Sysmex® CA-500 Series System Competency Checklist
Education resource material designed to document competency mastery on-the-job. This Competency Checklist represents all learning objectives for this training area.
Sysmex® CA-500 Series System Competency Checklist Once an employee has acquired the necessary knowledge and skills to perform basic operation tasks this checklist can be used to observe the employee perform the required tasks for their core job responsibilities and to document demonstrated competency. The observer places their initials and date beside the task when it is performed successfully. Successful completion for each task is determined by the facility. The standards used to evaluate can be documented in the “Criteria” section below. Use the area on the last page to record comments or areas of improvement. If necessary, the observer can record recommended next steps of action for areas of improvement or development opportunities. When all required tasks are completed, the supervisor and employee sign and date this document as a record of completion. Criteria - Standards for successful completion of each task (e.g. Accuracy, Time, Quality, etc.): Observer’s Initials and Completion Date Topic/Tasks System Overview Identify and name a function of the external components Identify and name a function of the internal components Locate and identify the areas of the Main menu screen Sample Processing Identify sample processing areas of the Main Menu screen Perform sample processing Locate results in Stored Data screen Reagent Management Locate reagent information Identify the Siemens reagent vial types Identify reagent positions Perform daily reagent setup tasks Coagulation Curve Theory Identify key areas of the Stored Data graphic display screen Identify the coagulation curve components Distinguish between a normal and an abnormal coagulation curve Calibration Identify key areas of the Standard Curve screen Perform a Standard Curve calibration Execute the steps to manually enter data in a standard curve Quality Control Process a Quality Control Sample Identify key areas of the QC screen Perform the steps to print QC data Identify data on the QC printouts Daily/Weekly Maintenance Perform daily maintenance Perform weekly maintenance Other Maintenance Perform Quarterly maintenance Perform As Needed maintenance Quality # HILS1906 Effective Date: 06/09/2017 Page 1 of 2 SIEMENS siemens.com/healthineers Healthineers Sysmex® CA-500 Series System Competency Checklist Comments Areas of Improvement Next Steps Primary Operator Secondary Operator has been trained on the above documented tasks Supervisor: Employee: Date: Quality # HILS1906 Effective Date: 06/09/2017 Page 2 of 2 SIEMENS siemens.com/healthineers Healthineers
- sismex
- sysnex