivendor SCANNER ST GATIEN =AS+ Lung_Multiven *5/22/1953, F, 55Y Ref: Onco Gold *5/22/1953, F, 54Y CURRENT Definition AS+ Prior 01 Thorax 1.0 B41f [2] Cf 20080 CD MEDIASTIN AMAL [ 6/10/2008 2/20/2008 8:57:02.97 AM 1:54:54.00 PM SP R6.0 SP R12.0 5cm L SL 0.5 MPR THICK 350 50 MPR THICK 9:24 AM Find Start 7. To view the two series in a larger format, right-click on a segment then select Enlarge Orientation. Distance Line 1:54:54 SP F1 o- Windowing R Paste Meagine ent Som F Enlarge Series SL 0.5 THICK Enlarge Orientation MPR TH 50 Exclude Series 8. To adjust slice synchronization, press the Ctrl key + Shift key while rolling the mouse wheel. SIEMENS www.usa.siemens.com/healthcare Page 2 of 3 On account of certain regional limitations of Local Contact Information sales rights and service availability, we cannot guarantee that all products included in this Siemens Medical Solutions USA, Inc. brochure are available through the Siemens 51 Valley Stream Parkway sales organization worldwide. Availability and Malvern, PA 19355-1406 packaging may vary by country and is subject USA to change without prior notice. Some/All of the Phone: +1-888-826-9702 features and products described herein may not www.usa.siemens.com/healthcare be available in the United States. The information in this document contains Global Business Unit general technical descriptions of specifications and options as well as standard and optional Siemens AG features which do not always have to be present Medical Solutions in individual cases. SYNGO Products Henkestr. 127 Siemens reserves the right to modify the design, DE-91052 Erlangen packaging, specifications and options described Germany herein without prior notice. Please contact your Phone: +49 9131 84-0 local Siemens sales representative for the most www.siemens.com/healthcare current information. Note: Any technical data contained in this document may vary within defined tolerances. Original images always lose a certain amount of detail when reproduced. Global Siemens Headquarters Global Siemens Legal Manufacturer Healthcare Headquarters Siemens AG Siemens AG Wittelsbacherplatz 2 Siemens AG Wittelsbacherplatz 2 80333 Muenchen Healthcare Sector DE-80333 Muenchen Germany Henkestrasse 127 Germany 91052 Erlangen Germany Phone: +49 9131 84-0 www.siemens.com/healthcare www.siemens.com/healthcare 1 All rights reserved | © 2015 Siemens Medical Solutions USA, Inc.
- syngo.via